Cargando…
Performance, calibration and alignment of the CMS preshower detector
The Preshower detector, part of the CMS Endcap Electromagnetic Calorimeter, is designed to have good spatial resolution to identify the position of incoming particles. The detector was installed in CMS and commissioned in 2009. LHC collisions prov ided data used to verify the calibration of the Pres...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nuclphysbps.2011.03.153 http://cds.cern.ch/record/2002962 |
_version_ | 1780946097466769408 |
---|---|
author | Lu, Rong-Shyang |
author_facet | Lu, Rong-Shyang |
author_sort | Lu, Rong-Shyang |
collection | CERN |
description | The Preshower detector, part of the CMS Endcap Electromagnetic Calorimeter, is designed to have good spatial resolution to identify the position of incoming particles. The detector was installed in CMS and commissioned in 2009. LHC collisions prov ided data used to verify the calibration of the Preshower silicon sensors, and compare low-level observables such as energy deposits and clustering with Monte-Carlo - showing good agreement. The data also allowed an alignment measurement to be performed b etween the Preshower and the Tracker. |
id | oai-inspirehep.net-918038 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | oai-inspirehep.net-9180382019-09-30T06:29:59Zdoi:10.1016/j.nuclphysbps.2011.03.153http://cds.cern.ch/record/2002962engLu, Rong-ShyangPerformance, calibration and alignment of the CMS preshower detectorDetectors and Experimental TechniquesThe Preshower detector, part of the CMS Endcap Electromagnetic Calorimeter, is designed to have good spatial resolution to identify the position of incoming particles. The detector was installed in CMS and commissioned in 2009. LHC collisions prov ided data used to verify the calibration of the Preshower silicon sensors, and compare low-level observables such as energy deposits and clustering with Monte-Carlo - showing good agreement. The data also allowed an alignment measurement to be performed b etween the Preshower and the Tracker.oai:inspirehep.net:9180382011 |
spellingShingle | Detectors and Experimental Techniques Lu, Rong-Shyang Performance, calibration and alignment of the CMS preshower detector |
title | Performance, calibration and alignment of the CMS preshower detector |
title_full | Performance, calibration and alignment of the CMS preshower detector |
title_fullStr | Performance, calibration and alignment of the CMS preshower detector |
title_full_unstemmed | Performance, calibration and alignment of the CMS preshower detector |
title_short | Performance, calibration and alignment of the CMS preshower detector |
title_sort | performance, calibration and alignment of the cms preshower detector |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nuclphysbps.2011.03.153 http://cds.cern.ch/record/2002962 |
work_keys_str_mv | AT lurongshyang performancecalibrationandalignmentofthecmspreshowerdetector |