Cargando…

Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes

The use of sintered-wick heat pipes in heat exchanger performance-related studies gained popularity owing to the simplicity and affordability of heat pipes. Evaluation of the system performance may be based on various arrangements and numbers of heat pipes applicable to the literature. Wick porosity...

Descripción completa

Detalles Bibliográficos
Autores principales: Agustina, Dinni, Putra, Nandy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10011195/
https://www.ncbi.nlm.nih.gov/pubmed/36925538
http://dx.doi.org/10.1016/j.heliyon.2023.e13936
_version_ 1784906336670056448
author Agustina, Dinni
Putra, Nandy
author_facet Agustina, Dinni
Putra, Nandy
author_sort Agustina, Dinni
collection PubMed
description The use of sintered-wick heat pipes in heat exchanger performance-related studies gained popularity owing to the simplicity and affordability of heat pipes. Evaluation of the system performance may be based on various arrangements and numbers of heat pipes applicable to the literature. Wick porosity and permeability are critical parameters for the investigation of wick capillary pumping, which will ultimately determine heat pipe performance. Despite the significance of these parameters to thermal performance, they are difficult to obtain, as the methods for obtaining these parameters before installing the heat pipes are time-consuming and destructive. This study aims to investigate the feasibility of Micro Tomography (Micro CT) to observe the porosity of copper sintered-wick heat pipes. Visual data from three heat pipe samples, namely HP1, HP2, and HP3 are quantified and analyzed. Analysis of the average porosity of HP1 and HP2 samples showed a similar value of 47.6 and 48.1%, respectively; however, the value of porosity along the length of the scanned area shows a bigger range of 42–54%. The accuracy of Micro CT was tested by testing three porosity samples with designed porosity of 26%, 22.3%, and 16.6% which were 3D printed using atomic diffusion additive manufacturing technology. Each sample was designed with pore shapes hexagonal, circular, and elliptical, respectively. Micro CT visualization and analysis showed the porosity reduction of the 3D printed porosity samples compared to the CAD design. Due to the smallest reduction of porosity after the sintered process, the 3D printed sample with a hexagonal pore shape, and the designed porosity of 26%, this sample was recommended for sintered wick fabrication using this technology and to test the accuracy of Micro CT.
format Online
Article
Text
id pubmed-10011195
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-100111952023-03-15 Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes Agustina, Dinni Putra, Nandy Heliyon Research Article The use of sintered-wick heat pipes in heat exchanger performance-related studies gained popularity owing to the simplicity and affordability of heat pipes. Evaluation of the system performance may be based on various arrangements and numbers of heat pipes applicable to the literature. Wick porosity and permeability are critical parameters for the investigation of wick capillary pumping, which will ultimately determine heat pipe performance. Despite the significance of these parameters to thermal performance, they are difficult to obtain, as the methods for obtaining these parameters before installing the heat pipes are time-consuming and destructive. This study aims to investigate the feasibility of Micro Tomography (Micro CT) to observe the porosity of copper sintered-wick heat pipes. Visual data from three heat pipe samples, namely HP1, HP2, and HP3 are quantified and analyzed. Analysis of the average porosity of HP1 and HP2 samples showed a similar value of 47.6 and 48.1%, respectively; however, the value of porosity along the length of the scanned area shows a bigger range of 42–54%. The accuracy of Micro CT was tested by testing three porosity samples with designed porosity of 26%, 22.3%, and 16.6% which were 3D printed using atomic diffusion additive manufacturing technology. Each sample was designed with pore shapes hexagonal, circular, and elliptical, respectively. Micro CT visualization and analysis showed the porosity reduction of the 3D printed porosity samples compared to the CAD design. Due to the smallest reduction of porosity after the sintered process, the 3D printed sample with a hexagonal pore shape, and the designed porosity of 26%, this sample was recommended for sintered wick fabrication using this technology and to test the accuracy of Micro CT. Elsevier 2023-02-24 /pmc/articles/PMC10011195/ /pubmed/36925538 http://dx.doi.org/10.1016/j.heliyon.2023.e13936 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Agustina, Dinni
Putra, Nandy
Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes
title Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes
title_full Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes
title_fullStr Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes
title_full_unstemmed Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes
title_short Investigation of Micro CT based method for porosity estimation of sintered-wick heat pipes
title_sort investigation of micro ct based method for porosity estimation of sintered-wick heat pipes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10011195/
https://www.ncbi.nlm.nih.gov/pubmed/36925538
http://dx.doi.org/10.1016/j.heliyon.2023.e13936
work_keys_str_mv AT agustinadinni investigationofmicroctbasedmethodforporosityestimationofsinteredwickheatpipes
AT putranandy investigationofmicroctbasedmethodforporosityestimationofsinteredwickheatpipes