Evaluation of NPP Efficiency Using Phase-Transition Batteries

In the context of the growing share of nuclear power plants in the energy systems of the European part of Russia and the shortage of flexible generating capacities, it becomes necessary to involve nuclear power plants in covering the variable part of the load schedule. With relatively low prices for...

Descripción completa

Detalles Bibliográficos
Autores principales: Aminov, R. Z., Garievsky, M. V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Pleiades Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10008204/
http://dx.doi.org/10.1134/S0040601523020015
_version_ 1784905705877143552
author Aminov, R. Z.
Garievsky, M. V.
author_facet Aminov, R. Z.
Garievsky, M. V.
author_sort Aminov, R. Z.
collection PubMed
description In the context of the growing share of nuclear power plants in the energy systems of the European part of Russia and the shortage of flexible generating capacities, it becomes necessary to involve nuclear power plants in covering the variable part of the load schedule. With relatively low prices for nuclear fuel (at present, the equivalent cost of a uranium fuel load is five to six times lower than the cost of natural gas inside the country) and high specific capital investments in nuclear power plants, it is not economically efficient to unload them. Therefore, the combination of nuclear power plants with latent heat thermal energy storage (LHTES) and an additional steam turbine makes it possible to accumulate thermal energy generated at night and use it during peak hours to generate electricity with the maximum use of nuclear fuel, i.e., without changing the power of the nuclear reactor. In addition, the presence of an additional turbogenerator in emergency situations with a complete blackout of the NPP makes it possible to ensure the operation of the cooling systems by using the residual heat of the reactor to drive the turbine and, thereby, increase the safety level of the NPP. The analysis of prices for electricity in the wholesale electricity and capacity market of the Unified Energy System of Russia (WECM UES) and in the energy system of France (with the highest share of nuclear power plants) was carried out. The impact of the operation of the NPP power unit with a thermal energy storage system was assessed in addition to the alternative option: the construction of a pumped storage power plant (PSPP) at the WECM. Calculations of technical and economic indicators of the use of LHTES-based thermal energy accumulators at NPPs are carried out depending on the level of thermal power of the latter as well as the increase in the regulation range for electricity supply. It is shown that if we do not take into account the multifunctional properties of the energy complex based on LHTES and an additional turbine (increased safety, NPP participation in primary frequency control) with the existing difference in prices for electricity generated during peak and night periods on the day-ahead market, the payback of the NPP energy complex for LHTES-based is not provided. The return on investment in phase-change batteries and an additional turbine in the considered example can be achieved provided that the difference between the average prices for electricity generated during peak and night hours over a billing period of 25 years is 3400 rubles/(MW h) and the charging time/LHTES discharge exceeds 7 h per day.
format Online
Article
Text
id pubmed-10008204
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Pleiades Publishing
record_format MEDLINE/PubMed
spelling pubmed-100082042023-03-13 Evaluation of NPP Efficiency Using Phase-Transition Batteries Aminov, R. Z. Garievsky, M. V. Therm. Eng. Nuclear Power Plants In the context of the growing share of nuclear power plants in the energy systems of the European part of Russia and the shortage of flexible generating capacities, it becomes necessary to involve nuclear power plants in covering the variable part of the load schedule. With relatively low prices for nuclear fuel (at present, the equivalent cost of a uranium fuel load is five to six times lower than the cost of natural gas inside the country) and high specific capital investments in nuclear power plants, it is not economically efficient to unload them. Therefore, the combination of nuclear power plants with latent heat thermal energy storage (LHTES) and an additional steam turbine makes it possible to accumulate thermal energy generated at night and use it during peak hours to generate electricity with the maximum use of nuclear fuel, i.e., without changing the power of the nuclear reactor. In addition, the presence of an additional turbogenerator in emergency situations with a complete blackout of the NPP makes it possible to ensure the operation of the cooling systems by using the residual heat of the reactor to drive the turbine and, thereby, increase the safety level of the NPP. The analysis of prices for electricity in the wholesale electricity and capacity market of the Unified Energy System of Russia (WECM UES) and in the energy system of France (with the highest share of nuclear power plants) was carried out. The impact of the operation of the NPP power unit with a thermal energy storage system was assessed in addition to the alternative option: the construction of a pumped storage power plant (PSPP) at the WECM. Calculations of technical and economic indicators of the use of LHTES-based thermal energy accumulators at NPPs are carried out depending on the level of thermal power of the latter as well as the increase in the regulation range for electricity supply. It is shown that if we do not take into account the multifunctional properties of the energy complex based on LHTES and an additional turbine (increased safety, NPP participation in primary frequency control) with the existing difference in prices for electricity generated during peak and night periods on the day-ahead market, the payback of the NPP energy complex for LHTES-based is not provided. The return on investment in phase-change batteries and an additional turbine in the considered example can be achieved provided that the difference between the average prices for electricity generated during peak and night hours over a billing period of 25 years is 3400 rubles/(MW h) and the charging time/LHTES discharge exceeds 7 h per day. Pleiades Publishing 2023-03-12 2023 /pmc/articles/PMC10008204/ http://dx.doi.org/10.1134/S0040601523020015 Text en © Pleiades Publishing, Inc. 2023, ISSN 0040-6015, Thermal Engineering, 2023, Vol. 70, No. 2, pp. 145–155. © Pleiades Publishing, Inc., 2023.Russian Text © The Author(s), 2023, published in Teploenergetika. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Nuclear Power Plants
Aminov, R. Z.
Garievsky, M. V.
Evaluation of NPP Efficiency Using Phase-Transition Batteries
title Evaluation of NPP Efficiency Using Phase-Transition Batteries
title_full Evaluation of NPP Efficiency Using Phase-Transition Batteries
title_fullStr Evaluation of NPP Efficiency Using Phase-Transition Batteries
title_full_unstemmed Evaluation of NPP Efficiency Using Phase-Transition Batteries
title_short Evaluation of NPP Efficiency Using Phase-Transition Batteries
title_sort evaluation of npp efficiency using phase-transition batteries
topic Nuclear Power Plants
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10008204/
http://dx.doi.org/10.1134/S0040601523020015
work_keys_str_mv AT aminovrz evaluationofnppefficiencyusingphasetransitionbatteries
AT garievskymv evaluationofnppefficiencyusingphasetransitionbatteries