Cargando…

Investigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors

The CMS and ATLAS detectors will face challenging conditions after the upgrade of the LHC to the High Luminosity LHC. In particular, the granularity of the pixel detectors should increase to mitigate the effect of pileup. Two possible sensor geometries are being investigated, $50\times50\ \mu m^2$ a...

Descripción completa

Detalles Bibliográficos
Autores principales: Jofrehei, Arash, Canelli, Florencia, Kilminster, Ben, Leontsinis, Stefanos, Macchiolo, Anna, Mikuni, Vinicius Massami, Meng, Lingxin
Lenguaje:eng
Publicado: SISSA 2020
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.364.0151
http://cds.cern.ch/record/2766075
_version_ 1780971298759901184
author Jofrehei, Arash
Canelli, Florencia
Kilminster, Ben
Leontsinis, Stefanos
Macchiolo, Anna
Mikuni, Vinicius Massami
Meng, Lingxin
author_facet Jofrehei, Arash
Canelli, Florencia
Kilminster, Ben
Leontsinis, Stefanos
Macchiolo, Anna
Mikuni, Vinicius Massami
Meng, Lingxin
author_sort Jofrehei, Arash
collection CERN
description The CMS and ATLAS detectors will face challenging conditions after the upgrade of the LHC to the High Luminosity LHC. In particular, the granularity of the pixel detectors should increase to mitigate the effect of pileup. Two possible sensor geometries are being investigated, $50\times50\ \mu m^2$ and $25\times100\ \mu m^2$, to handle these conditions. One of the main factors in choosing the pixel geometry is inter-channel charge induction or crosstalk, defined as the ratio of charge induced into neighboring pixels relative to the total charge. This charge induction will affect the data rates, position resolution, and track reconstruction efficiencies. Therefore, it should be investigated carefully. The effect of crosstalk is expected to depend on the chosen pixel geometry, threshold of the signal, and readout front-end. The readout chip in this study is RD53A, developed by the RD53 Collaboration, which is a prototype investigated by both the CMS and ATLAS collaborations implementing three different analog front-end designs. Crosstalk effects are larger for the $25\times100\ \mu m^2$ geometry, given the larger sensor capacitance. Both have been studied in the lab through direct charge injection, and also at DESY test beam facility by charge deposition of 5.6 GeV electrons in 150 $\mu m$ thick silicon pixels. The effects on the cross-talk due to varying the front-end, threshold, and the impinging position of the electrons will be presented.
id oai-inspirehep.net-1830804
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
publisher SISSA
record_format invenio
spelling oai-inspirehep.net-18308042022-01-14T14:55:10Zdoi:10.22323/1.364.0151http://cds.cern.ch/record/2766075engJofrehei, ArashCanelli, FlorenciaKilminster, BenLeontsinis, StefanosMacchiolo, AnnaMikuni, Vinicius MassamiMeng, LingxinInvestigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensorsDetectors and Experimental TechniquesThe CMS and ATLAS detectors will face challenging conditions after the upgrade of the LHC to the High Luminosity LHC. In particular, the granularity of the pixel detectors should increase to mitigate the effect of pileup. Two possible sensor geometries are being investigated, $50\times50\ \mu m^2$ and $25\times100\ \mu m^2$, to handle these conditions. One of the main factors in choosing the pixel geometry is inter-channel charge induction or crosstalk, defined as the ratio of charge induced into neighboring pixels relative to the total charge. This charge induction will affect the data rates, position resolution, and track reconstruction efficiencies. Therefore, it should be investigated carefully. The effect of crosstalk is expected to depend on the chosen pixel geometry, threshold of the signal, and readout front-end. The readout chip in this study is RD53A, developed by the RD53 Collaboration, which is a prototype investigated by both the CMS and ATLAS collaborations implementing three different analog front-end designs. Crosstalk effects are larger for the $25\times100\ \mu m^2$ geometry, given the larger sensor capacitance. Both have been studied in the lab through direct charge injection, and also at DESY test beam facility by charge deposition of 5.6 GeV electrons in 150 $\mu m$ thick silicon pixels. The effects on the cross-talk due to varying the front-end, threshold, and the impinging position of the electrons will be presented.SISSAoai:inspirehep.net:18308042020
spellingShingle Detectors and Experimental Techniques
Jofrehei, Arash
Canelli, Florencia
Kilminster, Ben
Leontsinis, Stefanos
Macchiolo, Anna
Mikuni, Vinicius Massami
Meng, Lingxin
Investigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors
title Investigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors
title_full Investigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors
title_fullStr Investigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors
title_full_unstemmed Investigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors
title_short Investigation of crosstalk effects in RD53A modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors
title_sort investigation of crosstalk effects in rd53a modules with 100 and 150 $\mathrm{\mu m}$ thick n-in-p planar sensors
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.22323/1.364.0151
http://cds.cern.ch/record/2766075
work_keys_str_mv AT jofreheiarash investigationofcrosstalkeffectsinrd53amoduleswith100and150mathrmmumthickninpplanarsensors
AT canelliflorencia investigationofcrosstalkeffectsinrd53amoduleswith100and150mathrmmumthickninpplanarsensors
AT kilminsterben investigationofcrosstalkeffectsinrd53amoduleswith100and150mathrmmumthickninpplanarsensors
AT leontsinisstefanos investigationofcrosstalkeffectsinrd53amoduleswith100and150mathrmmumthickninpplanarsensors
AT macchioloanna investigationofcrosstalkeffectsinrd53amoduleswith100and150mathrmmumthickninpplanarsensors
AT mikuniviniciusmassami investigationofcrosstalkeffectsinrd53amoduleswith100and150mathrmmumthickninpplanarsensors
AT menglingxin investigationofcrosstalkeffectsinrd53amoduleswith100and150mathrmmumthickninpplanarsensors