Cargando…

A novel standardized approach for the 3D evaluation of upper eyelid area and volume

BACKGROUND: Three-dimensional (3D) surface imaging and morphometrics are becoming the preferred craniofacial surface imaging modality. However, as a unique advantage of 3D imaging, areal and volumetric measurements have been rarely conducted and validated for evaluating soft tissue change in the per...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Yongwei, Rokohl, Alexander C., Fan, Wanlin, Theodosiou, Rodothea, Li, Xueting, Lou, Lixia, Gao, Tao, Lin, Ming, Yao, Ke, Heindl, Ludwig M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006124/
https://www.ncbi.nlm.nih.gov/pubmed/36915328
http://dx.doi.org/10.21037/qims-22-589
_version_ 1784905243675328512
author Guo, Yongwei
Rokohl, Alexander C.
Fan, Wanlin
Theodosiou, Rodothea
Li, Xueting
Lou, Lixia
Gao, Tao
Lin, Ming
Yao, Ke
Heindl, Ludwig M.
author_facet Guo, Yongwei
Rokohl, Alexander C.
Fan, Wanlin
Theodosiou, Rodothea
Li, Xueting
Lou, Lixia
Gao, Tao
Lin, Ming
Yao, Ke
Heindl, Ludwig M.
author_sort Guo, Yongwei
collection PubMed
description BACKGROUND: Three-dimensional (3D) surface imaging and morphometrics are becoming the preferred craniofacial surface imaging modality. However, as a unique advantage of 3D imaging, areal and volumetric measurements have been rarely conducted and validated for evaluating soft tissue change in the periocular region, especially the upper eyelids. Therefore, based on an existing periocular landmark identification strategy, we proposed a novel modified method to define a standardized upper eyelid region for areal and volumetric measurements and validate its reliability for future clinical application. METHODS: Forty-four healthy adult volunteers were enrolled in this cross-sectional study. Three-dimensional facial images were taken with a 3D imaging system. Subsequently, the upper eyelid region selection and areal and volumetric measurements were conducted using a modified landmarks localization strategy to evaluate their intrarater, interrater, and intramethod reliability. RESULTS: Areal measurement of the upper eyelid revealed highly reliable outcomes for intraclass correlation coefficient (ICC), mean absolute difference (MAD), relative error measurement (REM), technical error of measurement (TEM), and relative technical error of measurement (%TEM) of 0.982, 0.1620 cm(2), 2.9%, 0.1510 cm(2), and 2.7% for intrarater reliability, respectively; 0.969, 0.2076 cm(2), 3.7%, 0.1930 cm(2), and 3.5% for interrater reliability, respectively; and 0.917, 0.3636 cm(2), 6.5%, 0.3354 cm(2), and 6.0% for intramethod reliability, respectively. Unsatisfactory results were found for the volumetric measurement of the upper eyelid: the ICC, MAD, REM, TEM, and %TEM estimates for intrarater reliability were 0.992, 0.2299 mL, 10.3%, 0.2414 mL, and 10.8%, respectively; for interrater reliability, these values were 0.985, 0.2749 mL, 12.3%, 0.3253 mL, and 14.6%, respectively; and for intramethod reliability, these values were 0.433, 1.6716 mL, 77.9%, 2.0615 mL, and 96.1%, respectively. CONCLUSIONS: This is the first study to propose a standardized upper eyelid region selection strategy and simultaneously validate its reliability for 3D areal and volumetric measurements. This study confirmed the high-level reliability of areal measurement and poor reliability of volumetric measurement based on direct measurements using a single image, which may provide better results when this method is combined with the image overlapping and registration procedure. However, this is subject to further validation. Nonetheless, this method could provide quantitative areal and volumetric data on the upper eyelids and might have widespread application potential in the future.
