Cargando…

Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study

The professional association has already developed guidelines on the appropriate use of handheld ultrasound devices, especially in an emergency setting. Handheld ultrasound devices are seen as the ‘stethoscope of the future’ to assist in physical examination. Our exploratory study evaluated whether...

Descripción completa

Detalles Bibliográficos
Autores principales: Haji-Hassan, Mariam, Duțu, Bogdan, Bolboacă, Sorana D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000668/
https://www.ncbi.nlm.nih.gov/pubmed/36899997
http://dx.doi.org/10.3390/diagnostics13050853
_version_ 1784903936110493696
author Haji-Hassan, Mariam
Duțu, Bogdan
Bolboacă, Sorana D.
author_facet Haji-Hassan, Mariam
Duțu, Bogdan
Bolboacă, Sorana D.
author_sort Haji-Hassan, Mariam
collection PubMed
description The professional association has already developed guidelines on the appropriate use of handheld ultrasound devices, especially in an emergency setting. Handheld ultrasound devices are seen as the ‘stethoscope of the future’ to assist in physical examination. Our exploratory study evaluated whether the measurements of cardiovascular structures and the agreement in identifying aortic, mitral, and tricuspid valve pathology made by a resident with a handheld device (HH, Kosmos Torso-One) reach the results reported by an experienced examiner who used a high-end device (STD). Patients referred for cardiology examination in a single center from June to August 2022 were eligible for the study. Patients who agreed to participate underwent two heart ultrasound examinations scanned by the same two operators. A cardiology resident performed the first examination with a HH ultrasound device, and an experienced examiner performed the second examination with an STD device. Forty-three consecutive patients were eligible, and forty-two were included in the study. One obese patient was excluded because none of the examiners succeeded in performing the heart examination. The measurements obtained with HH were generally higher than those obtained with STD, with the highest mean difference of 0.4 mm, but without significant differences (all 95% confidence intervals of the differences contain the value of 0). For valvular disease, the lowest agreement was observed for mitral valve regurgitation (26/42, with a Kappa concordance coefficient of 0.5321), which was missed in almost half of the patients with mild regurgitation and underestimated in half of the patients with moderate mitral regurgitation. The measurements performed by the resident with the handheld Kosmos Torso-One device showed high concordance with those conducted by the experienced examiner with a larger high-end ultrasound device. The learning curve of the resident could explain the limited performance in identifying valvular pathologies between examiners.
format Online
Article
Text
id pubmed-10000668
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100006682023-03-11 Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study Haji-Hassan, Mariam Duțu, Bogdan Bolboacă, Sorana D. Diagnostics (Basel) Article The professional association has already developed guidelines on the appropriate use of handheld ultrasound devices, especially in an emergency setting. Handheld ultrasound devices are seen as the ‘stethoscope of the future’ to assist in physical examination. Our exploratory study evaluated whether the measurements of cardiovascular structures and the agreement in identifying aortic, mitral, and tricuspid valve pathology made by a resident with a handheld device (HH, Kosmos Torso-One) reach the results reported by an experienced examiner who used a high-end device (STD). Patients referred for cardiology examination in a single center from June to August 2022 were eligible for the study. Patients who agreed to participate underwent two heart ultrasound examinations scanned by the same two operators. A cardiology resident performed the first examination with a HH ultrasound device, and an experienced examiner performed the second examination with an STD device. Forty-three consecutive patients were eligible, and forty-two were included in the study. One obese patient was excluded because none of the examiners succeeded in performing the heart examination. The measurements obtained with HH were generally higher than those obtained with STD, with the highest mean difference of 0.4 mm, but without significant differences (all 95% confidence intervals of the differences contain the value of 0). For valvular disease, the lowest agreement was observed for mitral valve regurgitation (26/42, with a Kappa concordance coefficient of 0.5321), which was missed in almost half of the patients with mild regurgitation and underestimated in half of the patients with moderate mitral regurgitation. The measurements performed by the resident with the handheld Kosmos Torso-One device showed high concordance with those conducted by the experienced examiner with a larger high-end ultrasound device. The learning curve of the resident could explain the limited performance in identifying valvular pathologies between examiners. MDPI 2023-02-23 /pmc/articles/PMC10000668/ /pubmed/36899997 http://dx.doi.org/10.3390/diagnostics13050853 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Haji-Hassan, Mariam
Duțu, Bogdan
Bolboacă, Sorana D.
Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study
title Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study
title_full Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study
title_fullStr Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study
title_full_unstemmed Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study
title_short Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study
title_sort handheld echocardiography measurements concordance and findings agreement: an exploratory study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000668/
https://www.ncbi.nlm.nih.gov/pubmed/36899997
http://dx.doi.org/10.3390/diagnostics13050853
work_keys_str_mv AT hajihassanmariam handheldechocardiographymeasurementsconcordanceandfindingsagreementanexploratorystudy
AT dutubogdan handheldechocardiographymeasurementsconcordanceandfindingsagreementanexploratorystudy
AT bolboacasoranad handheldechocardiographymeasurementsconcordanceandfindingsagreementanexploratorystudy