Cargando…

Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes

BACKGROUND: Infrared thermography devices have been commonly applied to measure superficial temperature in structural composites and walls. These tools were cheaper than other thermographic devices used to measure superficial human muscle tissue temperature. In addition, infrared thermography has be...

Descripción completa

Detalles Bibliográficos
Autores principales: Calvo-Lobo, Cesar, San-Antolín, Marta, García-García, Daniel, Becerro-de-Bengoa-Vallejo, Ricardo, Losa-Iglesias, Marta Elena, Cosín-Matamoros, Julia, Casado-Hernández, Israel, Martínez-Jiménez, Eva María, Mazoteras-Pardo, Victoria, Rodríguez-Sanz, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10008311/
https://www.ncbi.nlm.nih.gov/pubmed/36919164
http://dx.doi.org/10.7717/peerj.15011
_version_ 1784905729279262720
author Calvo-Lobo, Cesar
San-Antolín, Marta
García-García, Daniel
Becerro-de-Bengoa-Vallejo, Ricardo
Losa-Iglesias, Marta Elena
Cosín-Matamoros, Julia
Casado-Hernández, Israel
Martínez-Jiménez, Eva María
Mazoteras-Pardo, Victoria
Rodríguez-Sanz, David
author_facet Calvo-Lobo, Cesar
San-Antolín, Marta
García-García, Daniel
Becerro-de-Bengoa-Vallejo, Ricardo
Losa-Iglesias, Marta Elena
Cosín-Matamoros, Julia
Casado-Hernández, Israel
Martínez-Jiménez, Eva María
Mazoteras-Pardo, Victoria
Rodríguez-Sanz, David
author_sort Calvo-Lobo, Cesar
collection PubMed
description BACKGROUND: Infrared thermography devices have been commonly applied to measure superficial temperature in structural composites and walls. These tools were cheaper than other thermographic devices used to measure superficial human muscle tissue temperature. In addition, infrared thermography has been previously used to assess skin temperature related to muscle tissue conditions in the triceps surae of athletes. Nevertheless, the reliability and repeatability of an infrared thermography device designed for materials, such as the Manual Infrared Camera PCE-TC 30, have yet to be determined to measure skin temperature of the triceps surae muscle tissue of athletes. OBJECTIVE: The purpose was to determine the procedure’s intra- and inter-session reliability and repeatability to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device in the triceps surae muscle tissue of athletes, which was initially designed to measure the superficial temperature of materials. METHODS: A total of 34 triceps surae muscles were bilaterally assessed from 17 healthy athletes using the Manual Infrared Camera PCE-TC 30 thermography device to determine intra- (at the same day separated by 1 h) and inter-session (at alternate days separated by 48 h) reliability and repeatability of the skin temperature of the soleus, medial and lateral gastrocnemius muscles. The triceps surae complex weas measured by a region of interest of 1 cm(2) through five infrared thermography images for each muscle. Statistical analyses comprised intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimum detectable change (MCD), systematic error of measurement, correlation (r), and Bland-Altman plots completed with linear regression models (R(2)). RESULTS: Intra- and inter-session measurements of the proposed infrared thermography procedure showed excellent reliability (ICC((1,2)) = 0.968–0.977), measurement errors (SEM = 0.186–0.232 °C; MDC = 0.515–0.643 °C), correlations (r = 0.885–0.953), and did not present significant systematic error of measurements (P > 0.05). Adequate agreement between each pair of measurement moments was presented by the Bland-Altman plots according to the limits of agreement and non-significant linear regression models (R(2) = 0.000–0.019; P > 0.05). CONCLUSIONS: The proposed procedure to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device presented excellent intra- and inter-session reliability and repeatability in athletes’ triceps surae muscle tissue. Future studies should consider the SEM and MDC of this procedure to measure the skin temperature of soleus, medial, and lateral gastrocnemius muscles to promote triceps surae muscle prevention and recovery in athletes.
format Online
Article
Text
id pubmed-10008311
