Cargando…

Thermal neutron measurements by Timepix detector in H4IRRAD at CERN

Timepix, a pixel detector, was installed in the H4IRRAD irradiation area at CERN to study its response to a mixed radiation field. The measured data were compared to Monte Carlo simulations performed by the FLUKA code. This paper focuses on thermal neutron fluence measurement and simulation studies....

Descripción completa

Detalles Bibliográficos
Autores principales: Biskup, B, Brugger, M, Calviani, M, Efthymiopoulos, I, Pospisil, S, Solc, J, Stekl, I, Vykydal, Z
Lenguaje:eng
Publicado: 2019
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2019.162530
http://cds.cern.ch/record/2729622
_version_ 1780966459609972736
author Biskup, B
Brugger, M
Calviani, M
Efthymiopoulos, I
Pospisil, S
Solc, J
Stekl, I
Vykydal, Z
author_facet Biskup, B
Brugger, M
Calviani, M
Efthymiopoulos, I
Pospisil, S
Solc, J
Stekl, I
Vykydal, Z
author_sort Biskup, B
collection CERN
description Timepix, a pixel detector, was installed in the H4IRRAD irradiation area at CERN to study its response to a mixed radiation field. The measured data were compared to Monte Carlo simulations performed by the FLUKA code. This paper focuses on thermal neutron fluence measurement and simulation studies. The observed disagreement between the measured and simulated thermal neutron fluence of a factor 2.6 is discussed and the influence of the shielding material composition on this disagreement is studied.
id oai-inspirehep.net-1812934
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-18129342020-09-03T21:25:38Zdoi:10.1016/j.nima.2019.162530http://cds.cern.ch/record/2729622engBiskup, BBrugger, MCalviani, MEfthymiopoulos, IPospisil, SSolc, JStekl, IVykydal, ZThermal neutron measurements by Timepix detector in H4IRRAD at CERNTimepix, a pixel detector, was installed in the H4IRRAD irradiation area at CERN to study its response to a mixed radiation field. The measured data were compared to Monte Carlo simulations performed by the FLUKA code. This paper focuses on thermal neutron fluence measurement and simulation studies. The observed disagreement between the measured and simulated thermal neutron fluence of a factor 2.6 is discussed and the influence of the shielding material composition on this disagreement is studied.oai:inspirehep.net:18129342019
spellingShingle Biskup, B
Brugger, M
Calviani, M
Efthymiopoulos, I
Pospisil, S
Solc, J
Stekl, I
Vykydal, Z
Thermal neutron measurements by Timepix detector in H4IRRAD at CERN
title Thermal neutron measurements by Timepix detector in H4IRRAD at CERN
title_full Thermal neutron measurements by Timepix detector in H4IRRAD at CERN
title_fullStr Thermal neutron measurements by Timepix detector in H4IRRAD at CERN
title_full_unstemmed Thermal neutron measurements by Timepix detector in H4IRRAD at CERN
title_short Thermal neutron measurements by Timepix detector in H4IRRAD at CERN
title_sort thermal neutron measurements by timepix detector in h4irrad at cern
url https://dx.doi.org/10.1016/j.nima.2019.162530
http://cds.cern.ch/record/2729622
work_keys_str_mv AT biskupb thermalneutronmeasurementsbytimepixdetectorinh4irradatcern
AT bruggerm thermalneutronmeasurementsbytimepixdetectorinh4irradatcern
AT calvianim thermalneutronmeasurementsbytimepixdetectorinh4irradatcern
AT efthymiopoulosi thermalneutronmeasurementsbytimepixdetectorinh4irradatcern
AT pospisils thermalneutronmeasurementsbytimepixdetectorinh4irradatcern
AT solcj thermalneutronmeasurementsbytimepixdetectorinh4irradatcern
AT stekli thermalneutronmeasurementsbytimepixdetectorinh4irradatcern
AT vykydalz thermalneutronmeasurementsbytimepixdetectorinh4irradatcern