Cargando…

Efficient Iterative Calibration on the Grid using iLCDirac

Software tools for detector optimization studies for future experiments need to be efficient and reliable. One important ingredient of the detector design optimization concerns the calorimeter system. Every change of the calorimeter configuration requires a new set of overall calibration parameters...

Descripción completa

Detalles Bibliográficos
Autores principales: Viazlo, Oleksandr, Sailer, André
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1051/epjconf/202024503003
http://cds.cern.ch/record/2753975
_version_ 1780969439816056832
author Viazlo, Oleksandr
Sailer, André
author_facet Viazlo, Oleksandr
Sailer, André
author_sort Viazlo, Oleksandr
collection CERN
description Software tools for detector optimization studies for future experiments need to be efficient and reliable. One important ingredient of the detector design optimization concerns the calorimeter system. Every change of the calorimeter configuration requires a new set of overall calibration parameters which in turn requires a new calorimeter calibration to be done. An efficient way to perform calorimeter calibration is therefore essential in any detector optimization tool set. In this contribution, we present the implementation of a calibration system in iLCDirac, which is an extension of the DIRAC grid interware. Our approach provides more direct control over the grid resources to reduce overhead of file download and job initialisation, and provides more flexibility during the calibration process. The service controls the whole chain of a calibration procedure, collects results from finished iterations and redistributes new input parameters among worker nodes. A dedicated agent monitors the health of running jobs and resubmits them if needed. Each calibration has an up-to-date backup which can be used for recovery in case of any disruption in the operation of the service. As a use case, we will present a study of optimization of the calorimetry system of the CLD detector concept for FCC-ee, which has been adopted from the CLICdet detector model. The detector has been simulated with the DD4hep package and calorimetry performance has been studied with the particle flow package PandoraPFA.
id oai-inspirehep.net-1832076
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling oai-inspirehep.net-18320762021-03-15T21:27:27Zdoi:10.1051/epjconf/202024503003http://cds.cern.ch/record/2753975engViazlo, OleksandrSailer, AndréEfficient Iterative Calibration on the Grid using iLCDiracComputing and ComputersSoftware tools for detector optimization studies for future experiments need to be efficient and reliable. One important ingredient of the detector design optimization concerns the calorimeter system. Every change of the calorimeter configuration requires a new set of overall calibration parameters which in turn requires a new calorimeter calibration to be done. An efficient way to perform calorimeter calibration is therefore essential in any detector optimization tool set. In this contribution, we present the implementation of a calibration system in iLCDirac, which is an extension of the DIRAC grid interware. Our approach provides more direct control over the grid resources to reduce overhead of file download and job initialisation, and provides more flexibility during the calibration process. The service controls the whole chain of a calibration procedure, collects results from finished iterations and redistributes new input parameters among worker nodes. A dedicated agent monitors the health of running jobs and resubmits them if needed. Each calibration has an up-to-date backup which can be used for recovery in case of any disruption in the operation of the service. As a use case, we will present a study of optimization of the calorimetry system of the CLD detector concept for FCC-ee, which has been adopted from the CLICdet detector model. The detector has been simulated with the DD4hep package and calorimetry performance has been studied with the particle flow package PandoraPFA.oai:inspirehep.net:18320762020
spellingShingle Computing and Computers
Viazlo, Oleksandr
Sailer, André
Efficient Iterative Calibration on the Grid using iLCDirac
title Efficient Iterative Calibration on the Grid using iLCDirac
title_full Efficient Iterative Calibration on the Grid using iLCDirac
title_fullStr Efficient Iterative Calibration on the Grid using iLCDirac
title_full_unstemmed Efficient Iterative Calibration on the Grid using iLCDirac
title_short Efficient Iterative Calibration on the Grid using iLCDirac
title_sort efficient iterative calibration on the grid using ilcdirac
topic Computing and Computers
url https://dx.doi.org/10.1051/epjconf/202024503003
http://cds.cern.ch/record/2753975
work_keys_str_mv AT viazlooleksandr efficientiterativecalibrationonthegridusingilcdirac
AT sailerandre efficientiterativecalibrationonthegridusingilcdirac