Cargando…

Calibration Methods for Time-to-Digital Converters †

In this paper, two of the most common calibration methods of synchronous TDCs, which are the bin-by-bin calibration and the average-bin-width calibration, are first presented and compared. Then, an innovative new robust calibration method for asynchronous TDCs is proposed and evaluated. Simulation r...

Descripción completa

Detalles Bibliográficos
Autores principales: Khaddour, Wassim, Uhring, Wilfried, Dadouche, Foudil, Dumas, Norbert, Madec, Morgan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007395/
https://www.ncbi.nlm.nih.gov/pubmed/36904992
http://dx.doi.org/10.3390/s23052791
_version_ 1784905510778044416
author Khaddour, Wassim
Uhring, Wilfried
Dadouche, Foudil
Dumas, Norbert
Madec, Morgan
author_facet Khaddour, Wassim
Uhring, Wilfried
Dadouche, Foudil
Dumas, Norbert
Madec, Morgan
author_sort Khaddour, Wassim
collection PubMed
description In this paper, two of the most common calibration methods of synchronous TDCs, which are the bin-by-bin calibration and the average-bin-width calibration, are first presented and compared. Then, an innovative new robust calibration method for asynchronous TDCs is proposed and evaluated. Simulation results showed that: (i) For a synchronous TDC, the bin-by-bin calibration, applied to a histogram, does not improve the TDC’s differential non-linearity (DNL); nevertheless, it improves its Integral Non-Linearity (INL), whereas the average-bin-width calibration significantly improves both the DNL and the INL. (ii) For an asynchronous TDC, the DNL can be improved up to 10 times by applying the bin–by-bin calibration, whereas the proposed method is almost independent of the non-linearity of the TDC and can improve the DNL up to 100 times. The simulation results were confirmed by experiments carried out using real TDCs implemented on a Cyclone V SoC-FPGA. For an asynchronous TDC, the proposed calibration method is 10 times better than the bin-by-bin method in terms of the DNL improvement.
format Online
Article
Text
id pubmed-10007395
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100073952023-03-12 Calibration Methods for Time-to-Digital Converters † Khaddour, Wassim Uhring, Wilfried Dadouche, Foudil Dumas, Norbert Madec, Morgan Sensors (Basel) Article In this paper, two of the most common calibration methods of synchronous TDCs, which are the bin-by-bin calibration and the average-bin-width calibration, are first presented and compared. Then, an innovative new robust calibration method for asynchronous TDCs is proposed and evaluated. Simulation results showed that: (i) For a synchronous TDC, the bin-by-bin calibration, applied to a histogram, does not improve the TDC’s differential non-linearity (DNL); nevertheless, it improves its Integral Non-Linearity (INL), whereas the average-bin-width calibration significantly improves both the DNL and the INL. (ii) For an asynchronous TDC, the DNL can be improved up to 10 times by applying the bin–by-bin calibration, whereas the proposed method is almost independent of the non-linearity of the TDC and can improve the DNL up to 100 times. The simulation results were confirmed by experiments carried out using real TDCs implemented on a Cyclone V SoC-FPGA. For an asynchronous TDC, the proposed calibration method is 10 times better than the bin-by-bin method in terms of the DNL improvement. MDPI 2023-03-03 /pmc/articles/PMC10007395/ /pubmed/36904992 http://dx.doi.org/10.3390/s23052791 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Khaddour, Wassim
Uhring, Wilfried
Dadouche, Foudil
Dumas, Norbert
Madec, Morgan
Calibration Methods for Time-to-Digital Converters †
title Calibration Methods for Time-to-Digital Converters †
title_full Calibration Methods for Time-to-Digital Converters †
title_fullStr Calibration Methods for Time-to-Digital Converters †
title_full_unstemmed Calibration Methods for Time-to-Digital Converters †
title_short Calibration Methods for Time-to-Digital Converters †
title_sort calibration methods for time-to-digital converters †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007395/
https://www.ncbi.nlm.nih.gov/pubmed/36904992
http://dx.doi.org/10.3390/s23052791
work_keys_str_mv AT khaddourwassim calibrationmethodsfortimetodigitalconverters
AT uhringwilfried calibrationmethodsfortimetodigitalconverters
AT dadouchefoudil calibrationmethodsfortimetodigitalconverters
AT dumasnorbert calibrationmethodsfortimetodigitalconverters
AT madecmorgan calibrationmethodsfortimetodigitalconverters