Cargando…
Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography
PURPOSE: To develop a semi-automated method of measuring foveal maturity using investigational handheld swept source-optical coherence tomography (SS-OCT). METHODS: In this prospective, observational study, full-term newborns and preterm infants undergoing routine retinopathy of prematurity screenin...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10010441/ https://www.ncbi.nlm.nih.gov/pubmed/36881403 http://dx.doi.org/10.1167/tvst.12.3.5 |
_version_ | 1784906177744732160 |
---|---|
author | Lawson, Sumner E. Tam, Emily K. Zheng, Yujiao Liu, Teng Monger, Tatiana R. Lee, Karen E. Legocki, Alex Kelly, John Ding, Leona Wang, Ruikang K. Tarczy-Hornoch, Kristina Cabrera, Michelle T. |
author_facet | Lawson, Sumner E. Tam, Emily K. Zheng, Yujiao Liu, Teng Monger, Tatiana R. Lee, Karen E. Legocki, Alex Kelly, John Ding, Leona Wang, Ruikang K. Tarczy-Hornoch, Kristina Cabrera, Michelle T. |
author_sort | Lawson, Sumner E. |
collection | PubMed |
description | PURPOSE: To develop a semi-automated method of measuring foveal maturity using investigational handheld swept source-optical coherence tomography (SS-OCT). METHODS: In this prospective, observational study, full-term newborns and preterm infants undergoing routine retinopathy of prematurity screening were imaged. Semi-automated analysis measured foveal angle and chorioretinal thicknesses at the central fovea and average two-sided parafovea by three-grader consensus, correlating with OCT features and demographics. RESULTS: One hundred ninety-four imaging sessions from 70 infants were included (47.8% girls, 37.6 ± 3.4 weeks postmenstrual age, 26 preterm infants with birth weight 1057 ± 325.0, gestational age 29.0 ± 3.0 weeks). Foveal angle (96.1 ± 22.0 degrees) steepened with increasing birth weight (P = 0.003), decreasing inner retinal layer thickness, and increasing gestational age, postmenstrual age, and foveal and parafoveal choroidal thickness (all P < 0.001). Inner retinal fovea/parafovea ratio (0.4 ± 0.2) correlated with increasing inner foveal layers, decreasing postmenstrual age, gestational age, and birth weight (all P < 0.001). Outer retinal F/P ratio (0.7 ± 0.2) correlated with ellipsoid zone presence (P < 0.001), increased gestational age (P = 0.002), and birth weight (P = 0.003). Foveal (447.8 ± 120.6 microns) and parafoveal (420.9 ± 109.2) choroidal thicknesses correlated with foveal ellipsoid zone presence (P = 0.007 and P = 0.01, respectively), postmenstrual age, birth weight, gestational age, and decreasing inner retinal layers (all P < 0.001). CONCLUSIONS: Foveal development is dynamic and partially observed through semi-automated analysis of handheld SS-OCT imaging. TRANSLATIONAL RELEVANCE: Semi-automated analysis of SS-OCT images can identify measures of foveal maturity. |
format | Online Article Text |
id | pubmed-10010441 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-100104412023-03-14 Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography Lawson, Sumner E. Tam, Emily K. Zheng, Yujiao Liu, Teng Monger, Tatiana R. Lee, Karen E. Legocki, Alex Kelly, John Ding, Leona Wang, Ruikang K. Tarczy-Hornoch, Kristina Cabrera, Michelle T. Transl Vis Sci Technol Retina PURPOSE: To develop a semi-automated method of measuring foveal maturity using investigational handheld swept source-optical coherence tomography (SS-OCT). METHODS: In this prospective, observational study, full-term newborns and preterm infants undergoing routine retinopathy of prematurity screening were imaged. Semi-automated analysis measured foveal angle and chorioretinal thicknesses at the central fovea and average two-sided parafovea by three-grader consensus, correlating with OCT features and demographics. RESULTS: One hundred ninety-four imaging sessions from 70 infants were included (47.8% girls, 37.6 ± 3.4 weeks postmenstrual age, 26 preterm infants with birth weight 1057 ± 325.0, gestational age 29.0 ± 3.0 weeks). Foveal angle (96.1 ± 22.0 degrees) steepened with increasing birth weight (P = 0.003), decreasing inner retinal layer thickness, and increasing gestational age, postmenstrual age, and foveal and parafoveal choroidal thickness (all P < 0.001). Inner retinal fovea/parafovea ratio (0.4 ± 0.2) correlated with increasing inner foveal layers, decreasing postmenstrual age, gestational age, and birth weight (all P < 0.001). Outer retinal F/P ratio (0.7 ± 0.2) correlated with ellipsoid zone presence (P < 0.001), increased gestational age (P = 0.002), and birth weight (P = 0.003). Foveal (447.8 ± 120.6 microns) and parafoveal (420.9 ± 109.2) choroidal thicknesses correlated with foveal ellipsoid zone presence (P = 0.007 and P = 0.01, respectively), postmenstrual age, birth weight, gestational age, and decreasing inner retinal layers (all P < 0.001). CONCLUSIONS: Foveal development is dynamic and partially observed through semi-automated analysis of handheld SS-OCT imaging. TRANSLATIONAL RELEVANCE: Semi-automated analysis of SS-OCT images can identify measures of foveal maturity. The Association for Research in Vision and Ophthalmology 2023-03-07 /pmc/articles/PMC10010441/ /pubmed/36881403 http://dx.doi.org/10.1167/tvst.12.3.5 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Retina Lawson, Sumner E. Tam, Emily K. Zheng, Yujiao Liu, Teng Monger, Tatiana R. Lee, Karen E. Legocki, Alex Kelly, John Ding, Leona Wang, Ruikang K. Tarczy-Hornoch, Kristina Cabrera, Michelle T. Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography |
title | Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography |
title_full | Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography |
title_fullStr | Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography |
title_full_unstemmed | Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography |
title_short | Semi-Automated Analysis of Foveal Maturity in Premature and Full-Term Infants Using Handheld Swept-Source Optical Coherence Tomography |
title_sort | semi-automated analysis of foveal maturity in premature and full-term infants using handheld swept-source optical coherence tomography |
topic | Retina |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10010441/ https://www.ncbi.nlm.nih.gov/pubmed/36881403 http://dx.doi.org/10.1167/tvst.12.3.5 |
work_keys_str_mv | AT lawsonsumnere semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT tamemilyk semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT zhengyujiao semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT liuteng semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT mongertatianar semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT leekarene semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT legockialex semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT kellyjohn semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT dingleona semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT wangruikangk semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT tarczyhornochkristina semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography AT cabreramichellet semiautomatedanalysisoffovealmaturityinprematureandfullterminfantsusinghandheldsweptsourceopticalcoherencetomography |