Cargando…
Three developed spectrophotometric methods for determination of a mixture of ofloxacin and ornidazole; application of greenness assessment tools
This work is dedicated to the greenness estimation of three proposed spectrophotometric techniques [e.g., ratio difference (RD), mean centering of ratio spectra (MCR) and continuous wavelet transform of ratio spectra (CWT)] for the determination of a binary combination named Ofloxacin (OFL) and Orni...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10010042/ https://www.ncbi.nlm.nih.gov/pubmed/36915195 http://dx.doi.org/10.1186/s13065-023-00932-3 |
Sumario: | This work is dedicated to the greenness estimation of three proposed spectrophotometric techniques [e.g., ratio difference (RD), mean centering of ratio spectra (MCR) and continuous wavelet transform of ratio spectra (CWT)] for the determination of a binary combination named Ofloxacin (OFL) and Ornidazole (ORN). Applying the green analytical chemistry methods to assess the proposed methods has widely attained the analytical community care. The greenness assessment was performed via three evaluation approaches; the “Analytical Eco-Scale”, the “National Environmental Method Index” (NEMI) and “Green Analytical Procedure Index” (GAPI). Following the examination of the zero spectrum of OFL and ORN, it is observed that OFL and ORN spectra are overlapped, so they can be detected by the methods mentioned previously. The ratio difference method was carried out at wavelengths of 294.6 nm and 265.6 nm for OFL, 292 nm and 315 nm for ORN. The linear range was (2–15 µg/mL) for OFL and (3–30 µg/mL) for ORN. The MCR method based on the use of mean centered ratio spectra in dual steps and calculating the second ratio spectra mean centered values at 294.6 nm for OFL and 315 nm for ORN. The continuous wavelet transformation which carried out using MATLAB at wavelengths of 265 nm for OFL and 306 for ORN. These techniques were intended for the binary mixture analysis in bulk powder and pharmaceutical formulations with high recoveries. The developed methods were validated according to ICH guidelines. All techniques were statistically compared to either an official method for OFL or a reported method for ORN and the results indicate that there were not any significant differences. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13065-023-00932-3. |
---|