Cargando…
Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up
Background: We have previously reported that the incidence of postoperative conduction disorders, especially left bundle branch block (LBBB), after implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis (Edwards Lifesciences, Irvine, CA, USA), was significantly increased compared...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10004204/ https://www.ncbi.nlm.nih.gov/pubmed/36902870 http://dx.doi.org/10.3390/jcm12052083 |
_version_ | 1784904774972342272 |
---|---|
author | Mogilansky, Christian Massoudy, Parwis Czesla, Markus Balan, Robert |
author_facet | Mogilansky, Christian Massoudy, Parwis Czesla, Markus Balan, Robert |
author_sort | Mogilansky, Christian |
collection | PubMed |
description | Background: We have previously reported that the incidence of postoperative conduction disorders, especially left bundle branch block (LBBB), after implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis (Edwards Lifesciences, Irvine, CA, USA), was significantly increased compared with conventional aortic valve replacement. We were now interested in how these disorders behaved at intermediate follow-up. Methods: All 87 patients who had undergone surgical aortic valve replacement (SAVR) using the rapid deployment Intuity™ Elite prosthesis and were shown to have conduction disorders at the time of hospital discharge were followed up after surgery. These patients’ ECGs were recorded at least 1 year after surgery, and the persistence of the new postoperative conduction disorders was assessed. Results: At hospital discharge, 48.1% of the patients had developed new postoperative conduction disorders, with LBBB being the predominant conduction disturbance (36.5%). At medium-term follow-up (526 days, standard deviation (SD) = 169.6, standard error (SE) = 19.3 days, respectively), 44% of the new LBBB and 50% of the new right bundle branch block (RBBB) had disappeared. There was no new atrio-ventricular block III (AVB III) that occurred. One new pacemaker (PM) was implanted during follow-up because of AVB II Mobitz type II. Conclusions: At medium-term follow-up after the implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis, the number of new postoperative conduction disorders, especially LBBB, has considerably decreased but remains high. The incidence of postoperative AV block III remained stable. |
format | Online Article Text |
id | pubmed-10004204 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100042042023-03-11 Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up Mogilansky, Christian Massoudy, Parwis Czesla, Markus Balan, Robert J Clin Med Article Background: We have previously reported that the incidence of postoperative conduction disorders, especially left bundle branch block (LBBB), after implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis (Edwards Lifesciences, Irvine, CA, USA), was significantly increased compared with conventional aortic valve replacement. We were now interested in how these disorders behaved at intermediate follow-up. Methods: All 87 patients who had undergone surgical aortic valve replacement (SAVR) using the rapid deployment Intuity™ Elite prosthesis and were shown to have conduction disorders at the time of hospital discharge were followed up after surgery. These patients’ ECGs were recorded at least 1 year after surgery, and the persistence of the new postoperative conduction disorders was assessed. Results: At hospital discharge, 48.1% of the patients had developed new postoperative conduction disorders, with LBBB being the predominant conduction disturbance (36.5%). At medium-term follow-up (526 days, standard deviation (SD) = 169.6, standard error (SE) = 19.3 days, respectively), 44% of the new LBBB and 50% of the new right bundle branch block (RBBB) had disappeared. There was no new atrio-ventricular block III (AVB III) that occurred. One new pacemaker (PM) was implanted during follow-up because of AVB II Mobitz type II. Conclusions: At medium-term follow-up after the implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis, the number of new postoperative conduction disorders, especially LBBB, has considerably decreased but remains high. The incidence of postoperative AV block III remained stable. MDPI 2023-03-06 /pmc/articles/PMC10004204/ /pubmed/36902870 http://dx.doi.org/10.3390/jcm12052083 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mogilansky, Christian Massoudy, Parwis Czesla, Markus Balan, Robert Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up |
title | Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up |
title_full | Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up |
title_fullStr | Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up |
title_full_unstemmed | Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up |
title_short | Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up |
title_sort | conduction disorders after surgical aortic valve replacement using a rapid deployment aortic valve prosthesis: medium-term follow-up |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10004204/ https://www.ncbi.nlm.nih.gov/pubmed/36902870 http://dx.doi.org/10.3390/jcm12052083 |
work_keys_str_mv | AT mogilanskychristian conductiondisordersaftersurgicalaorticvalvereplacementusingarapiddeploymentaorticvalveprosthesismediumtermfollowup AT massoudyparwis conductiondisordersaftersurgicalaorticvalvereplacementusingarapiddeploymentaorticvalveprosthesismediumtermfollowup AT czeslamarkus conductiondisordersaftersurgicalaorticvalvereplacementusingarapiddeploymentaorticvalveprosthesismediumtermfollowup AT balanrobert conductiondisordersaftersurgicalaorticvalvereplacementusingarapiddeploymentaorticvalveprosthesismediumtermfollowup |