Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing

Background: Partial weight-bearing after operatively treated fractures has been the standard of care over the past decades. Recent studies report on better rehabilitation and faster return to daily life in case of immediate weight-bearing as tolerated. To allow early weight-bearing, osteosynthesis n...

Descripción completa

Detalles Bibliográficos
Autores principales: Förch, Stefan, Sandriesser, Sabrina, von Rüden, Christian, Mayr, Edgar, Augat, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10002559/
https://www.ncbi.nlm.nih.gov/pubmed/36902557
http://dx.doi.org/10.3390/jcm12051770
_version_ 1784904417802190848
author Förch, Stefan
Sandriesser, Sabrina
von Rüden, Christian
Mayr, Edgar
Augat, Peter
author_facet Förch, Stefan
Sandriesser, Sabrina
von Rüden, Christian
Mayr, Edgar
Augat, Peter
author_sort Förch, Stefan
collection PubMed
description Background: Partial weight-bearing after operatively treated fractures has been the standard of care over the past decades. Recent studies report on better rehabilitation and faster return to daily life in case of immediate weight-bearing as tolerated. To allow early weight-bearing, osteosynthesis needs to provide sufficient mechanical stability. The purpose of this study was to investigate the stabilizing benefits of additive cerclage wiring in combination with intramedullary nailing of distal tibia fractures. Methods: In 14 synthetic tibiae, a reproducible distal spiral fracture was treated by intramedullary nailing. In half of the samples, the fracture was further stabilized by additional cerclage wiring. Under clinically relevant partial and full weight-bearing loads the samples were biomechanically tested and axial construct stiffness as well as interfragmentary movements were assessed. Subsequently, a 5 mm fracture gap was created to simulate insufficient reduction, and tests were repeated. Results: Intramedullary nails offer already high axial stability. Thus, axial construct stiffness cannot be significantly enhanced by an additive cerclage (2858 ± 958 N/mm NailOnly vs. 3727 ± 793 N/mm Nail + Cable; p = 0.089). Under full weight-bearing loads, additive cerclage wiring in well-reduced fractures significantly reduced shear (p = 0.002) and torsional movements (p = 0.013) and showed similar low movements as under partial weight-bearing (shear 0.3 mm, p = 0.073; torsion 1.1°, p = 0.085). In contrast, additional cerclage had no stabilizing effect in large fracture gaps. Conclusions: In well-reduced spiral fractures of the distal tibia, the construct stability of intramedullary nailing can be further increased by additional cerclage wiring. From a biomechanical point of view, augmentation of the primary implant reduced shear movement sufficiently to allow immediate weight-bearing as tolerated. Especially, elderly patients would benefit from early post-operative mobilization, which allows for accelerated rehabilitation and a faster return to daily activities.
format Online
Article
Text
id pubmed-10002559
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100025592023-03-11 Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing Förch, Stefan Sandriesser, Sabrina von Rüden, Christian Mayr, Edgar Augat, Peter J Clin Med Article Background: Partial weight-bearing after operatively treated fractures has been the standard of care over the past decades. Recent studies report on better rehabilitation and faster return to daily life in case of immediate weight-bearing as tolerated. To allow early weight-bearing, osteosynthesis needs to provide sufficient mechanical stability. The purpose of this study was to investigate the stabilizing benefits of additive cerclage wiring in combination with intramedullary nailing of distal tibia fractures. Methods: In 14 synthetic tibiae, a reproducible distal spiral fracture was treated by intramedullary nailing. In half of the samples, the fracture was further stabilized by additional cerclage wiring. Under clinically relevant partial and full weight-bearing loads the samples were biomechanically tested and axial construct stiffness as well as interfragmentary movements were assessed. Subsequently, a 5 mm fracture gap was created to simulate insufficient reduction, and tests were repeated. Results: Intramedullary nails offer already high axial stability. Thus, axial construct stiffness cannot be significantly enhanced by an additive cerclage (2858 ± 958 N/mm NailOnly vs. 3727 ± 793 N/mm Nail + Cable; p = 0.089). Under full weight-bearing loads, additive cerclage wiring in well-reduced fractures significantly reduced shear (p = 0.002) and torsional movements (p = 0.013) and showed similar low movements as under partial weight-bearing (shear 0.3 mm, p = 0.073; torsion 1.1°, p = 0.085). In contrast, additional cerclage had no stabilizing effect in large fracture gaps. Conclusions: In well-reduced spiral fractures of the distal tibia, the construct stability of intramedullary nailing can be further increased by additional cerclage wiring. From a biomechanical point of view, augmentation of the primary implant reduced shear movement sufficiently to allow immediate weight-bearing as tolerated. Especially, elderly patients would benefit from early post-operative mobilization, which allows for accelerated rehabilitation and a faster return to daily activities. MDPI 2023-02-22 /pmc/articles/PMC10002559/ /pubmed/36902557 http://dx.doi.org/10.3390/jcm12051770 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Förch, Stefan
Sandriesser, Sabrina
von Rüden, Christian
Mayr, Edgar
Augat, Peter
Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing
title Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing
title_full Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing
title_fullStr Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing
title_full_unstemmed Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing
title_short Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing
title_sort cerclage wiring improves biomechanical stability in distal tibia spiral fractures treated by intramedullary nailing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10002559/
https://www.ncbi.nlm.nih.gov/pubmed/36902557
http://dx.doi.org/10.3390/jcm12051770
work_keys_str_mv AT forchstefan cerclagewiringimprovesbiomechanicalstabilityindistaltibiaspiralfracturestreatedbyintramedullarynailing
AT sandriessersabrina cerclagewiringimprovesbiomechanicalstabilityindistaltibiaspiralfracturestreatedbyintramedullarynailing
AT vonrudenchristian cerclagewiringimprovesbiomechanicalstabilityindistaltibiaspiralfracturestreatedbyintramedullarynailing
AT mayredgar cerclagewiringimprovesbiomechanicalstabilityindistaltibiaspiralfracturestreatedbyintramedullarynailing
AT augatpeter cerclagewiringimprovesbiomechanicalstabilityindistaltibiaspiralfracturestreatedbyintramedullarynailing