Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study

The aim of the study was to evaluate the laryngoscopes Macintosh, Miller, McCoy, Intubrite, VieScope and I-View in simulated out-of-hospital conditions when used by people without clinical experience, and to choose the one that, in the case of failure of the first intubation (FI), gives the highest...

Descripción completa

Detalles Bibliográficos
Autores principales: Ratajczyk, Paweł, Kluj, Przemysław, Dolder, Przemysław, Szmyd, Bartosz, Gaszyński, Tomasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000538/
https://www.ncbi.nlm.nih.gov/pubmed/36900666
http://dx.doi.org/10.3390/healthcare11050661
_version_ 1784903902518312960
author Ratajczyk, Paweł
Kluj, Przemysław
Dolder, Przemysław
Szmyd, Bartosz
Gaszyński, Tomasz
author_facet Ratajczyk, Paweł
Kluj, Przemysław
Dolder, Przemysław
Szmyd, Bartosz
Gaszyński, Tomasz
author_sort Ratajczyk, Paweł
collection PubMed
description The aim of the study was to evaluate the laryngoscopes Macintosh, Miller, McCoy, Intubrite, VieScope and I-View in simulated out-of-hospital conditions when used by people without clinical experience, and to choose the one that, in the case of failure of the first intubation (FI), gives the highest probability of successful second (SI) or third (TI). For FI, the highest success rate (HSR) was observed for I-View and the lowest (LSR) for Macintosh (90% vs. 60%; p < 0.001); for SI, HSR was observed for I-View and LSR for Miller (95% vs. 66,7%; p < 0001); and for TI, HSR was observed for I-View and LSR for Miller, McCoy and VieScope (98.33% vs. 70%; p < 0.001). A significant shortening of intubation time between FI and TI was observed for Macintosh (38.95 (IQR: 30.1–47.025) vs. 32.4 (IQR: 29–39.175), p = 0.0132), McCoy (39.3 (IQR: 31.1–48.15) vs. 28.75 (IQR: 26.475–35.7), p < 0.001), Intubrite (26.4 (IQR: 21.4–32.3) vs. 20.7 (IQR: 18.3–24.45), p < 0.001), and I-View (21 (IQR: 17.375–25.1) vs. 18 (IQR: 15.95–20.5), p < 0.001). According to the respondents, the easiest laryngo- scopes to use were I-View and Intubrite, while the most difficult was Miller. The study shows that I-View and Intubrite are the most useful devices, combining high efficiency with a statistically significant reduction in time between successive attempts.
format Online
Article
Text
id pubmed-10000538
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100005382023-03-11 Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study Ratajczyk, Paweł Kluj, Przemysław Dolder, Przemysław Szmyd, Bartosz Gaszyński, Tomasz Healthcare (Basel) Article The aim of the study was to evaluate the laryngoscopes Macintosh, Miller, McCoy, Intubrite, VieScope and I-View in simulated out-of-hospital conditions when used by people without clinical experience, and to choose the one that, in the case of failure of the first intubation (FI), gives the highest probability of successful second (SI) or third (TI). For FI, the highest success rate (HSR) was observed for I-View and the lowest (LSR) for Macintosh (90% vs. 60%; p < 0.001); for SI, HSR was observed for I-View and LSR for Miller (95% vs. 66,7%; p < 0001); and for TI, HSR was observed for I-View and LSR for Miller, McCoy and VieScope (98.33% vs. 70%; p < 0.001). A significant shortening of intubation time between FI and TI was observed for Macintosh (38.95 (IQR: 30.1–47.025) vs. 32.4 (IQR: 29–39.175), p = 0.0132), McCoy (39.3 (IQR: 31.1–48.15) vs. 28.75 (IQR: 26.475–35.7), p < 0.001), Intubrite (26.4 (IQR: 21.4–32.3) vs. 20.7 (IQR: 18.3–24.45), p < 0.001), and I-View (21 (IQR: 17.375–25.1) vs. 18 (IQR: 15.95–20.5), p < 0.001). According to the respondents, the easiest laryngo- scopes to use were I-View and Intubrite, while the most difficult was Miller. The study shows that I-View and Intubrite are the most useful devices, combining high efficiency with a statistically significant reduction in time between successive attempts. MDPI 2023-02-23 /pmc/articles/PMC10000538/ /pubmed/36900666 http://dx.doi.org/10.3390/healthcare11050661 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ratajczyk, Paweł
Kluj, Przemysław
Dolder, Przemysław
Szmyd, Bartosz
Gaszyński, Tomasz
Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study
title Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study
title_full Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study
title_fullStr Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study
title_full_unstemmed Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study
title_short Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study
title_sort assessment of the possibility of using the laryngoscopes macintosh, mccoy, miller, intubrite, viescope and i-view for intubation in simulated out-of-hospital conditions by people without clinical experience: a randomized crossover manikin study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000538/
https://www.ncbi.nlm.nih.gov/pubmed/36900666
http://dx.doi.org/10.3390/healthcare11050661
work_keys_str_mv AT ratajczykpaweł assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy
AT klujprzemysław assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy
AT dolderprzemysław assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy
AT szmydbartosz assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy
AT gaszynskitomasz assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy