DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring
A sudden cardiac event in patients with heart disease can lead to a heart attack in extreme cases. Therefore, prompt interventions for the particular heart situation and periodic monitoring are critical. This study focuses on a heart sound analysis method that can be monitored daily using multimodal...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007616/ https://www.ncbi.nlm.nih.gov/pubmed/36904628 http://dx.doi.org/10.3390/s23052423 |
_version_ | 1784905566829674496 |
---|---|
author | Lee, Miran Wei, Qun Lee, Soomin Park, Heejoon |
author_facet | Lee, Miran Wei, Qun Lee, Soomin Park, Heejoon |
author_sort | Lee, Miran |
collection | PubMed |
description | A sudden cardiac event in patients with heart disease can lead to a heart attack in extreme cases. Therefore, prompt interventions for the particular heart situation and periodic monitoring are critical. This study focuses on a heart sound analysis method that can be monitored daily using multimodal signals acquired with wearable devices. The dual deterministic model-based heart sound analysis is designed in a parallel structure that uses two bio-signals (PCG and PPG signals) related to the heartbeat, enabling more accurate heart sound identification. The experimental results show promising performance of the proposed Model III (DDM-HSA with window and envelope filter), which had the highest performance, and S1 and S2 showed average accuracy (unit: %) of 95.39 (±2.14) and 92.55 (±3.74), respectively. The findings of this study are anticipated to provide improved technology to detect heart sounds and analyze cardiac activities using only bio-signals that can be measured using wearable devices in a mobile environment. |
format | Online Article Text |
id | pubmed-10007616 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100076162023-03-12 DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring Lee, Miran Wei, Qun Lee, Soomin Park, Heejoon Sensors (Basel) Article A sudden cardiac event in patients with heart disease can lead to a heart attack in extreme cases. Therefore, prompt interventions for the particular heart situation and periodic monitoring are critical. This study focuses on a heart sound analysis method that can be monitored daily using multimodal signals acquired with wearable devices. The dual deterministic model-based heart sound analysis is designed in a parallel structure that uses two bio-signals (PCG and PPG signals) related to the heartbeat, enabling more accurate heart sound identification. The experimental results show promising performance of the proposed Model III (DDM-HSA with window and envelope filter), which had the highest performance, and S1 and S2 showed average accuracy (unit: %) of 95.39 (±2.14) and 92.55 (±3.74), respectively. The findings of this study are anticipated to provide improved technology to detect heart sounds and analyze cardiac activities using only bio-signals that can be measured using wearable devices in a mobile environment. MDPI 2023-02-22 /pmc/articles/PMC10007616/ /pubmed/36904628 http://dx.doi.org/10.3390/s23052423 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Miran Wei, Qun Lee, Soomin Park, Heejoon DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring |
title | DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring |
title_full | DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring |
title_fullStr | DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring |
title_full_unstemmed | DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring |
title_short | DDM-HSA: Dual Deterministic Model-Based Heart Sound Analysis for Daily Life Monitoring |
title_sort | ddm-hsa: dual deterministic model-based heart sound analysis for daily life monitoring |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10007616/ https://www.ncbi.nlm.nih.gov/pubmed/36904628 http://dx.doi.org/10.3390/s23052423 |
work_keys_str_mv | AT leemiran ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring AT weiqun ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring AT leesoomin ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring AT parkheejoon ddmhsadualdeterministicmodelbasedheartsoundanalysisfordailylifemonitoring |