Cargando…

Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage

This paper presents the first plasmid DNA irradiations carried out with Very High Energy Electrons (VHEE) over 100–200 MeV at the CLEAR user facility at CERN to determine the Relative Biological Effectiveness (RBE) of VHEE. DNA damage yields were measured in dry and aqueous environments to determine...

Descripción completa

Detalles Bibliográficos
Autores principales: Small, K L, Henthorn, N T, Angal-Kalinin, D, Chadwick, A L, Santina, E, Aitkenhead, A, Kirkby, K J, Smith, R J, Surman, M, Jones, J, Farabolini, W, Corsini, R, Gamba, D, Gilardi, A, Merchant, M J, Jones, R M
Lenguaje:eng
Publicado: 2021
Acceso en línea:https://dx.doi.org/10.1038/s41598-021-82772-6
http://cds.cern.ch/record/2752325
_version_ 1780969344125108224
author Small, K L
Henthorn, N T
Angal-Kalinin, D
Chadwick, A L
Santina, E
Aitkenhead, A
Kirkby, K J
Smith, R J
Surman, M
Jones, J
Farabolini, W
Corsini, R
Gamba, D
Gilardi, A
Merchant, M J
Jones, R M
author_facet Small, K L
Henthorn, N T
Angal-Kalinin, D
Chadwick, A L
Santina, E
Aitkenhead, A
Kirkby, K J
Smith, R J
Surman, M
Jones, J
Farabolini, W
Corsini, R
Gamba, D
Gilardi, A
Merchant, M J
Jones, R M
author_sort Small, K L
collection CERN
description This paper presents the first plasmid DNA irradiations carried out with Very High Energy Electrons (VHEE) over 100–200 MeV at the CLEAR user facility at CERN to determine the Relative Biological Effectiveness (RBE) of VHEE. DNA damage yields were measured in dry and aqueous environments to determine that ~ 99% of total DNA breaks were caused by indirect effects, consistent with other published measurements for protons and photons. Double-Strand Break (DSB) yield was used as the biological endpoint for RBE calculation, with values found to be consistent with established radiotherapy modalities. Similarities in physical damage between VHEE and conventional modalities gives confidence that biological effects of VHEE will also be similar—key for clinical implementation. Damage yields were used as a baseline for track structure simulations of VHEE plasmid irradiation using GEANT4-DNA. Current models for DSB yield have shown reasonable agreement with experimental values. The growing interest in FLASH radiotherapy motivated a study into DSB yield variation with dose rate following VHEE irradiation. No significant variations were observed between conventional and FLASH dose rate irradiations, indicating that no FLASH effect is seen under these conditions.
id oai-inspirehep.net-1845696
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling oai-inspirehep.net-18456962021-02-19T13:52:57Zdoi:10.1038/s41598-021-82772-6http://cds.cern.ch/record/2752325engSmall, K LHenthorn, N TAngal-Kalinin, DChadwick, A LSantina, EAitkenhead, AKirkby, K JSmith, R JSurman, MJones, JFarabolini, WCorsini, RGamba, DGilardi, AMerchant, M JJones, R MEvaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damageThis paper presents the first plasmid DNA irradiations carried out with Very High Energy Electrons (VHEE) over 100–200 MeV at the CLEAR user facility at CERN to determine the Relative Biological Effectiveness (RBE) of VHEE. DNA damage yields were measured in dry and aqueous environments to determine that ~ 99% of total DNA breaks were caused by indirect effects, consistent with other published measurements for protons and photons. Double-Strand Break (DSB) yield was used as the biological endpoint for RBE calculation, with values found to be consistent with established radiotherapy modalities. Similarities in physical damage between VHEE and conventional modalities gives confidence that biological effects of VHEE will also be similar—key for clinical implementation. Damage yields were used as a baseline for track structure simulations of VHEE plasmid irradiation using GEANT4-DNA. Current models for DSB yield have shown reasonable agreement with experimental values. The growing interest in FLASH radiotherapy motivated a study into DSB yield variation with dose rate following VHEE irradiation. No significant variations were observed between conventional and FLASH dose rate irradiations, indicating that no FLASH effect is seen under these conditions.oai:inspirehep.net:18456962021
spellingShingle Small, K L
Henthorn, N T
Angal-Kalinin, D
Chadwick, A L
Santina, E
Aitkenhead, A
Kirkby, K J
Smith, R J
Surman, M
Jones, J
Farabolini, W
Corsini, R
Gamba, D
Gilardi, A
Merchant, M J
Jones, R M
Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage
title Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage
title_full Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage
title_fullStr Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage
title_full_unstemmed Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage
title_short Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage
title_sort evaluating very high energy electron rbe from nanodosimetric pbr322 plasmid dna damage
url https://dx.doi.org/10.1038/s41598-021-82772-6
http://cds.cern.ch/record/2752325
work_keys_str_mv AT smallkl evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT henthornnt evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT angalkalinind evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT chadwickal evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT santinae evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT aitkenheada evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT kirkbykj evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT smithrj evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT surmanm evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT jonesj evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT faraboliniw evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT corsinir evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT gambad evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT gilardia evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT merchantmj evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage
AT jonesrm evaluatingveryhighenergyelectronrbefromnanodosimetricpbr322plasmiddnadamage