Cargando…

TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors

Pad and strip detectors processed on high resistivity n-type magnetic Czochralski silicon (MCz-Si) were irradiated to several different fluences with protons. The pad detectors were characterized with the transient current technique (TCT) and the full-size strip detectors with a reference beam teles...

Descripción completa

Detalles Bibliográficos
Autores principales: Luukka, P, Härkönen, J, Mäenpää, T, Betchart, B, Czellar, S, Demina, R, Furgeri, A, Gotra, Y, Frey, M, Hartmann, F, Korjenevski, S, Kortelainen, M J, Lampén, T, Ledermann, B, Lemaitre, V, Liamsuwan, T, Militaru, O, Moilanen, H, Simonis, H J, Spiegel, L, Tuominen, E, Tuominiemi, J, Tuovinen, E
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2009.01.071
http://cds.cern.ch/record/2634862
_version_ 1780959816376647680
author Luukka, P
Härkönen, J
Mäenpää, T
Betchart, B
Czellar, S
Demina, R
Furgeri, A
Gotra, Y
Frey, M
Hartmann, F
Korjenevski, S
Kortelainen, M J
Lampén, T
Ledermann, B
Lemaitre, V
Liamsuwan, T
Militaru, O
Moilanen, H
Simonis, H J
Spiegel, L
Tuominen, E
Tuominiemi, J
Tuovinen, E
author_facet Luukka, P
Härkönen, J
Mäenpää, T
Betchart, B
Czellar, S
Demina, R
Furgeri, A
Gotra, Y
Frey, M
Hartmann, F
Korjenevski, S
Kortelainen, M J
Lampén, T
Ledermann, B
Lemaitre, V
Liamsuwan, T
Militaru, O
Moilanen, H
Simonis, H J
Spiegel, L
Tuominen, E
Tuominiemi, J
Tuovinen, E
author_sort Luukka, P
collection CERN
description Pad and strip detectors processed on high resistivity n-type magnetic Czochralski silicon (MCz-Si) were irradiated to several different fluences with protons. The pad detectors were characterized with the transient current technique (TCT) and the full-size strip detectors with a reference beam telescope and a 225GeV muon beam. The TCT measurements indicate a double junction structure and space charge sign inversion in MCz-Si detectors after $6 \times 10^{14} \ 1 \ \rm{MeV} n_{eq}/cm^2$ fluence. In the beam test a signal-to-noise ($S/N$) ratio of 50 was measured for a non-irradiated MCz-Si sensor, and a $S/N$ ratio of 20 for the sensors irradiated to the fluences of $1 \times 10^{14} \ 1$ and $5 \times 10^{14} \ 1 \ \rm{MeV} n_{eq}/cm^2$.
id oai-inspirehep.net-852005
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling oai-inspirehep.net-8520052019-09-30T06:29:59Zdoi:10.1016/j.nima.2009.01.071http://cds.cern.ch/record/2634862engLuukka, PHärkönen, JMäenpää, TBetchart, BCzellar, SDemina, RFurgeri, AGotra, YFrey, MHartmann, FKorjenevski, SKortelainen, M JLampén, TLedermann, BLemaitre, VLiamsuwan, TMilitaru, OMoilanen, HSimonis, H JSpiegel, LTuominen, ETuominiemi, JTuovinen, ETCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectorsDetectors and Experimental TechniquesPad and strip detectors processed on high resistivity n-type magnetic Czochralski silicon (MCz-Si) were irradiated to several different fluences with protons. The pad detectors were characterized with the transient current technique (TCT) and the full-size strip detectors with a reference beam telescope and a 225GeV muon beam. The TCT measurements indicate a double junction structure and space charge sign inversion in MCz-Si detectors after $6 \times 10^{14} \ 1 \ \rm{MeV} n_{eq}/cm^2$ fluence. In the beam test a signal-to-noise ($S/N$) ratio of 50 was measured for a non-irradiated MCz-Si sensor, and a $S/N$ ratio of 20 for the sensors irradiated to the fluences of $1 \times 10^{14} \ 1$ and $5 \times 10^{14} \ 1 \ \rm{MeV} n_{eq}/cm^2$.FERMILAB-CONF-09-677-Eoai:inspirehep.net:8520052009
spellingShingle Detectors and Experimental Techniques
Luukka, P
Härkönen, J
Mäenpää, T
Betchart, B
Czellar, S
Demina, R
Furgeri, A
Gotra, Y
Frey, M
Hartmann, F
Korjenevski, S
Kortelainen, M J
Lampén, T
Ledermann, B
Lemaitre, V
Liamsuwan, T
Militaru, O
Moilanen, H
Simonis, H J
Spiegel, L
Tuominen, E
Tuominiemi, J
Tuovinen, E
TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors
title TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors
title_full TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors
title_fullStr TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors
title_full_unstemmed TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors
title_short TCT and test beam results of irradiated magnetic Czochralski silicon (MCz-Si) detectors
title_sort tct and test beam results of irradiated magnetic czochralski silicon (mcz-si) detectors
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2009.01.071
http://cds.cern.ch/record/2634862
work_keys_str_mv AT luukkap tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT harkonenj tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT maenpaat tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT betchartb tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT czellars tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT deminar tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT furgeria tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT gotray tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT freym tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT hartmannf tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT korjenevskis tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT kortelainenmj tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT lampent tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT ledermannb tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT lemaitrev tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT liamsuwant tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT militaruo tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT moilanenh tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT simonishj tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT spiegell tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT tuominene tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT tuominiemij tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors
AT tuovinene tctandtestbeamresultsofirradiatedmagneticczochralskisiliconmczsidetectors