Cargando…

Preliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide Study

In the framework of a world-wide international collaboration, the FCC-hh, a 100 TeV hadron collider in a 100-km long tunnel, is proposed as a future circular collider beyond LHC at CERN offering the broadest discovery potential at the energy frontier. For such high performance hadron collider, the c...

Descripción completa

Detalles Bibliográficos
Autores principales: Tavian, L, Millet, F, Roig, M, Zick, G, Bernhardt, JM
Lenguaje:eng
Publicado: IOP 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1757-899X/755/1/012085
http://cds.cern.ch/record/2725610
_version_ 1780966041290014720
author Tavian, L
Millet, F
Roig, M
Zick, G
Bernhardt, JM
author_facet Tavian, L
Millet, F
Roig, M
Zick, G
Bernhardt, JM
author_sort Tavian, L
collection CERN
description In the framework of a world-wide international collaboration, the FCC-hh, a 100 TeV hadron collider in a 100-km long tunnel, is proposed as a future circular collider beyond LHC at CERN offering the broadest discovery potential at the energy frontier. For such high performance hadron collider, the cryogenic system has to distribute very large cooling capacities all along the 100-km tunnel for the superconducting magnets continuously cooled at 1.9 K and for the beam screens operated between 40 and 60 K. The required total cooling power will be produced in 10 refrigeration plants with a unit equivalent capacity of 100 kW at 4.5 K, up to 4 times larger than the present state-of-the-art. Half of the entropic refrigeration load is due to the synchrotron radiation produced by the high-energy proton beams and deposited on beam screens actively cooled around 50 K. This non-conventional thermal load distribution is an additional challenge for the FCC-hh cryogenic system. Furthermore, the cryogenic system has to cool down the cold mass of the FCC-hh machine in less than 20 days with controlled thermal gradients in the cryo-magnets and beam screens. Based on preliminary design works from research institutes, an engineering study was performed with world-leader industries to assess a preliminary conceptual design for the FCC-hh cryogenic plants with industrial solutions and innovative technologies. The present paper recalls the FCC-hh cryogenic requirements and presents the main results of Air Liquide study confirming the novel precooling refrigeration option down to 40 K.
id oai-inspirehep.net-1808216
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
publisher IOP
record_format invenio
spelling oai-inspirehep.net-18082162020-12-14T13:46:14Zdoi:10.1088/1757-899X/755/1/012085http://cds.cern.ch/record/2725610engTavian, LMillet, FRoig, MZick, GBernhardt, JMPreliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide StudyAccelerators and Storage RingsDetectors and Experimental TechniquesIn the framework of a world-wide international collaboration, the FCC-hh, a 100 TeV hadron collider in a 100-km long tunnel, is proposed as a future circular collider beyond LHC at CERN offering the broadest discovery potential at the energy frontier. For such high performance hadron collider, the cryogenic system has to distribute very large cooling capacities all along the 100-km tunnel for the superconducting magnets continuously cooled at 1.9 K and for the beam screens operated between 40 and 60 K. The required total cooling power will be produced in 10 refrigeration plants with a unit equivalent capacity of 100 kW at 4.5 K, up to 4 times larger than the present state-of-the-art. Half of the entropic refrigeration load is due to the synchrotron radiation produced by the high-energy proton beams and deposited on beam screens actively cooled around 50 K. This non-conventional thermal load distribution is an additional challenge for the FCC-hh cryogenic system. Furthermore, the cryogenic system has to cool down the cold mass of the FCC-hh machine in less than 20 days with controlled thermal gradients in the cryo-magnets and beam screens. Based on preliminary design works from research institutes, an engineering study was performed with world-leader industries to assess a preliminary conceptual design for the FCC-hh cryogenic plants with industrial solutions and innovative technologies. The present paper recalls the FCC-hh cryogenic requirements and presents the main results of Air Liquide study confirming the novel precooling refrigeration option down to 40 K.IOPoai:inspirehep.net:18082162020
spellingShingle Accelerators and Storage Rings
Detectors and Experimental Techniques
Tavian, L
Millet, F
Roig, M
Zick, G
Bernhardt, JM
Preliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide Study
title Preliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide Study
title_full Preliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide Study
title_fullStr Preliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide Study
title_full_unstemmed Preliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide Study
title_short Preliminary conceptual design of FCC-hh cryo-refrigerators: Air Liquide Study
title_sort preliminary conceptual design of fcc-hh cryo-refrigerators: air liquide study
topic Accelerators and Storage Rings
Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1757-899X/755/1/012085
http://cds.cern.ch/record/2725610
work_keys_str_mv AT tavianl preliminaryconceptualdesignoffcchhcryorefrigeratorsairliquidestudy
AT milletf preliminaryconceptualdesignoffcchhcryorefrigeratorsairliquidestudy
AT roigm preliminaryconceptualdesignoffcchhcryorefrigeratorsairliquidestudy
AT zickg preliminaryconceptualdesignoffcchhcryorefrigeratorsairliquidestudy
AT bernhardtjm preliminaryconceptualdesignoffcchhcryorefrigeratorsairliquidestudy