Cargando…

Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation

The aim of this study was to analyze the refraction and iris capture tendency regarding the fixation position with respect to the intrascleral fixation (ISF) of intraocular lenses. Consecutive patients who underwent ISF 1.5 mm (ISF 1.5, 45 eyes) and 2.0 mm (ISF 2.0, 55 eyes) from the corneal limbus...

Descripción completa

Detalles Bibliográficos
Autores principales: Noguchi, Santaro, Nakakura, Shunsuke, Noguchi, Asuka, Tabuchi, Hitoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003268/
https://www.ncbi.nlm.nih.gov/pubmed/36902602
http://dx.doi.org/10.3390/jcm12051815
_version_ 1784904565655601152
author Noguchi, Santaro
Nakakura, Shunsuke
Noguchi, Asuka
Tabuchi, Hitoshi
author_facet Noguchi, Santaro
Nakakura, Shunsuke
Noguchi, Asuka
Tabuchi, Hitoshi
author_sort Noguchi, Santaro
collection PubMed
description The aim of this study was to analyze the refraction and iris capture tendency regarding the fixation position with respect to the intrascleral fixation (ISF) of intraocular lenses. Consecutive patients who underwent ISF 1.5 mm (ISF 1.5, 45 eyes) and 2.0 mm (ISF 2.0, 55 eyes) from the corneal limbus with NX60, as well as those who underwent normal phacoemulsification with in-the-bag ZCB00V (ZCB, 50 eyes), were enrolled. The anterior chamber depth (post-op ACD), the estimated ACD when using the SRK/T (post-op ACD—predicted ACD), and the refractive error (post-op MRSE, and the predicted MRSE) were all calculated. In addition, the postoperative iris capture was also investigated. The post-op MRSE—predicted MRSE values were: −0.59, 0.02, and 0.00 D (ISF 1.5, ISF 2.0, and ZCB) (p < 0.05, between ISF 1.5 vs. ISF 2.0 and ZCB); the post-op ACD values were: 4.00, 4.17, and 4.29 mm (p < 0.05, ISF 1.5 vs. ZCB); and the post-op ACD—predicted ACD values were: −2.03, −1.98, and −1.60 mm (p < 0.05, between ZCB vs. ISF 1.5 and ISF 2.0). The iris capture occurred in four eyes with regard to ISF 1.5 and three eyes with ISF 2.0 (p = 0.52). Moreover, ISF 2.0 possessed 0.6D hyperopia and 0.17 mm deeper anterior chamber depth. The refractive error of ISF 2.0 was less than that of ISF 1.5. Lastly, no significant iris capture onset was noted between ISF 1.5 mm and 2.0 mm.
format Online
Article
Text
id pubmed-10003268
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100032682023-03-11 Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation Noguchi, Santaro Nakakura, Shunsuke Noguchi, Asuka Tabuchi, Hitoshi J Clin Med Article The aim of this study was to analyze the refraction and iris capture tendency regarding the fixation position with respect to the intrascleral fixation (ISF) of intraocular lenses. Consecutive patients who underwent ISF 1.5 mm (ISF 1.5, 45 eyes) and 2.0 mm (ISF 2.0, 55 eyes) from the corneal limbus with NX60, as well as those who underwent normal phacoemulsification with in-the-bag ZCB00V (ZCB, 50 eyes), were enrolled. The anterior chamber depth (post-op ACD), the estimated ACD when using the SRK/T (post-op ACD—predicted ACD), and the refractive error (post-op MRSE, and the predicted MRSE) were all calculated. In addition, the postoperative iris capture was also investigated. The post-op MRSE—predicted MRSE values were: −0.59, 0.02, and 0.00 D (ISF 1.5, ISF 2.0, and ZCB) (p < 0.05, between ISF 1.5 vs. ISF 2.0 and ZCB); the post-op ACD values were: 4.00, 4.17, and 4.29 mm (p < 0.05, ISF 1.5 vs. ZCB); and the post-op ACD—predicted ACD values were: −2.03, −1.98, and −1.60 mm (p < 0.05, between ZCB vs. ISF 1.5 and ISF 2.0). The iris capture occurred in four eyes with regard to ISF 1.5 and three eyes with ISF 2.0 (p = 0.52). Moreover, ISF 2.0 possessed 0.6D hyperopia and 0.17 mm deeper anterior chamber depth. The refractive error of ISF 2.0 was less than that of ISF 1.5. Lastly, no significant iris capture onset was noted between ISF 1.5 mm and 2.0 mm. MDPI 2023-02-24 /pmc/articles/PMC10003268/ /pubmed/36902602 http://dx.doi.org/10.3390/jcm12051815 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Noguchi, Santaro
Nakakura, Shunsuke
Noguchi, Asuka
Tabuchi, Hitoshi
Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation
title Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation
title_full Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation
title_fullStr Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation
title_full_unstemmed Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation
title_short Relationship between Postoperative Anterior Chamber Depth and Refraction Based on the Haptic Fix Position in Intraocular Lens Intrascleral Fixation
title_sort relationship between postoperative anterior chamber depth and refraction based on the haptic fix position in intraocular lens intrascleral fixation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10003268/
https://www.ncbi.nlm.nih.gov/pubmed/36902602
http://dx.doi.org/10.3390/jcm12051815
work_keys_str_mv AT noguchisantaro relationshipbetweenpostoperativeanteriorchamberdepthandrefractionbasedonthehapticfixpositioninintraocularlensintrascleralfixation
AT nakakurashunsuke relationshipbetweenpostoperativeanteriorchamberdepthandrefractionbasedonthehapticfixpositioninintraocularlensintrascleralfixation
AT noguchiasuka relationshipbetweenpostoperativeanteriorchamberdepthandrefractionbasedonthehapticfixpositioninintraocularlensintrascleralfixation
AT tabuchihitoshi relationshipbetweenpostoperativeanteriorchamberdepthandrefractionbasedonthehapticfixpositioninintraocularlensintrascleralfixation