Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study
The aim of the study was to evaluate the laryngoscopes Macintosh, Miller, McCoy, Intubrite, VieScope and I-View in simulated out-of-hospital conditions when used by people without clinical experience, and to choose the one that, in the case of failure of the first intubation (FI), gives the highest...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000538/ https://www.ncbi.nlm.nih.gov/pubmed/36900666 http://dx.doi.org/10.3390/healthcare11050661 |
_version_ | 1784903902518312960 |
---|---|
author | Ratajczyk, Paweł Kluj, Przemysław Dolder, Przemysław Szmyd, Bartosz Gaszyński, Tomasz |
author_facet | Ratajczyk, Paweł Kluj, Przemysław Dolder, Przemysław Szmyd, Bartosz Gaszyński, Tomasz |
author_sort | Ratajczyk, Paweł |
collection | PubMed |
description | The aim of the study was to evaluate the laryngoscopes Macintosh, Miller, McCoy, Intubrite, VieScope and I-View in simulated out-of-hospital conditions when used by people without clinical experience, and to choose the one that, in the case of failure of the first intubation (FI), gives the highest probability of successful second (SI) or third (TI). For FI, the highest success rate (HSR) was observed for I-View and the lowest (LSR) for Macintosh (90% vs. 60%; p < 0.001); for SI, HSR was observed for I-View and LSR for Miller (95% vs. 66,7%; p < 0001); and for TI, HSR was observed for I-View and LSR for Miller, McCoy and VieScope (98.33% vs. 70%; p < 0.001). A significant shortening of intubation time between FI and TI was observed for Macintosh (38.95 (IQR: 30.1–47.025) vs. 32.4 (IQR: 29–39.175), p = 0.0132), McCoy (39.3 (IQR: 31.1–48.15) vs. 28.75 (IQR: 26.475–35.7), p < 0.001), Intubrite (26.4 (IQR: 21.4–32.3) vs. 20.7 (IQR: 18.3–24.45), p < 0.001), and I-View (21 (IQR: 17.375–25.1) vs. 18 (IQR: 15.95–20.5), p < 0.001). According to the respondents, the easiest laryngo- scopes to use were I-View and Intubrite, while the most difficult was Miller. The study shows that I-View and Intubrite are the most useful devices, combining high efficiency with a statistically significant reduction in time between successive attempts. |
format | Online Article Text |
id | pubmed-10000538 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100005382023-03-11 Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study Ratajczyk, Paweł Kluj, Przemysław Dolder, Przemysław Szmyd, Bartosz Gaszyński, Tomasz Healthcare (Basel) Article The aim of the study was to evaluate the laryngoscopes Macintosh, Miller, McCoy, Intubrite, VieScope and I-View in simulated out-of-hospital conditions when used by people without clinical experience, and to choose the one that, in the case of failure of the first intubation (FI), gives the highest probability of successful second (SI) or third (TI). For FI, the highest success rate (HSR) was observed for I-View and the lowest (LSR) for Macintosh (90% vs. 60%; p < 0.001); for SI, HSR was observed for I-View and LSR for Miller (95% vs. 66,7%; p < 0001); and for TI, HSR was observed for I-View and LSR for Miller, McCoy and VieScope (98.33% vs. 70%; p < 0.001). A significant shortening of intubation time between FI and TI was observed for Macintosh (38.95 (IQR: 30.1–47.025) vs. 32.4 (IQR: 29–39.175), p = 0.0132), McCoy (39.3 (IQR: 31.1–48.15) vs. 28.75 (IQR: 26.475–35.7), p < 0.001), Intubrite (26.4 (IQR: 21.4–32.3) vs. 20.7 (IQR: 18.3–24.45), p < 0.001), and I-View (21 (IQR: 17.375–25.1) vs. 18 (IQR: 15.95–20.5), p < 0.001). According to the respondents, the easiest laryngo- scopes to use were I-View and Intubrite, while the most difficult was Miller. The study shows that I-View and Intubrite are the most useful devices, combining high efficiency with a statistically significant reduction in time between successive attempts. MDPI 2023-02-23 /pmc/articles/PMC10000538/ /pubmed/36900666 http://dx.doi.org/10.3390/healthcare11050661 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ratajczyk, Paweł Kluj, Przemysław Dolder, Przemysław Szmyd, Bartosz Gaszyński, Tomasz Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study |
title | Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study |
title_full | Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study |
title_fullStr | Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study |
title_full_unstemmed | Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study |
title_short | Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study |
title_sort | assessment of the possibility of using the laryngoscopes macintosh, mccoy, miller, intubrite, viescope and i-view for intubation in simulated out-of-hospital conditions by people without clinical experience: a randomized crossover manikin study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000538/ https://www.ncbi.nlm.nih.gov/pubmed/36900666 http://dx.doi.org/10.3390/healthcare11050661 |
work_keys_str_mv | AT ratajczykpaweł assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy AT klujprzemysław assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy AT dolderprzemysław assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy AT szmydbartosz assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy AT gaszynskitomasz assessmentofthepossibilityofusingthelaryngoscopesmacintoshmccoymillerintubriteviescopeandiviewforintubationinsimulatedoutofhospitalconditionsbypeoplewithoutclinicalexperiencearandomizedcrossovermanikinstudy |