Cargando…

Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip

The RD53A is a prototype of the readout chip that will be used in the Compact Muon Solenoid (CMS) pixel detector after the High-Lumi LHC (HL-LHC) upgrade is complete beyond 2025. A new feature of the chip enables the writing of configuration commands between triggers during operation. This feature c...

Descripción completa

Detalles Bibliográficos
Autores principales: Backhaus, M, Garcia-Sciveres, M, Glessgen, F, Heim, T, Ristic, B, Wallny, R
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2020.164594
http://cds.cern.ch/record/2737318
_version_ 1780967741481549824
author Backhaus, M
Garcia-Sciveres, M
Glessgen, F
Heim, T
Ristic, B
Wallny, R
author_facet Backhaus, M
Garcia-Sciveres, M
Glessgen, F
Heim, T
Ristic, B
Wallny, R
author_sort Backhaus, M
collection CERN
description The RD53A is a prototype of the readout chip that will be used in the Compact Muon Solenoid (CMS) pixel detector after the High-Lumi LHC (HL-LHC) upgrade is complete beyond 2025. A new feature of the chip enables the writing of configuration commands between triggers during operation. This feature can be used to compensate for a detuning of the pixels due to radiation damage or temperature fluctuations over time. This paper studies the efficiency of such a method as well as its side-effects and the dependency on its parameters using an equivalent software implementation.
id oai-inspirehep.net-1818313
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling oai-inspirehep.net-18183132020-10-08T12:07:06Zdoi:10.1016/j.nima.2020.164594http://cds.cern.ch/record/2737318engBackhaus, MGarcia-Sciveres, MGlessgen, FHeim, TRistic, BWallny, RStudy and parameter optimization of a tuning method for the online calibration of the RD53A readout chipDetectors and Experimental TechniquesThe RD53A is a prototype of the readout chip that will be used in the Compact Muon Solenoid (CMS) pixel detector after the High-Lumi LHC (HL-LHC) upgrade is complete beyond 2025. A new feature of the chip enables the writing of configuration commands between triggers during operation. This feature can be used to compensate for a detuning of the pixels due to radiation damage or temperature fluctuations over time. This paper studies the efficiency of such a method as well as its side-effects and the dependency on its parameters using an equivalent software implementation.oai:inspirehep.net:18183132020
spellingShingle Detectors and Experimental Techniques
Backhaus, M
Garcia-Sciveres, M
Glessgen, F
Heim, T
Ristic, B
Wallny, R
Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip
title Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip
title_full Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip
title_fullStr Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip
title_full_unstemmed Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip
title_short Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip
title_sort study and parameter optimization of a tuning method for the online calibration of the rd53a readout chip
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2020.164594
http://cds.cern.ch/record/2737318
work_keys_str_mv AT backhausm studyandparameteroptimizationofatuningmethodfortheonlinecalibrationoftherd53areadoutchip
AT garciasciveresm studyandparameteroptimizationofatuningmethodfortheonlinecalibrationoftherd53areadoutchip
AT glessgenf studyandparameteroptimizationofatuningmethodfortheonlinecalibrationoftherd53areadoutchip
AT heimt studyandparameteroptimizationofatuningmethodfortheonlinecalibrationoftherd53areadoutchip
AT risticb studyandparameteroptimizationofatuningmethodfortheonlinecalibrationoftherd53areadoutchip
AT wallnyr studyandparameteroptimizationofatuningmethodfortheonlinecalibrationoftherd53areadoutchip