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-100083112023-03-13 Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes Calvo-Lobo, Cesar San-Antolín, Marta García-García, Daniel Becerro-de-Bengoa-Vallejo, Ricardo Losa-Iglesias, Marta Elena Cosín-Matamoros, Julia Casado-Hernández, Israel Martínez-Jiménez, Eva María Mazoteras-Pardo, Victoria Rodríguez-Sanz, David PeerJ Anatomy and Physiology BACKGROUND: Infrared thermography devices have been commonly applied to measure superficial temperature in structural composites and walls. These tools were cheaper than other thermographic devices used to measure superficial human muscle tissue temperature. In addition, infrared thermography has been previously used to assess skin temperature related to muscle tissue conditions in the triceps surae of athletes. Nevertheless, the reliability and repeatability of an infrared thermography device designed for materials, such as the Manual Infrared Camera PCE-TC 30, have yet to be determined to measure skin temperature of the triceps surae muscle tissue of athletes. OBJECTIVE: The purpose was to determine the procedure’s intra- and inter-session reliability and repeatability to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device in the triceps surae muscle tissue of athletes, which was initially designed to measure the superficial temperature of materials. METHODS: A total of 34 triceps surae muscles were bilaterally assessed from 17 healthy athletes using the Manual Infrared Camera PCE-TC 30 thermography device to determine intra- (at the same day separated by 1 h) and inter-session (at alternate days separated by 48 h) reliability and repeatability of the skin temperature of the soleus, medial and lateral gastrocnemius muscles. The triceps surae complex weas measured by a region of interest of 1 cm(2) through five infrared thermography images for each muscle. Statistical analyses comprised intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimum detectable change (MCD), systematic error of measurement, correlation (r), and Bland-Altman plots completed with linear regression models (R(2)). RESULTS: Intra- and inter-session measurements of the proposed infrared thermography procedure showed excellent reliability (ICC((1,2)) = 0.968–0.977), measurement errors (SEM = 0.186–0.232 °C; MDC = 0.515–0.643 °C), correlations (r = 0.885–0.953), and did not present significant systematic error of measurements (P > 0.05). Adequate agreement between each pair of measurement moments was presented by the Bland-Altman plots according to the limits of agreement and non-significant linear regression models (R(2) = 0.000–0.019; P > 0.05). CONCLUSIONS: The proposed procedure to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device presented excellent intra- and inter-session reliability and repeatability in athletes’ triceps surae muscle tissue. Future studies should consider the SEM and MDC of this procedure to measure the skin temperature of soleus, medial, and lateral gastrocnemius muscles to promote triceps surae muscle prevention and recovery in athletes. PeerJ Inc. 2023-03-09 /pmc/articles/PMC10008311/ /pubmed/36919164 http://dx.doi.org/10.7717/peerj.15011 Text en © 2023 Calvo-Lobo et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Anatomy and Physiology
Calvo-Lobo, Cesar
San-Antolín, Marta
García-García, Daniel
Becerro-de-Bengoa-Vallejo, Ricardo
Losa-Iglesias, Marta Elena
Cosín-Matamoros, Julia
Casado-Hernández, Israel
Martínez-Jiménez, Eva María
Mazoteras-Pardo, Victoria
Rodríguez-Sanz, David
Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
title Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
title_full Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
title_fullStr Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
title_full_unstemmed Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
title_short Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
title_sort intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
topic Anatomy and Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10008311/
https://www.ncbi.nlm.nih.gov/pubmed/36919164
http://dx.doi.org/10.7717/peerj.15011
work_keys_str_mv AT calvolobocesar intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT sanantolinmarta intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT garciagarciadaniel intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT becerrodebengoavallejoricardo intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT losaiglesiasmartaelena intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT cosinmatamorosjulia intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT casadohernandezisrael intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT martinezjimenezevamaria intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT mazoteraspardovictoria intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes
AT rodriguezsanzdavid intraandintersessionreliabilityandrepeatabilityofaninfraredthermographydevicedesignedformaterialstomeasureskintemperatureofthetricepssuraemuscletissueofathletes