Cargando…
A novel standardized approach for the 3D evaluation of upper eyelid area and volume
BACKGROUND: Three-dimensional (3D) surface imaging and morphometrics are becoming the preferred craniofacial surface imaging modality. However, as a unique advantage of 3D imaging, areal and volumetric measurements have been rarely conducted and validated for evaluating soft tissue change in the per...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006124/ https://www.ncbi.nlm.nih.gov/pubmed/36915328 http://dx.doi.org/10.21037/qims-22-589 |
_version_ | 1784905243675328512 |
---|---|
author | Guo, Yongwei Rokohl, Alexander C. Fan, Wanlin Theodosiou, Rodothea Li, Xueting Lou, Lixia Gao, Tao Lin, Ming Yao, Ke Heindl, Ludwig M. |
author_facet | Guo, Yongwei Rokohl, Alexander C. Fan, Wanlin Theodosiou, Rodothea Li, Xueting Lou, Lixia Gao, Tao Lin, Ming Yao, Ke Heindl, Ludwig M. |
author_sort | Guo, Yongwei |
collection | PubMed |
description | BACKGROUND: Three-dimensional (3D) surface imaging and morphometrics are becoming the preferred craniofacial surface imaging modality. However, as a unique advantage of 3D imaging, areal and volumetric measurements have been rarely conducted and validated for evaluating soft tissue change in the periocular region, especially the upper eyelids. Therefore, based on an existing periocular landmark identification strategy, we proposed a novel modified method to define a standardized upper eyelid region for areal and volumetric measurements and validate its reliability for future clinical application. METHODS: Forty-four healthy adult volunteers were enrolled in this cross-sectional study. Three-dimensional facial images were taken with a 3D imaging system. Subsequently, the upper eyelid region selection and areal and volumetric measurements were conducted using a modified landmarks localization strategy to evaluate their intrarater, interrater, and intramethod reliability. RESULTS: Areal measurement of the upper eyelid revealed highly reliable outcomes for intraclass correlation coefficient (ICC), mean absolute difference (MAD), relative error measurement (REM), technical error of measurement (TEM), and relative technical error of measurement (%TEM) of 0.982, 0.1620 cm(2), 2.9%, 0.1510 cm(2), and 2.7% for intrarater reliability, respectively; 0.969, 0.2076 cm(2), 3.7%, 0.1930 cm(2), and 3.5% for interrater reliability, respectively; and 0.917, 0.3636 cm(2), 6.5%, 0.3354 cm(2), and 6.0% for intramethod reliability, respectively. Unsatisfactory results were found for the volumetric measurement of the upper eyelid: the ICC, MAD, REM, TEM, and %TEM estimates for intrarater reliability were 0.992, 0.2299 mL, 10.3%, 0.2414 mL, and 10.8%, respectively; for interrater reliability, these values were 0.985, 0.2749 mL, 12.3%, 0.3253 mL, and 14.6%, respectively; and for intramethod reliability, these values were 0.433, 1.6716 mL, 77.9%, 2.0615 mL, and 96.1%, respectively. CONCLUSIONS: This is the first study to propose a standardized upper eyelid region selection strategy and simultaneously validate its reliability for 3D areal and volumetric measurements. This study confirmed the high-level reliability of areal measurement and poor reliability of volumetric measurement based on direct measurements using a single image, which may provide better results when this method is combined with the image overlapping and registration procedure. However, this is subject to further validation. Nonetheless, this method could provide quantitative areal and volumetric data on the upper eyelids and might have widespread application potential in the future. |
format | Online Article Text |
id | pubmed-10006124 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-100061242023-03-12 A novel standardized approach for the 3D evaluation of upper eyelid area and volume Guo, Yongwei Rokohl, Alexander C. Fan, Wanlin Theodosiou, Rodothea Li, Xueting Lou, Lixia Gao, Tao Lin, Ming Yao, Ke Heindl, Ludwig M. Quant Imaging Med Surg Original Article BACKGROUND: Three-dimensional (3D) surface imaging and morphometrics are becoming the preferred craniofacial surface imaging modality. However, as a unique advantage of 3D imaging, areal and volumetric measurements have been rarely conducted and validated for evaluating soft tissue change in the periocular region, especially the upper eyelids. Therefore, based on an existing periocular landmark identification strategy, we proposed a novel modified method to define a standardized upper eyelid region for areal and volumetric measurements and validate its reliability for future clinical application. METHODS: