Cargando…

3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver

An active electrode (AE) and back-end (BE) integrated system for enhanced electrocardiogram (ECG)/electrode-tissue impedance (ETI) measurement is proposed. The AE consists of a balanced current driver and a preamplifier. To increase the output impedance, the current driver uses a matched current sou...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Xuan Tien, Ali, Muhammad, Lee, Jong-Wook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007594/
https://www.ncbi.nlm.nih.gov/pubmed/36904738
http://dx.doi.org/10.3390/s23052536
_version_ 1784905561235521536
author Nguyen, Xuan Tien
Ali, Muhammad
Lee, Jong-Wook
author_facet Nguyen, Xuan Tien
Ali, Muhammad
Lee, Jong-Wook
author_sort Nguyen, Xuan Tien
collection PubMed
description An active electrode (AE) and back-end (BE) integrated system for enhanced electrocardiogram (ECG)/electrode-tissue impedance (ETI) measurement is proposed. The AE consists of a balanced current driver and a preamplifier. To increase the output impedance, the current driver uses a matched current source and sink, which operates under negative feedback. To increase the linear input range, a new source degeneration method is proposed. The preamplifier is realized using a capacitively-coupled instrumentation amplifier (CCIA) with a ripple-reduction loop (RRL). Compared to the traditional Miller compensation, active frequency feedback compensation (AFFC) achieves bandwidth extension using the reduced size of the compensation capacitor. The BE performs three types of signal sensing: ECG, band power (BP), and impedance (IMP) data. The BP channel is used to detect the Q-, R-, and S-wave (QRS) complex in the ECG signal. The IMP channel measures the resistance and reactance of the electrode-tissue. The integrated circuits for the ECG/ETI system are realized in the 180 nm CMOS process and occupy a 1.26 mm(2) area. The measured results show that the current driver supplies a relatively high current (>600 μA(pp)) and achieves a high output impedance (1 MΩ at 500 kHz). The ETI system can detect resistance and capacitance in the ranges of 10 mΩ–3 kΩ and 100 nF–100 μF, respectively. The ECG/ETI system consumes 3.6 mW using a single 1.8 V supply.
format Online
Article
Text
id pubmed-10007594
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100075942023-03-12 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver Nguyen, Xuan Tien Ali, Muhammad Lee, Jong-Wook Sensors (Basel) Article An active electrode (AE) and back-end (BE) integrated system for enhanced electrocardiogram (ECG)/electrode-tissue impedance (ETI) measurement is proposed. The AE consists of a balanced current driver and a preamplifier. To increase the output impedance, the current driver uses a matched current source and sink, which operates under negative feedback. To increase the linear input range, a new source degeneration method is proposed. The preamplifier is realized using a capacitively-coupled instrumentation amplifier (CCIA) with a ripple-reduction loop (RRL). Compared to the traditional Miller compensation, active frequency feedback compensation (AFFC) achieves bandwidth extension using the reduced size of the compensation capacitor. The BE performs three types of signal sensing: ECG, band power (BP), and impedance (IMP) data. The BP channel is used to detect the Q-, R-, and S-wave (QRS) complex in the ECG signal. The IMP channel measures the resistance and reactance of the electrode-tissue. The integrated circuits for the ECG/ETI system are realized in the 180 nm CMOS process and occupy a 1.26 mm(2) area. The measured results show that the current driver supplies a relatively high current (>600 μA(pp)) and achieves a high output impedance (1 MΩ at 500 kHz). The ETI system can detect resistance and capacitance in the ranges of 10 mΩ–3 kΩ and 100 nF–100 μF, respectively. The ECG/ETI system consumes 3.6 mW using a single 1.8 V supply. MDPI 2023-02-24 /pmc/articles/PMC10007594/ /pubmed/36904738 http://dx.doi.org/10.3390/s23052536 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nguyen, Xuan Tien
Ali, Muhammad
Lee, Jong-Wook
3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_full 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_fullStr 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_full_unstemmed 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_short 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_sort 3.6 mw active-electrode ecg/eti sensor system using wideband low-noise instrumentation amplifier and high impedance balanced current driver
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007594/
https://www.ncbi.nlm.nih.gov/pubmed/36904738
http://dx.doi.org/10.3390/s23052536
work_keys_str_mv AT nguyenxuantien 36mwactiveelectrodeecgetisensorsystemusingwidebandlownoiseinstrumentationamplifierandhighimpedancebalancedcurrentdriver
AT alimuhammad 36mwactiveelectrodeecgetisensorsystemusingwidebandlownoiseinstrumentationamplifierandhighimpedancebalancedcurrentdriver
AT leejongwook 36mwactiveelectrodeecgetisensorsystemusingwidebandlownoiseinstrumentationamplifierandhighimpedancebalancedcurrentdriver