Cargando…

Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables

Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a met...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Peiwu, Zhang, Wenbin, Yang, Le, Zhang, Wenying, Yu, Hao, Huang, Rujin, Zhu, Junyu, Liu, Xi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006963/
https://www.ncbi.nlm.nih.gov/pubmed/36904593
http://dx.doi.org/10.3390/s23052391
_version_ 1784905400941805568
author Yan, Peiwu
Zhang, Wenbin
Yang, Le
Zhang, Wenying
Yu, Hao
Huang, Rujin
Zhu, Junyu
Liu, Xi
author_facet Yan, Peiwu
Zhang, Wenbin
Yang, Le
Zhang, Wenying
Yu, Hao
Huang, Rujin
Zhu, Junyu
Liu, Xi
author_sort Yan, Peiwu
collection PubMed
description Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices.
format Online
Article
Text
id pubmed-10006963
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100069632023-03-12 Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables Yan, Peiwu Zhang, Wenbin Yang, Le Zhang, Wenying Yu, Hao Huang, Rujin Zhu, Junyu Liu, Xi Sensors (Basel) Article Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices. MDPI 2023-02-21 /pmc/articles/PMC10006963/ /pubmed/36904593 http://dx.doi.org/10.3390/s23052391 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yan, Peiwu
Zhang, Wenbin
Yang, Le
Zhang, Wenying
Yu, Hao
Huang, Rujin
Zhu, Junyu
Liu, Xi
Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
title Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
title_full Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
title_fullStr Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
title_full_unstemmed Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
title_short Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
title_sort online calibration study of non-contact current sensors for three-phase four-wire power cables
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006963/
https://www.ncbi.nlm.nih.gov/pubmed/36904593
http://dx.doi.org/10.3390/s23052391
work_keys_str_mv AT yanpeiwu onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables
AT zhangwenbin onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables
AT yangle onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables
AT zhangwenying onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables
AT yuhao onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables
AT huangrujin onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables
AT zhujunyu onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables
AT liuxi onlinecalibrationstudyofnoncontactcurrentsensorsforthreephasefourwirepowercables