Cargando…
Voxel-S-Value based 3D treatment planning methods for Y-90 microspheres radioembolization based on Tc-99m-macroaggregated albumin SPECT/CT
Partition model (PM) for Y-90 microsphere radioembolization is limited in providing 3D dosimetrics. Voxel-S-Values (VSV) method has good agreement with Monte Carlo (MC) simulations for 3D absorbed dose conversion. We propose a new VSV method and compare its performance along with PM, MC and other VS...
Autores principales: | Chen, Gefei, Lu, Zhonglin, Jiang, Han, Lin, Ko-Han, Mok, Greta S. P. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006243/ https://www.ncbi.nlm.nih.gov/pubmed/36899031 http://dx.doi.org/10.1038/s41598-023-30824-4 |
Ejemplares similares
-
Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization
por: Kao, Yung Hsiang, et al.
Publicado: (2014) -
Correlation of C-arm CT acquired parenchymal blood volume (PBV) with (99m)Tc-macroaggregated albumin (MAA) SPECT/CT for radioembolization work-up
por: Weissinger, Matthias, et al.
Publicado: (2020) -
The superior predictive value of (166)Ho-scout compared with (99m)Tc-macroaggregated albumin prior to (166)Ho-microspheres radioembolization in patients with liver metastases
por: Smits, Maarten L. J., et al.
Publicado: (2019) -
Clinical impact of (99m)Tc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with (90)Y-loaded microspheres
por: Garin, Etienne, et al.
Publicado: (2015) -
Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates
por: Barentsz, M. W., et al.
Publicado: (2010)