Cargando…

Simulation Experiment Research of Mine Roadway Simulating Test Device with Adjustable Wind Velocity and Temperature and Humidity

The design and development process of wind velocity sensors for mining has been a challenging task due to the complexity of a large number of field tests. To resolve this problem, this study aimed to provide a comprehensive test device for the design and development of high-precision wind velocities...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Lindong, Du, Cuifeng, Wang, Yuan, Chen, Jianwu, Yang, Bin, Jin, Weibo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10001832/
https://www.ncbi.nlm.nih.gov/pubmed/36901065
http://dx.doi.org/10.3390/ijerph20054057
Descripción
Sumario:The design and development process of wind velocity sensors for mining has been a challenging task due to the complexity of a large number of field tests. To resolve this problem, this study aimed to provide a comprehensive test device for the design and development of high-precision wind velocities sensor for mining. Through a combination of experiments and computational fluid dynamics (CFD), a device that can simulate the mine roadway environment was developed. The device can control the temperature, humidity, and wind velocity parameters to fully replicate the mine roadway environment. It gives designers and developers of high-precision wind velocity sensors for mining a rational and scientific testing environment. In order to quantitatively define the uniformity of air flow in the mine highway section, the research introduced the non-uniformity determination method. The approach was expanded to assess the cross-sectional uniformity of temperature and humidity. The wind velocity within the machine can increase to 8.5 m/s by selecting the right kind of fan. The minimum wind velocity non-uniformity at this moment is 2.30%. The device’s internal temperature can be raised to 38.23 °C and its humidity level can be increased to 95.09% by carefully crafting the rectifier orifice plate’s structure. At this time, the lowest temperature non-uniformity is 2.22%, and the lowest humidity non-uniformity is 2.40%. The device’s average wind velocity is 4.37 m/s, its average temperature is 37.7 °C, as well as its average humidity is 95%, per the emulate results. The device’s non-uniformity in wind velocity, temperature, and humidity is 2.89%, 1.34%, and 2.23%, respectively. It is capable of simulating the mine roadway environment in its entirety.