Forty-four healthy adult volunteers were enrolled in this cross-sectional study. Three-dimensional facial images were taken with a 3D imaging system. Subsequently, the upper eyelid region selection and areal and volumetric measurements were conducted using a modified landmarks localization strategy to evaluate their intrarater, interrater, and intramethod reliability. RESULTS: Areal measurement of the upper eyelid revealed highly reliable outcomes for intraclass correlation coefficient (ICC), mean absolute difference (MAD), relative error measurement (REM), technical error of measurement (TEM), and relative technical error of measurement (%TEM) of 0.982, 0.1620 cm(2), 2.9%, 0.1510 cm(2), and 2.7% for intrarater reliability, respectively; 0.969, 0.2076 cm(2), 3.7%, 0.1930 cm(2), and 3.5% for interrater reliability, respectively; and 0.917, 0.3636 cm(2), 6.5%, 0.3354 cm(2), and 6.0% for intramethod reliability, respectively. Unsatisfactory results were found for the volumetric measurement of the upper eyelid: the ICC, MAD, REM, TEM, and %TEM estimates for intrarater reliability were 0.992, 0.2299 mL, 10.3%, 0.2414 mL, and 10.8%, respectively; for interrater reliability, these values were 0.985, 0.2749 mL, 12.3%, 0.3253 mL, and 14.6%, respectively; and for intramethod reliability, these values were 0.433, 1.6716 mL, 77.9%, 2.0615 mL, and 96.1%, respectively. CONCLUSIONS: This is the first study to propose a standardized upper eyelid region selection strategy and simultaneously validate its reliability for 3D areal and volumetric measurements. This study confirmed the high-level reliability of areal measurement and poor reliability of volumetric measurement based on direct measurements using a single image, which may provide better results when this method is combined with the image overlapping and registration procedure. However, this is subject to further validation. Nonetheless, this method could provide quantitative areal and volumetric data on the upper eyelids and might have widespread application potential in the future. AME Publishing Company 2023-02-10 2023-03-01 /pmc/articles/PMC10006124/ /pubmed/36915328 http://dx.doi.org/10.21037/qims-22-589 Text en 2023 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Guo, Yongwei Rokohl, Alexander C. Fan, Wanlin Theodosiou, Rodothea Li, Xueting Lou, Lixia Gao, Tao Lin, Ming Yao, Ke Heindl, Ludwig M. A novel standardized approach for the 3D evaluation of upper eyelid area and volume |
title | A novel standardized approach for the 3D evaluation of upper eyelid area and volume |
title_full | A novel standardized approach for the 3D evaluation of upper eyelid area and volume |
title_fullStr | A novel standardized approach for the 3D evaluation of upper eyelid area and volume |
title_full_unstemmed | A novel standardized approach for the 3D evaluation of upper eyelid area and volume |
title_short | A novel standardized approach for the 3D evaluation of upper eyelid area and volume |
title_sort | novel standardized approach for the 3d evaluation of upper eyelid area and volume |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006124/ https://www.ncbi.nlm.nih.gov/pubmed/36915328 http://dx.doi.org/10.21037/qims-22-589 |
work_keys_str_mv | AT guoyongwei anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT rokohlalexanderc anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT fanwanlin anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT theodosiourodothea anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT lixueting anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT loulixia anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT gaotao anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT linming anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT yaoke anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT heindlludwigm anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT guoyongwei novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT rokohlalexanderc novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT fanwanlin novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT theodosiourodothea novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT lixueting novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT loulixia novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT gaotao novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT linming novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT yaoke novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume AT heindlludwigm novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume |