Cargando…

Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera

The X-ray Integral Field Unit (X-IFU) is a cryogenic X-ray camera intended for the ATHENA space observatory. Its focal plane will contain a kilopixel array of Transition Edge Sensors (TESs), originally intended to be read out by a Frequency Domain Multiplexer involving 40 carrier frequencies in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kiviranta, Mikko, Grönberg, Leif, Puranen, Tuomas, van der Kuur, Jan, Beev, Nikolai, Salonen, Jaakko, Hazra, Dibyendu, Korpela, Seppo
Lenguaje:eng
Publicado: 2021
Acceso en línea:https://dx.doi.org/10.1109/TASC.2021.3060356
http://cds.cern.ch/record/2765832
_version_ 1780971187202949120
author Kiviranta, Mikko
Grönberg, Leif
Puranen, Tuomas
van der Kuur, Jan
Beev, Nikolai
Salonen, Jaakko
Hazra, Dibyendu
Korpela, Seppo
author_facet Kiviranta, Mikko
Grönberg, Leif
Puranen, Tuomas
van der Kuur, Jan
Beev, Nikolai
Salonen, Jaakko
Hazra, Dibyendu
Korpela, Seppo
author_sort Kiviranta, Mikko
collection CERN
description The X-ray Integral Field Unit (X-IFU) is a cryogenic X-ray camera intended for the ATHENA space observatory. Its focal plane will contain a kilopixel array of Transition Edge Sensors (TESs), originally intended to be read out by a Frequency Domain Multiplexer involving 40 carrier frequencies in the 1-5 MHz range per readout channel. We review dimensioning principles and fabrication of a SQUID tandem, operating at 50 mK and 2 K temperatures, intended to amplify the multiplexed signal from the TES array. The first measurements indicate a 40 ħ coupled energy resolution in the relevant frequency band, and sufficient linearity to reach the required 1% total harmonic distortion. Additionally, we describe the non-multiplexed amplifier SQUID for the X-IFU anti-coincidence detector.
id oai-inspirehep.net-1860940
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling oai-inspirehep.net-18609402021-05-07T11:28:38Zdoi:10.1109/TASC.2021.3060356http://cds.cern.ch/record/2765832engKiviranta, MikkoGrönberg, LeifPuranen, Tuomasvan der Kuur, JanBeev, NikolaiSalonen, JaakkoHazra, DibyenduKorpela, SeppoTwo-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray CameraThe X-ray Integral Field Unit (X-IFU) is a cryogenic X-ray camera intended for the ATHENA space observatory. Its focal plane will contain a kilopixel array of Transition Edge Sensors (TESs), originally intended to be read out by a Frequency Domain Multiplexer involving 40 carrier frequencies in the 1-5 MHz range per readout channel. We review dimensioning principles and fabrication of a SQUID tandem, operating at 50 mK and 2 K temperatures, intended to amplify the multiplexed signal from the TES array. The first measurements indicate a 40 ħ coupled energy resolution in the relevant frequency band, and sufficient linearity to reach the required 1% total harmonic distortion. Additionally, we describe the non-multiplexed amplifier SQUID for the X-IFU anti-coincidence detector.oai:inspirehep.net:18609402021
spellingShingle Kiviranta, Mikko
Grönberg, Leif
Puranen, Tuomas
van der Kuur, Jan
Beev, Nikolai
Salonen, Jaakko
Hazra, Dibyendu
Korpela, Seppo
Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera
title Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera
title_full Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera
title_fullStr Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera
title_full_unstemmed Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera
title_short Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera
title_sort two-stage squid amplifier for the frequency multiplexed readout of the x-ifu x-ray camera
url https://dx.doi.org/10.1109/TASC.2021.3060356
http://cds.cern.ch/record/2765832
work_keys_str_mv AT kivirantamikko twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera
AT gronbergleif twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera
AT puranentuomas twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera
AT vanderkuurjan twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera
AT beevnikolai twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera
AT salonenjaakko twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera
AT hazradibyendu twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera
AT korpelaseppo twostagesquidamplifierforthefrequencymultiplexedreadoutofthexifuxraycamera