Cargando…

Recovery of LHCb Detector Muon Chambers for Malter Effect Elimination

A method is presented for restoring the performance of gas discharge detectors wherein a spontaneous self-sustaining current, i.e., Malter effect, occurs. A successful practical implementation of the method is demonstrated by the example of recovery of operability for multiwire proportional chambers...

Descripción completa

Detalles Bibliográficos
Autores principales: Gavrilov, G E, Maev, O E, Maisuzenko, D A, Nasybulin, S A
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1134/S1063778819090059
http://cds.cern.ch/record/2725309
_version_ 1780966018305228800
author Gavrilov, G E
Maev, O E
Maisuzenko, D A
Nasybulin, S A
author_facet Gavrilov, G E
Maev, O E
Maisuzenko, D A
Nasybulin, S A
author_sort Gavrilov, G E
collection CERN
description A method is presented for restoring the performance of gas discharge detectors wherein a spontaneous self-sustaining current, i.e., Malter effect, occurs. A successful practical implementation of the method is demonstrated by the example of recovery of operability for multiwire proportional chambers used in the muon detector of the LHCb experiment carried out at the Large Hadron Collider. Four proportional chambers wherein Malter currents regularly occur during the experiment were subjected to high-voltage discharge training in the working gas mixture of 40% Ar + 55% CO$_{2}$ + 5% CF$_{4}$ with 2% of oxygen added. It is shown that, with addition of oxygen, the recovery of the proportional chambers occurs tens of times faster in compare to the training in the working gas mixture. The reconstructed chambers were installed in the LHCb muon detector and have been working in a collider beam experiment for more than two years already.
id oai-inspirehep.net-1788078
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling oai-inspirehep.net-17880782020-07-29T21:30:49Zdoi:10.1134/S1063778819090059http://cds.cern.ch/record/2725309engGavrilov, G EMaev, O EMaisuzenko, D ANasybulin, S ARecovery of LHCb Detector Muon Chambers for Malter Effect EliminationDetectors and Experimental TechniquesA method is presented for restoring the performance of gas discharge detectors wherein a spontaneous self-sustaining current, i.e., Malter effect, occurs. A successful practical implementation of the method is demonstrated by the example of recovery of operability for multiwire proportional chambers used in the muon detector of the LHCb experiment carried out at the Large Hadron Collider. Four proportional chambers wherein Malter currents regularly occur during the experiment were subjected to high-voltage discharge training in the working gas mixture of 40% Ar + 55% CO$_{2}$ + 5% CF$_{4}$ with 2% of oxygen added. It is shown that, with addition of oxygen, the recovery of the proportional chambers occurs tens of times faster in compare to the training in the working gas mixture. The reconstructed chambers were installed in the LHCb muon detector and have been working in a collider beam experiment for more than two years already.oai:inspirehep.net:17880782020
spellingShingle Detectors and Experimental Techniques
Gavrilov, G E
Maev, O E
Maisuzenko, D A
Nasybulin, S A
Recovery of LHCb Detector Muon Chambers for Malter Effect Elimination
title Recovery of LHCb Detector Muon Chambers for Malter Effect Elimination
title_full Recovery of LHCb Detector Muon Chambers for Malter Effect Elimination
title_fullStr Recovery of LHCb Detector Muon Chambers for Malter Effect Elimination
title_full_unstemmed Recovery of LHCb Detector Muon Chambers for Malter Effect Elimination
title_short Recovery of LHCb Detector Muon Chambers for Malter Effect Elimination
title_sort recovery of lhcb detector muon chambers for malter effect elimination
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1134/S1063778819090059
http://cds.cern.ch/record/2725309
work_keys_str_mv AT gavrilovge recoveryoflhcbdetectormuonchambersformaltereffectelimination
AT maevoe recoveryoflhcbdetectormuonchambersformaltereffectelimination
AT maisuzenkoda recoveryoflhcbdetectormuonchambersformaltereffectelimination
AT nasybulinsa recoveryoflhcbdetectormuonchambersformaltereffectelimination