Cargando…
Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a met...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006963/ https://www.ncbi.nlm.nih.gov/pubmed/36904593 http://dx.doi.org/10.3390/s23052391 |
_version_ | 1784905400941805568 |
---|---|
author | Yan, Peiwu Zhang, Wenbin Yang, Le Zhang, Wenying Yu, Hao Huang, Rujin Zhu, Junyu Liu, Xi |
author_facet | Yan, Peiwu Zhang, Wenbin Yang, Le Zhang, Wenying Yu, Hao Huang, Rujin Zhu, Junyu Liu, Xi |
author_sort | Yan, Peiwu |
collection | PubMed |
description | Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices. |
format | Online Article Text |
id | pubmed-10006963 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100069632023-03-12 Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables Yan, Peiwu Zhang, Wenbin Yang, Le Zhang, Wenying Yu, Hao Huang, Rujin Zhu, Junyu Liu, Xi Sensors (Basel) Article Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices. MDPI 2023-02-21 /pmc/articles/PMC10006963/ /pubmed/36904593 http://dx.doi.org/10.3390/s23052391 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yan, Peiwu Zhang, Wenbin Yang, Le Zhang, Wenying Yu, Hao Huang, Rujin Zhu, Junyu Liu, Xi Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables |
title | Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables |
title_full | Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables |
title_fullStr | Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables |
title_full_unstemmed | Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables |
title_short | Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables |
title_sort | online calibration study of non-contact current sensors for three-phase four-wire power cables |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006963/ https://www.ncbi.nlm.nih.gov/pubmed/36904593 http://dx.doi.org/10.3390/s23052391 |
work_keys_str_mv | AT yanpeiwu onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables AT zhangwenbin onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables AT yangle onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables AT zhangwenying onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables AT yuhao onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables AT huangrujin onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables AT zhujunyu onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables AT liuxi onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables |