Cargando…

Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals

Due to the simplicity and convenience of PPG signal acquisition, the detection of the respiration rate based on the PPG signal is more suitable for dynamic monitoring than the impedance spirometry method, but it is challenging to achieve accurate predictions from low-signal-quality PPG signals, espe...

Descripción completa

Detalles Bibliográficos
Autores principales: Dong, Xuhao, Wang, Ziyi, Cao, Liangli, Chen, Zhencheng, Liang, Yongbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000566/
https://www.ncbi.nlm.nih.gov/pubmed/36900057
http://dx.doi.org/10.3390/diagnostics13050913
_version_ 1784903909750341632
author Dong, Xuhao
Wang, Ziyi
Cao, Liangli
Chen, Zhencheng
Liang, Yongbo
author_facet Dong, Xuhao
Wang, Ziyi
Cao, Liangli
Chen, Zhencheng
Liang, Yongbo
author_sort Dong, Xuhao
collection PubMed
description Due to the simplicity and convenience of PPG signal acquisition, the detection of the respiration rate based on the PPG signal is more suitable for dynamic monitoring than the impedance spirometry method, but it is challenging to achieve accurate predictions from low-signal-quality PPG signals, especially in intensive-care patients with weak PPG signals. The goal of this study was to construct a simple model for respiration rate estimation based on PPG signals using a machine-learning approach fusing signal quality metrics to improve the accuracy of estimation despite the low-signal-quality PPG signals. In this study, we propose a method based on the whale optimization algorithm (WOA) with a hybrid relation vector machine (HRVM) to construct a highly robust model considering signal quality factors to estimate RR from PPG signals in real time. To detect the performance of the proposed model, we simultaneously recorded PPG signals and impedance respiratory rates obtained from the BIDMC dataset. The results of the respiration rate prediction model proposed in this study showed that the MAE and RMSE were 0.71 and 0.99 breaths/min, respectively, in the training set, and 1.24 and 1.79 breaths/min, respectively, in the test set. Compared without taking signal quality factors into account, MAE and RMSE are reduced by 1.28 and 1.67 breaths/min, respectively, in the training set, and reduced by 0.62 and 0.65 breaths/min in the test set. Even in the nonnormal breathing range below 12 bpm and above 24 bpm, the MAE reached 2.68 and 4.28 breaths/min, respectively, and the RMSE reached 3.52 and 5.01 breaths/min, respectively. The results show that the model that considers the PPG signal quality and respiratory quality proposed in this study has obvious advantages and application potential in predicting the respiration rate to cope with the problem of low signal quality.
format Online
Article
Text
id pubmed-10000566
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100005662023-03-11 Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals Dong, Xuhao Wang, Ziyi Cao, Liangli Chen, Zhencheng Liang, Yongbo Diagnostics (Basel) Article Due to the simplicity and convenience of PPG signal acquisition, the detection of the respiration rate based on the PPG signal is more suitable for dynamic monitoring than the impedance spirometry method, but it is challenging to achieve accurate predictions from low-signal-quality PPG signals, especially in intensive-care patients with weak PPG signals. The goal of this study was to construct a simple model for respiration rate estimation based on PPG signals using a machine-learning approach fusing signal quality metrics to improve the accuracy of estimation despite the low-signal-quality PPG signals. In this study, we propose a method based on the whale optimization algorithm (WOA) with a hybrid relation vector machine (HRVM) to construct a highly robust model considering signal quality factors to estimate RR from PPG signals in real time. To detect the performance of the proposed model, we simultaneously recorded PPG signals and impedance respiratory rates obtained from the BIDMC dataset. The results of the respiration rate prediction model proposed in this study showed that the MAE and RMSE were 0.71 and 0.99 breaths/min, respectively, in the training set, and 1.24 and 1.79 breaths/min, respectively, in the test set. Compared without taking signal quality factors into account, MAE and RMSE are reduced by 1.28 and 1.67 breaths/min, respectively, in the training set, and reduced by 0.62 and 0.65 breaths/min in the test set. Even in the nonnormal breathing range below 12 bpm and above 24 bpm, the MAE reached 2.68 and 4.28 breaths/min, respectively, and the RMSE reached 3.52 and 5.01 breaths/min, respectively. The results show that the model that considers the PPG signal quality and respiratory quality proposed in this study has obvious advantages and application potential in predicting the respiration rate to cope with the problem of low signal quality. MDPI 2023-02-28 /pmc/articles/PMC10000566/ /pubmed/36900057 http://dx.doi.org/10.3390/diagnostics13050913 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dong, Xuhao
Wang, Ziyi
Cao, Liangli
Chen, Zhencheng
Liang, Yongbo
Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals
title Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals
title_full Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals
title_fullStr Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals
title_full_unstemmed Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals
title_short Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals
title_sort whale optimization algorithm with a hybrid relation vector machine: a highly robust respiratory rate prediction model using photoplethysmography signals
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000566/
https://www.ncbi.nlm.nih.gov/pubmed/36900057
http://dx.doi.org/10.3390/diagnostics13050913
work_keys_str_mv AT dongxuhao whaleoptimizationalgorithmwithahybridrelationvectormachineahighlyrobustrespiratoryratepredictionmodelusingphotoplethysmographysignals
AT wangziyi whaleoptimizationalgorithmwithahybridrelationvectormachineahighlyrobustrespiratoryratepredictionmodelusingphotoplethysmographysignals
AT caoliangli whaleoptimizationalgorithmwithahybridrelationvectormachineahighlyrobustrespiratoryratepredictionmodelusingphotoplethysmographysignals
AT chenzhencheng whaleoptimizationalgorithmwithahybridrelationvectormachineahighlyrobustrespiratoryratepredictionmodelusingphotoplethysmographysignals
AT liangyongbo whaleoptimizationalgorithmwithahybridrelationvectormachineahighlyrobustrespiratoryratepredictionmodelusingphotoplethysmographysignals