Cargando…

Testbeam results for the SiW electromagnetic calorimeter

A prototype of a highly granular SiW electromagnetic calorimeter composed of 6480 cells contained in a volume of 18x18x30cm^3 was installed and tested in 2006 at CERN by the CALICE collaboration. The analysis focuses on the resolution of the calor imeter to electromagnetic showers. The energy resolu...

Descripción completa

Detalles Bibliográficos
Autor principal: Faucci Giannelli, Michele
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2010.02.206
http://cds.cern.ch/record/2637376
_version_ 1780959986023661568
author Faucci Giannelli, Michele
author_facet Faucci Giannelli, Michele
author_sort Faucci Giannelli, Michele
collection CERN
description A prototype of a highly granular SiW electromagnetic calorimeter composed of 6480 cells contained in a volume of 18x18x30cm^3 was installed and tested in 2006 at CERN by the CALICE collaboration. The analysis focuses on the resolution of the calor imeter to electromagnetic showers. The energy resolution was found to be 16.6+/-0.1/E(GeV)@?1.1+/-0.1(%) while the linearity was better than 1%. The analysis on embedded electronics showed no sign of signal induced by the shower.
id oai-inspirehep.net-876947
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling oai-inspirehep.net-8769472019-09-30T06:29:59Zdoi:10.1016/j.nima.2010.02.206http://cds.cern.ch/record/2637376engFaucci Giannelli, MicheleTestbeam results for the SiW electromagnetic calorimeterDetectors and Experimental TechniquesA prototype of a highly granular SiW electromagnetic calorimeter composed of 6480 cells contained in a volume of 18x18x30cm^3 was installed and tested in 2006 at CERN by the CALICE collaboration. The analysis focuses on the resolution of the calor imeter to electromagnetic showers. The energy resolution was found to be 16.6+/-0.1/E(GeV)@?1.1+/-0.1(%) while the linearity was better than 1%. The analysis on embedded electronics showed no sign of signal induced by the shower.oai:inspirehep.net:8769472010
spellingShingle Detectors and Experimental Techniques
Faucci Giannelli, Michele
Testbeam results for the SiW electromagnetic calorimeter
title Testbeam results for the SiW electromagnetic calorimeter
title_full Testbeam results for the SiW electromagnetic calorimeter
title_fullStr Testbeam results for the SiW electromagnetic calorimeter
title_full_unstemmed Testbeam results for the SiW electromagnetic calorimeter
title_short Testbeam results for the SiW electromagnetic calorimeter
title_sort testbeam results for the siw electromagnetic calorimeter
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2010.02.206
http://cds.cern.ch/record/2637376
work_keys_str_mv AT fauccigiannellimichele testbeamresultsforthesiwelectromagneticcalorimeter