Cargando…

On-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber array

In this study, the possibility of on-line monitoring of an ultra-high-energy (UHE) beam of 150 GeV/n lead ($^{208}$Pb) ions using a liquid-filled ionization chamber array (OCTAVIUS 1000SRS, PTW Freiburg, Germany) is evaluated. The applicability of the array has been tested for the investigated beam,...

Descripción completa

Detalles Bibliográficos
Autores principales: Wyrwoll, V, Delfs, B, Lapp, M, Poppinga, D, Fernandéz Martinéz, P, Kastriotou, M, García Alía, R, Røed, K, Gerbershagen, A, Looe, H K, Poppe, B
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2020.164831
http://cds.cern.ch/record/2744545
_version_ 1780968706500722688
author Wyrwoll, V
Delfs, B
Lapp, M
Poppinga, D
Fernandéz Martinéz, P
Kastriotou, M
García Alía, R
Røed, K
Gerbershagen, A
Looe, H K
Poppe, B
author_facet Wyrwoll, V
Delfs, B
Lapp, M
Poppinga, D
Fernandéz Martinéz, P
Kastriotou, M
García Alía, R
Røed, K
Gerbershagen, A
Looe, H K
Poppe, B
author_sort Wyrwoll, V
collection CERN
description In this study, the possibility of on-line monitoring of an ultra-high-energy (UHE) beam of 150 GeV/n lead ($^{208}$Pb) ions using a liquid-filled ionization chamber array (OCTAVIUS 1000SRS, PTW Freiburg, Germany) is evaluated. The applicability of the array has been tested for the investigated beam, where adequate adjustments of the array have been made for measurements under very low fluxes of $10^2$ to $10^4$  ions / cm$^2$ /s. The results have been compared to measurements obtained using the standard beam line detectors, such as a scintillator and a delay wire chamber (DWC). Since these detectors were situated further upstream from the experimental position, measurements with these devices may not be representative of the beam characteristics at setup due to the interactions of the primary beam particles within these detectors and the subsequent transport of these particles between these detectors and the setup. The main advantage of the application of the liquid-filled array is its portability so that it can be placed directly at the position of the experimental setup to capture the beam characteristics. A comparison between the measured beam profile and independent film measurements has demonstrated its reliability for analysing the beam characteristics. In this context, the 2D array has been implemented to measure on-line not only the 2D beam profile but also the total imparting particle fluence of the UHE lead beam by using the measured dose and considering the calibration of the detector.
id oai-inspirehep.net-1829374
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling oai-inspirehep.net-18293742022-08-10T12:00:27Zdoi:10.1016/j.nima.2020.164831http://cds.cern.ch/record/2744545engWyrwoll, VDelfs, BLapp, MPoppinga, DFernandéz Martinéz, PKastriotou, MGarcía Alía, RRøed, KGerbershagen, ALooe, H KPoppe, BOn-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber arrayAccelerators and Storage RingsDetectors and Experimental TechniquesIn this study, the possibility of on-line monitoring of an ultra-high-energy (UHE) beam of 150 GeV/n lead ($^{208}$Pb) ions using a liquid-filled ionization chamber array (OCTAVIUS 1000SRS, PTW Freiburg, Germany) is evaluated. The applicability of the array has been tested for the investigated beam, where adequate adjustments of the array have been made for measurements under very low fluxes of $10^2$ to $10^4$  ions / cm$^2$ /s. The results have been compared to measurements obtained using the standard beam line detectors, such as a scintillator and a delay wire chamber (DWC). Since these detectors were situated further upstream from the experimental position, measurements with these devices may not be representative of the beam characteristics at setup due to the interactions of the primary beam particles within these detectors and the subsequent transport of these particles between these detectors and the setup. The main advantage of the application of the liquid-filled array is its portability so that it can be placed directly at the position of the experimental setup to capture the beam characteristics. A comparison between the measured beam profile and independent film measurements has demonstrated its reliability for analysing the beam characteristics. In this context, the 2D array has been implemented to measure on-line not only the 2D beam profile but also the total imparting particle fluence of the UHE lead beam by using the measured dose and considering the calibration of the detector.oai:inspirehep.net:18293742021
spellingShingle Accelerators and Storage Rings
Detectors and Experimental Techniques
Wyrwoll, V
Delfs, B
Lapp, M
Poppinga, D
Fernandéz Martinéz, P
Kastriotou, M
García Alía, R
Røed, K
Gerbershagen, A
Looe, H K
Poppe, B
On-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber array
title On-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber array
title_full On-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber array
title_fullStr On-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber array
title_full_unstemmed On-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber array
title_short On-line beam monitoring and dose profile measurements of a $^{208}$Pb beam of 150 GeV/n with a liquid-filled ionization chamber array
title_sort on-line beam monitoring and dose profile measurements of a $^{208}$pb beam of 150 gev/n with a liquid-filled ionization chamber array
topic Accelerators and Storage Rings
Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2020.164831
http://cds.cern.ch/record/2744545
work_keys_str_mv AT wyrwollv onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT delfsb onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT lappm onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT poppingad onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT fernandezmartinezp onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT kastriotoum onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT garciaaliar onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT røedk onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT gerbershagena onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT looehk onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray
AT poppeb onlinebeammonitoringanddoseprofilemeasurementsofa208pbbeamof150gevnwithaliquidfilledionizationchamberarray