format Online
Article
Text
id pubmed-10006124
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-100061242023-03-12 A novel standardized approach for the 3D evaluation of upper eyelid area and volume Guo, Yongwei Rokohl, Alexander C. Fan, Wanlin Theodosiou, Rodothea Li, Xueting Lou, Lixia Gao, Tao Lin, Ming Yao, Ke Heindl, Ludwig M. Quant Imaging Med Surg Original Article BACKGROUND: Three-dimensional (3D) surface imaging and morphometrics are becoming the preferred craniofacial surface imaging modality. However, as a unique advantage of 3D imaging, areal and volumetric measurements have been rarely conducted and validated for evaluating soft tissue change in the periocular region, especially the upper eyelids. Therefore, based on an existing periocular landmark identification strategy, we proposed a novel modified method to define a standardized upper eyelid region for areal and volumetric measurements and validate its reliability for future clinical application. METHODS: Forty-four healthy adult volunteers were enrolled in this cross-sectional study. Three-dimensional facial images were taken with a 3D imaging system. Subsequently, the upper eyelid region selection and areal and volumetric measurements were conducted using a modified landmarks localization strategy to evaluate their intrarater, interrater, and intramethod reliability. RESULTS: Areal measurement of the upper eyelid revealed highly reliable outcomes for intraclass correlation coefficient (ICC), mean absolute difference (MAD), relative error measurement (REM), technical error of measurement (TEM), and relative technical error of measurement (%TEM) of 0.982, 0.1620 cm(2), 2.9%, 0.1510 cm(2), and 2.7% for intrarater reliability, respectively; 0.969, 0.2076 cm(2), 3.7%, 0.1930 cm(2), and 3.5% for interrater reliability, respectively; and 0.917, 0.3636 cm(2), 6.5%, 0.3354 cm(2), and 6.0% for intramethod reliability, respectively. Unsatisfactory results were found for the volumetric measurement of the upper eyelid: the ICC, MAD, REM, TEM, and %TEM estimates for intrarater reliability were 0.992, 0.2299 mL, 10.3%, 0.2414 mL, and 10.8%, respectively; for interrater reliability, these values were 0.985, 0.2749 mL, 12.3%, 0.3253 mL, and 14.6%, respectively; and for intramethod reliability, these values were 0.433, 1.6716 mL, 77.9%, 2.0615 mL, and 96.1%, respectively. CONCLUSIONS: This is the first study to propose a standardized upper eyelid region selection strategy and simultaneously validate its reliability for 3D areal and volumetric measurements. This study confirmed the high-level reliability of areal measurement and poor reliability of volumetric measurement based on direct measurements using a single image, which may provide better results when this method is combined with the image overlapping and registration procedure. However, this is subject to further validation. Nonetheless, this method could provide quantitative areal and volumetric data on the upper eyelids and might have widespread application potential in the future. AME Publishing Company 2023-02-10 2023-03-01 /pmc/articles/PMC10006124/ /pubmed/36915328 http://dx.doi.org/10.21037/qims-22-589 Text en 2023 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Guo, Yongwei
Rokohl, Alexander C.
Fan, Wanlin
Theodosiou, Rodothea
Li, Xueting
Lou, Lixia
Gao, Tao
Lin, Ming
Yao, Ke
Heindl, Ludwig M.
A novel standardized approach for the 3D evaluation of upper eyelid area and volume
title A novel standardized approach for the 3D evaluation of upper eyelid area and volume
title_full A novel standardized approach for the 3D evaluation of upper eyelid area and volume
title_fullStr A novel standardized approach for the 3D evaluation of upper eyelid area and volume
title_full_unstemmed A novel standardized approach for the 3D evaluation of upper eyelid area and volume
title_short A novel standardized approach for the 3D evaluation of upper eyelid area and volume
title_sort novel standardized approach for the 3d evaluation of upper eyelid area and volume
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006124/
https://www.ncbi.nlm.nih.gov/pubmed/36915328
http://dx.doi.org/10.21037/qims-22-589
work_keys_str_mv AT guoyongwei anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT rokohlalexanderc anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT fanwanlin anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT theodosiourodothea anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT lixueting anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT loulixia anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT gaotao anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT linming anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT yaoke anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT heindlludwigm anovelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT guoyongwei novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT rokohlalexanderc novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT fanwanlin novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT theodosiourodothea novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT lixueting novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT loulixia novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT gaotao novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT linming novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT yaoke novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume
AT heindlludwigm novelstandardizedapproachforthe3devaluationofuppereyelidareaandvolume