Cargando…

Measurement of the $\alpha$ ratio and $(n,\gamma)$ cross section of $^{235}\mathrm{U}$ from 0.2 to 200 eV at n_TOF

We measured the neutron capture-to-fission cross-section ratio (α ratio) and the capture cross section of U235 between 0.2 and 200 eV at the n_TOF facility at CERN. The simultaneous measurement of neutron-induced capture and fission rates was performed by means of the n_TOF BaF2 Total Absorption Cal...

Descripción completa

Detalles Bibliográficos
Autores principales: Balibrea-Correa, J, Mendoza, E, Cano-Ott, D, González, E, Capote, R, Krtička, M, Altstadt, S, Andrzejewski, J, Audouin, L, Bécares, V, Barbagallo, M, Bečvář, F, Belloni, F, Berthoumieux, E, Billowes, J, Boccone, V, Bosnar, D, Brugger, M, Calviani, M, Calviño, F, Carrapiço, C, Cerutti, F, Chiaveri, E, Chin, M, Colonna, N, Cortés, G, Cortés-Giraldo, M A, Diakaki, M, Domingo-Pardo, C, Dressler, R, Durán, I, Eleftheriadis, C, Ferrari, A, Fraval, K, Furman, V, Göbel, K, Gómez-Hornillos, M B, Ganesan, S, García, A R, Giubrone, G, Gonçalves, I F, Goverdovski, A, Griesmayer, E, Guerrero, C, Gunsing, F, Heftrich, T, Hernández-Prieto, A, Heyse, J, Jenkins, D G, Jericha, E, Käppeler, F, Kadi, Y, Karadimos, D, Katabuchi, T, Ketlerov, V, Khryachkov, V, Kivel, N, Koehler, P, Kokkoris, M, Kroll, J, Lampoudis, C, Langer, C, Leal-Cidoncha, E, Lederer, C, Leeb, H, Leong, L S, Lerendegui-Marco, J, Losito, R, Mallick, A, Manousos, A, Marganiec, J, Martínez, T, Massimi, C, Mastinu, P, Mastromarco, M, Mengoni, A, Milazzo, P M, Mingrone, F, Mirea, M, Mondelaers, W, Paradela, C, Pavlik, A, Perkowski, J, Plompen, A J M, Praena, J, Quesada, J M, Rauscher, T, Reifarth, R, Riego-Perez, A, Robles, M, Rubbia, C, Ryan, J A, Sabaté-Gilarte, M, Sarmento, R, Saxena, A, Schillebeeckx, P, Schmidt, S, Schumann, D, Sedyshev, P, Tagliente, G, Tain, J L, Tarifeño-Saldivia, A, Tarrío, D, Tassan-Got, L, Tsinganis, A, Valenta, S, Vannini, G, Variale, V, Vaz, P, Ventura, A, Vermeulen, M J, Vlachoudis, V, Vlastou, R, Wallner, A, Ware, T, Weigand, M, Weiss, C, Wright, T, Žugec, P
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1103/PhysRevC.102.044615
http://cds.cern.ch/record/2743940
Descripción
Sumario:We measured the neutron capture-to-fission cross-section ratio (α ratio) and the capture cross section of U235 between 0.2 and 200 eV at the n_TOF facility at CERN. The simultaneous measurement of neutron-induced capture and fission rates was performed by means of the n_TOF BaF2 Total Absorption Calorimeter (TAC), used for detection of γ rays, in combination with a set of micromegas detectors used as fission tagging detectors. The energy dependence of the capture cross section was obtained with help of the Li6(n,t) standard reaction determining the n_TOF neutron fluence; the well-known integral of the U235(n,f) cross section between 7.8 and 11 eV was then used for its absolute normalization. The α ratio, obtained with slightly higher statistical fluctuations, was determined directly, without need for any reference cross section. To perform the analysis of this measurement we developed a new methodology to correct the experimentally observed effect that the probabilities of detecting a fission reaction in the TAC and the micromegas detectors are not independent. The results of this work have been used in a new evaluation of U235 performed within the scope of the Collaborative International Evaluated Library Organisation (CIELO) Project, and are consistent with the ENDF/B-VIII.0 and JEFF-3.3 capture cross sections below 4 eV and above 100 eV. However, the measured capture cross section is on average 10% larger between 4 and 100 eV.