Cargando…

Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland

Epidemiological studies indicate that radiation damages to the eye lens occurs at lower dose values than previously considered (Worgul et al., 2007; Chodick et al., 2008; Ciraj-Bjelac et al., 2010; Rehani et al., 2011; Vano et al., 2010) [1], [2], [3], [4], [5]. The International Commission on Radio...

Descripción completa

Detalles Bibliográficos
Autores principales: Sans-Merce, Marta, Lemesre, Camille, Elmiger, Raphael, Damet, Jérôme
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.ejmp.2018.12.001
http://cds.cern.ch/record/2759034
_version_ 1780970293637939200
author Sans-Merce, Marta
Lemesre, Camille
Elmiger, Raphael
Damet, Jérôme
author_facet Sans-Merce, Marta
Lemesre, Camille
Elmiger, Raphael
Damet, Jérôme
author_sort Sans-Merce, Marta
collection CERN
description Epidemiological studies indicate that radiation damages to the eye lens occurs at lower dose values than previously considered (Worgul et al., 2007; Chodick et al., 2008; Ciraj-Bjelac et al., 2010; Rehani et al., 2011; Vano et al., 2010) [1], [2], [3], [4], [5]. The International Commission on Radiological Protection lowered the equivalent dose limit value for the eye lens to 20 mSv/year (ICRP, n.d.) [6]. This new limit has been incorporated into the revised Swiss legislation [7]. Prior this change, it was agreed that if the effective dose limit was respected it would implicitly imply the respect of the limit to the eye lens, for penetrating radiation. The concept had to be reviewed in the light of necessary application of the new eye lens dose limit. The new Swiss legislation proposes to use the value of Hp(0.07) measured over the protective apron to estimate the eye lens dose. This study aims to investigate the validity of this approach for medical staff during fluoroscopy guided procedures. The results show that the ratio between thorax and eye lens doses varies greatly from one medical speciality to another, but also between surgeons within the same speciality. Moreover, for a given physician, the ratio varied over the periods of surveillance. Those variations confirmed the crucial influence of external parameters related to experience, practice and workload. The surveillance method is appropriate for most of the procedures performed in the department included in this study. Nevertheless, for the particular configuration in urology, the respect of the effective dose limit measured by the routine dosimetry does not allow direct compliance with the dose limit to the eye lens, unless appropriate protective eye wear gear are worn.
id oai-inspirehep.net-1849840
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-18498402021-06-21T13:14:21Zdoi:10.1016/j.ejmp.2018.12.001http://cds.cern.ch/record/2759034engSans-Merce, MartaLemesre, CamilleElmiger, RaphaelDamet, JérômeEye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in SwitzerlandHealth Physics and Radiation EffectsEpidemiological studies indicate that radiation damages to the eye lens occurs at lower dose values than previously considered (Worgul et al., 2007; Chodick et al., 2008; Ciraj-Bjelac et al., 2010; Rehani et al., 2011; Vano et al., 2010) [1], [2], [3], [4], [5]. The International Commission on Radiological Protection lowered the equivalent dose limit value for the eye lens to 20 mSv/year (ICRP, n.d.) [6]. This new limit has been incorporated into the revised Swiss legislation [7]. Prior this change, it was agreed that if the effective dose limit was respected it would implicitly imply the respect of the limit to the eye lens, for penetrating radiation. The concept had to be reviewed in the light of necessary application of the new eye lens dose limit. The new Swiss legislation proposes to use the value of Hp(0.07) measured over the protective apron to estimate the eye lens dose. This study aims to investigate the validity of this approach for medical staff during fluoroscopy guided procedures. The results show that the ratio between thorax and eye lens doses varies greatly from one medical speciality to another, but also between surgeons within the same speciality. Moreover, for a given physician, the ratio varied over the periods of surveillance. Those variations confirmed the crucial influence of external parameters related to experience, practice and workload. The surveillance method is appropriate for most of the procedures performed in the department included in this study. Nevertheless, for the particular configuration in urology, the respect of the effective dose limit measured by the routine dosimetry does not allow direct compliance with the dose limit to the eye lens, unless appropriate protective eye wear gear are worn.oai:inspirehep.net:18498402019
spellingShingle Health Physics and Radiation Effects
Sans-Merce, Marta
Lemesre, Camille
Elmiger, Raphael
Damet, Jérôme
Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland
title Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland
title_full Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland
title_fullStr Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland
title_full_unstemmed Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland
title_short Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland
title_sort eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in switzerland
topic Health Physics and Radiation Effects
url https://dx.doi.org/10.1016/j.ejmp.2018.12.001
http://cds.cern.ch/record/2759034
work_keys_str_mv AT sansmercemarta eyelensmonitoringprogrammeformedicalstaffinvolvedinfluoroscopyguidedinterventionalproceduresinswitzerland
AT lemesrecamille eyelensmonitoringprogrammeformedicalstaffinvolvedinfluoroscopyguidedinterventionalproceduresinswitzerland
AT elmigerraphael eyelensmonitoringprogrammeformedicalstaffinvolvedinfluoroscopyguidedinterventionalproceduresinswitzerland
AT dametjerome eyelensmonitoringprogrammeformedicalstaffinvolvedinfluoroscopyguidedinterventionalproceduresinswitzerland