Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms

The establishment of an in vivo internal monitoring programme requires the use of phantoms to represent an activity distribution of an incorporated radionuclide within the body. The aim of this study was to quantify the impact of the phantom geometry on the minimum detectable activity (MDA) of an in...

Descripción completa

Detalles Bibliográficos
Autores principales: Medici, Siria, Desorgher, Laurent, Carbonez, Pierre, Damet, Jérôme, Bochud, François, Pitzschke, Andreas
Lenguaje:eng
Publicado: 2020
Acceso en línea:https://dx.doi.org/10.1016/j.radmeas.2020.106485
http://cds.cern.ch/record/2745529
_version_ 1780968813672529920
author Medici, Siria
Desorgher, Laurent
Carbonez, Pierre
Damet, Jérôme
Bochud, François
Pitzschke, Andreas
author_facet Medici, Siria
Desorgher, Laurent
Carbonez, Pierre
Damet, Jérôme
Bochud, François
Pitzschke, Andreas
author_sort Medici, Siria
collection CERN
description The establishment of an in vivo internal monitoring programme requires the use of phantoms to represent an activity distribution of an incorporated radionuclide within the body. The aim of this study was to quantify the impact of the phantom geometry on the minimum detectable activity (MDA) of an incorporated radionuclide. The MDA was assessed for two instruments: a conventional radiation protection instrument and a portable gamma spectrometer. Four phantoms were considered: two physical phantoms, a simplified torso phantom and a commercial whole body phantom, as well as two numerical phantoms, the reference adult male and female voxel phantoms published by the International Commission on Radiological Protection (ICRP). The phantoms were loaded with activity at the level of the thorax and abdomen using reference sources of $^{57}$Co, $^{133}$Ba, $^{137}$Cs, $^{60}$Co and $^{152}$Eu. The MDA for both instruments was experimentally assessed using the two physical phantoms. The experimental setup was modelled in GEANT4 and the simulated instrument responses were validated by the experimental data. The Monte Carlo model was then used to compute the instruments response and corresponding MDA when using the ICRP voxel phantoms. The simplified torso phantom provided one of the highest MDA estimates, up to a factor of 5 higher than the ones obtained with the voxel phantoms when considering a $^{57}$Co source. Depending on the considered source distribution within the phantoms, physical phantoms may lead to an underestimation of the MDA when compared to more complex and anatomically accurate numerical phantoms. This work presents a quantitative comparison between the MDA obtained with different phantoms and radionuclide distributions.
id oai-inspirehep.net-1831571
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling oai-inspirehep.net-18315712020-11-21T20:36:59Zdoi:10.1016/j.radmeas.2020.106485http://cds.cern.ch/record/2745529engMedici, SiriaDesorgher, LaurentCarbonez, PierreDamet, JérômeBochud, FrançoisPitzschke, AndreasImpact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantomsThe establishment of an in vivo internal monitoring programme requires the use of phantoms to represent an activity distribution of an incorporated radionuclide within the body. The aim of this study was to quantify the impact of the phantom geometry on the minimum detectable activity (MDA) of an incorporated radionuclide. The MDA was assessed for two instruments: a conventional radiation protection instrument and a portable gamma spectrometer. Four phantoms were considered: two physical phantoms, a simplified torso phantom and a commercial whole body phantom, as well as two numerical phantoms, the reference adult male and female voxel phantoms published by the International Commission on Radiological Protection (ICRP). The phantoms were loaded with activity at the level of the thorax and abdomen using reference sources of $^{57}$Co, $^{133}$Ba, $^{137}$Cs, $^{60}$Co and $^{152}$Eu. The MDA for both instruments was experimentally assessed using the two physical phantoms. The experimental setup was modelled in GEANT4 and the simulated instrument responses were validated by the experimental data. The Monte Carlo model was then used to compute the instruments response and corresponding MDA when using the ICRP voxel phantoms. The simplified torso phantom provided one of the highest MDA estimates, up to a factor of 5 higher than the ones obtained with the voxel phantoms when considering a $^{57}$Co source. Depending on the considered source distribution within the phantoms, physical phantoms may lead to an underestimation of the MDA when compared to more complex and anatomically accurate numerical phantoms. This work presents a quantitative comparison between the MDA obtained with different phantoms and radionuclide distributions.oai:inspirehep.net:18315712020
spellingShingle Medici, Siria
Desorgher, Laurent
Carbonez, Pierre
Damet, Jérôme
Bochud, François
Pitzschke, Andreas
Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms
title Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms
title_full Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms
title_fullStr Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms
title_full_unstemmed Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms
title_short Impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: From physical to numerical phantoms
title_sort impact of the phantom geometry on the evaluation of the minimum detectable activity following a radionuclide intake: from physical to numerical phantoms
url https://dx.doi.org/10.1016/j.radmeas.2020.106485
http://cds.cern.ch/record/2745529
work_keys_str_mv AT medicisiria impactofthephantomgeometryontheevaluationoftheminimumdetectableactivityfollowingaradionuclideintakefromphysicaltonumericalphantoms
AT desorgherlaurent impactofthephantomgeometryontheevaluationoftheminimumdetectableactivityfollowingaradionuclideintakefromphysicaltonumericalphantoms
AT carbonezpierre impactofthephantomgeometryontheevaluationoftheminimumdetectableactivityfollowingaradionuclideintakefromphysicaltonumericalphantoms
AT dametjerome impactofthephantomgeometryontheevaluationoftheminimumdetectableactivityfollowingaradionuclideintakefromphysicaltonumericalphantoms
AT bochudfrancois impactofthephantomgeometryontheevaluationoftheminimumdetectableactivityfollowingaradionuclideintakefromphysicaltonumericalphantoms
AT pitzschkeandreas impactofthephantomgeometryontheevaluationoftheminimumdetectableactivityfollowingaradionuclideintakefromphysicaltonumericalphantoms