The alignment of the CMS silicon tracker

The complex system of the CMS all-silicon Tracker, with 15148 silicon strips and 1440 silicon pixel modules, requires sophisticated alignment procedures. In order to achieve an optimal track-parameter resolution, the position and orientation of it s modules need to be determined with a precision of...

Descripción completa

Detalles Bibliográficos
Autor principal: Aguilo, E
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nuclphysbps.2011.03.148
http://cds.cern.ch/record/2002986
Descripción
Sumario:The complex system of the CMS all-silicon Tracker, with 15148 silicon strips and 1440 silicon pixel modules, requires sophisticated alignment procedures. In order to achieve an optimal track-parameter resolution, the position and orientation of it s modules need to be determined with a precision of few micrometers. We present results of the alignment of the full Tracker, in its final position, used for the reconstruction of the first collisions recorded by the CMS experiment. The aligned geometry i s based on the analysis of several million reconstructed tracks recorded during the commissioning of the CMS experiment, both with cosmic rays and with the first proton-proton collisions. The geometry has been systematically monitored in the different per iods of operation of the CMS detector. The results have been validated by several data-driven studies (laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution) and compared with pr edictions obtained from a detailed detector simulation.