Cargando…

Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic

OBJECTIVE: To evaluate the diagnostic performance of computed tomography (CT) fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) in pulmonary nodules ≤ 10 mm during the coronavirus disease 2019 pandemic. MATERIALS AND METHODS: Between January 1, 2020 and April 30, 2022, a total of 35...

Descripción completa

Detalles Bibliográficos
Autores principales: Nunes, Thiago Franchi, Inchingolo, Riccardo, Kikuti, Cristina Faria, de Faria, Bernardo Bacelar, Galhardo, Cezar Augusto Vendas, Tognini, João Ricardo Filgueiras, Marchiori, Edson, Hochhegger, Bruno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10013188/
https://www.ncbi.nlm.nih.gov/pubmed/36926361
http://dx.doi.org/10.1590/0100-3984.2022.0062-en
_version_ 1784906765793492992
author Nunes, Thiago Franchi
Inchingolo, Riccardo
Kikuti, Cristina Faria
de Faria, Bernardo Bacelar
Galhardo, Cezar Augusto Vendas
Tognini, João Ricardo Filgueiras
Marchiori, Edson
Hochhegger, Bruno
author_facet Nunes, Thiago Franchi
Inchingolo, Riccardo
Kikuti, Cristina Faria
de Faria, Bernardo Bacelar
Galhardo, Cezar Augusto Vendas
Tognini, João Ricardo Filgueiras
Marchiori, Edson
Hochhegger, Bruno
author_sort Nunes, Thiago Franchi
collection PubMed
description OBJECTIVE: To evaluate the diagnostic performance of computed tomography (CT) fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) in pulmonary nodules ≤ 10 mm during the coronavirus disease 2019 pandemic. MATERIALS AND METHODS: Between January 1, 2020 and April 30, 2022, a total of 359 CT fluoroscopy-guided PTNBs were performed at an interventional radiology center. Lung lesions measured between 2 mm and 108 mm. Of the 359 PTNBs, 27 (7.5%) were performed with an 18G core needle on nodules ≤ 10 mm in diameter. RESULTS: Among the 27 biopsies performed on nodules ≤ 10 mm, the lesions measured < 5 mm in four and 5-10 mm in 23. The sensitivity and overall diagnostic accuracy of PTNB were 100% and 92.3%, respectively. The mean dose of ionizing radiation during PTNB was 581.33 mGy*cm (range, 303-1,129 mGy*cm), and the mean biopsy procedure time was 6.6 min (range, 2-12 min). There were no major postprocedural complications. CONCLUSION: CT fluoroscopy-guided PTNB appears to provide a high diagnostic yield with low complication rates.
format Online
Article
Text
id pubmed-10013188
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
record_format MEDLINE/PubMed
spelling pubmed-100131882023-03-15 Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic Nunes, Thiago Franchi Inchingolo, Riccardo Kikuti, Cristina Faria de Faria, Bernardo Bacelar Galhardo, Cezar Augusto Vendas Tognini, João Ricardo Filgueiras Marchiori, Edson Hochhegger, Bruno Radiol Bras Original Article OBJECTIVE: To evaluate the diagnostic performance of computed tomography (CT) fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) in pulmonary nodules ≤ 10 mm during the coronavirus disease 2019 pandemic. MATERIALS AND METHODS: Between January 1, 2020 and April 30, 2022, a total of 359 CT fluoroscopy-guided PTNBs were performed at an interventional radiology center. Lung lesions measured between 2 mm and 108 mm. Of the 359 PTNBs, 27 (7.5%) were performed with an 18G core needle on nodules ≤ 10 mm in diameter. RESULTS: Among the 27 biopsies performed on nodules ≤ 10 mm, the lesions measured < 5 mm in four and 5-10 mm in 23. The sensitivity and overall diagnostic accuracy of PTNB were 100% and 92.3%, respectively. The mean dose of ionizing radiation during PTNB was 581.33 mGy*cm (range, 303-1,129 mGy*cm), and the mean biopsy procedure time was 6.6 min (range, 2-12 min). There were no major postprocedural complications. CONCLUSION: CT fluoroscopy-guided PTNB appears to provide a high diagnostic yield with low complication rates. Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2023 /pmc/articles/PMC10013188/ /pubmed/36926361 http://dx.doi.org/10.1590/0100-3984.2022.0062-en Text en https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Nunes, Thiago Franchi
Inchingolo, Riccardo
Kikuti, Cristina Faria
de Faria, Bernardo Bacelar
Galhardo, Cezar Augusto Vendas
Tognini, João Ricardo Filgueiras
Marchiori, Edson
Hochhegger, Bruno
Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic
title Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic
title_full Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic
title_fullStr Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic
title_full_unstemmed Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic
title_short Computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the COVID-19 pandemic
title_sort computed tomography fluoroscopy-guided percutaneous biopsy of pulmonary nodules ≤ 10 mm: retrospective analysis of procedures performed during the covid-19 pandemic
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10013188/
https://www.ncbi.nlm.nih.gov/pubmed/36926361
http://dx.doi.org/10.1590/0100-3984.2022.0062-en
work_keys_str_mv AT nunesthiagofranchi computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic
AT inchingoloriccardo computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic
AT kikuticristinafaria computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic
AT defariabernardobacelar computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic
AT galhardocezaraugustovendas computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic
AT togninijoaoricardofilgueiras computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic
AT marchioriedson computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic
AT hochheggerbruno computedtomographyfluoroscopyguidedpercutaneousbiopsyofpulmonarynodules10mmretrospectiveanalysisofproceduresperformedduringthecovid19pandemic