Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study

Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Zande, Joske, Strik, Marc, Dubois, Rémi, Ploux, Sylvain, Alrub, Saer Abu, Caillol, Théo, Nasarre, Mathieu, Donker, Dirk W., Oppersma, Eline, Bordachar, Pierre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007514/
https://www.ncbi.nlm.nih.gov/pubmed/36904759
http://dx.doi.org/10.3390/s23052555
_version_ 1784905540439113728
author van der Zande, Joske
Strik, Marc
Dubois, Rémi
Ploux, Sylvain
Alrub, Saer Abu
Caillol, Théo
Nasarre, Mathieu
Donker, Dirk W.
Oppersma, Eline
Bordachar, Pierre
author_facet van der Zande, Joske
Strik, Marc
Dubois, Rémi
Ploux, Sylvain
Alrub, Saer Abu
Caillol, Théo
Nasarre, Mathieu
Donker, Dirk W.
Oppersma, Eline
Bordachar, Pierre
author_sort van der Zande, Joske
collection PubMed
description Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain conventional frontal and precordial leads as compared to standard 12-lead ECGs in both subjects without known cardiac anomalies and patients with underlying heart disease. In 200 subjects (67% with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST, and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland–Altman analysis, including the bias, absolute offset, and 95% limits of agreement. AW-ECGs recorded on the wrist but also beyond the wrist had similar durations and amplitudes compared to standard 12-lead ECGs. Significantly greater amplitudes were measured by the AW for R-waves in precordial leads V1, V3, and V6 (+0.094 mV, +0.149 mV, +0.129 mV, respectively, all p < 0.001), indicating a positive bias for the AW. AW can be used to record frontal, and precordial ECG leads, paving the way for broader clinical applications.
format Online
Article
Text
id pubmed-10007514
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100075142023-03-12 Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study van der Zande, Joske Strik, Marc Dubois, Rémi Ploux, Sylvain Alrub, Saer Abu Caillol, Théo Nasarre, Mathieu Donker, Dirk W. Oppersma, Eline Bordachar, Pierre Sensors (Basel) Article Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain conventional frontal and precordial leads as compared to standard 12-lead ECGs in both subjects without known cardiac anomalies and patients with underlying heart disease. In 200 subjects (67% with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST, and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland–Altman analysis, including the bias, absolute offset, and 95% limits of agreement. AW-ECGs recorded on the wrist but also beyond the wrist had similar durations and amplitudes compared to standard 12-lead ECGs. Significantly greater amplitudes were measured by the AW for R-waves in precordial leads V1, V3, and V6 (+0.094 mV, +0.149 mV, +0.129 mV, respectively, all p < 0.001), indicating a positive bias for the AW. AW can be used to record frontal, and precordial ECG leads, paving the way for broader clinical applications. MDPI 2023-02-25 /pmc/articles/PMC10007514/ /pubmed/36904759 http://dx.doi.org/10.3390/s23052555 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
van der Zande, Joske
Strik, Marc
Dubois, Rémi
Ploux, Sylvain
Alrub, Saer Abu
Caillol, Théo
Nasarre, Mathieu
Donker, Dirk W.
Oppersma, Eline
Bordachar, Pierre
Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study
title Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study
title_full Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study
title_fullStr Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study
title_full_unstemmed Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study
title_short Using a Smartwatch to Record Precordial Electrocardiograms: A Validation Study
title_sort using a smartwatch to record precordial electrocardiograms: a validation study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007514/
https://www.ncbi.nlm.nih.gov/pubmed/36904759
http://dx.doi.org/10.3390/s23052555
work_keys_str_mv AT vanderzandejoske usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT strikmarc usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT duboisremi usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT plouxsylvain usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT alrubsaerabu usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT cailloltheo usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT nasarremathieu usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT donkerdirkw usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT oppersmaeline usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT bordacharpierre usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy