Cargando…

DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring

A sudden cardiac event in patients with heart disease can lead to a heart attack in extreme cases. Therefore, prompt interventions for the particular heart situation and periodic monitoring are critical. This study focuses on a heart sound analysis method that can be monitored daily using multimodal...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Miran, Wei, Qun, Lee, Soomin, Park, Heejoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007616/
https://www.ncbi.nlm.nih.gov/pubmed/36904628
http://dx.doi.org/10.3390/s23052423
_version_ 1784905566829674496
author Lee, Miran
Wei, Qun
Lee, Soomin
Park, Heejoon
author_facet Lee, Miran
Wei, Qun
Lee, Soomin
Park, Heejoon
author_sort Lee, Miran
collection PubMed
description A sudden cardiac event in patients with heart disease can lead to a heart attack in extreme cases. Therefore, prompt interventions for the particular heart situation and periodic monitoring are critical. This study focuses on a heart sound analysis method that can be monitored daily using multimodal signals acquired with wearable devices. The dual deterministic model-based heart sound analysis is designed in a parallel structure that uses two bio-signals (PCG and PPG signals) related to the heartbeat, enabling more accurate heart sound identification. The experimental results show promising performance of the proposed Model III (DDM-HSA with window and envelope filter), which had the highest performance, and S1 and S2 showed average accuracy (unit: %) of 95.39 (±2.14) and 92.55 (±3.74), respectively. The findings of this study are anticipated to provide improved technology to detect heart sounds and analyze cardiac activities using only bio-signals that can be measured using wearable devices in a mobile environment.
format Online
Article
Text
id pubmed-10007616
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100076162023-03-12 DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring Lee, Miran Wei, Qun Lee, Soomin Park, Heejoon Sensors (Basel) Article A sudden cardiac event in patients with heart disease can lead to a heart attack in extreme cases. Therefore, prompt interventions for the particular heart situation and periodic monitoring are critical. This study focuses on a heart sound analysis method that can be monitored daily using multimodal signals acquired with wearable devices. The dual deterministic model-based heart sound analysis is designed in a parallel structure that uses two bio-signals (PCG and PPG signals) related to the heartbeat, enabling more accurate heart sound identification. The experimental results show promising performance of the proposed Model III (DDM-HSA with window and envelope filter), which had the highest performance, and S1 and S2 showed average accuracy (unit: %) of 95.39 (±2.14) and 92.55 (±3.74), respectively. The findings of this study are anticipated to provide improved technology to detect heart sounds and analyze cardiac activities using only bio-signals that can be measured using wearable devices in a mobile environment. MDPI 2023-02-22 /pmc/articles/PMC10007616/ /pubmed/36904628 http://dx.doi.org/10.3390/s23052423 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Miran
Wei, Qun
Lee, Soomin
Park, Heejoon
DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring
title DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring
title_full DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring
title_fullStr DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring
title_full_unstemmed DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring
title_short DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring
title_sort ddm-hsa: dual deterministic model-based heart sound analysis for daily life monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007616/
https://www.ncbi.nlm.nih.gov/pubmed/36904628
http://dx.doi.org/10.3390/s23052423
work_keys_str_mv AT leemiran ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring
AT weiqun ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring
AT leesoomin ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring
AT parkheejoon ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring