INTRODUCTION: Therapeutic drug monitoring (TDM) of immunosuppressants is essential for optimal care of transplant patients. Immunoassays and liquid chromatography-mass spectrometry (LC-MS) are the most commonly used methods for TDM. However, immunoassays can suffer from interference from heterophile...

Descripción completa

Detalles Bibliográficos
Autores principales: Yeung, Priscilla S.-W., Miller, Paige, Lai-Nyugen, Tran Bao, Cheng, Phil, Ibrahim, Amira, Shi, Run-Zhang, Bowen, Raffick A.R., Luo, Ruben Yiqi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10014293/
https://www.ncbi.nlm.nih.gov/pubmed/36937810
http://dx.doi.org/10.1016/j.jmsacl.2023.03.002
_version_ 1784906963406028800
author Yeung, Priscilla S.-W.
Miller, Paige
Lai-Nyugen, Tran Bao
Cheng, Phil
Ibrahim, Amira
Shi, Run-Zhang
Bowen, Raffick A.R.
Luo, Ruben Yiqi
author_facet Yeung, Priscilla S.-W.
Miller, Paige
Lai-Nyugen, Tran Bao
Cheng, Phil
Ibrahim, Amira
Shi, Run-Zhang
Bowen, Raffick A.R.
Luo, Ruben Yiqi
author_sort Yeung, Priscilla S.-W.
collection PubMed
description INTRODUCTION: Therapeutic drug monitoring (TDM) of immunosuppressants is essential for optimal care of transplant patients. Immunoassays and liquid chromatography-mass spectrometry (LC-MS) are the most commonly used methods for TDM. However, immunoassays can suffer from interference from heterophile antibodies and structurally similar drugs and metabolites. Additionally, nominal-mass LC-MS assays can be difficult to optimize and are limited in the number of detectable compounds. OBJECTIVES: The aim of this study was to implement a mass spectrometry-based test for immunosuppressant TDM using online solid-phase extraction (SPE) and accurate-mass full scan-single ion monitoring (FS-SIM) data acquisition mode. METHODS: LC-MS analysis was performed on a TLX-2 multi-channel HPLC with a Q-Exactive Plus mass spectrometer. TurboFlow online SPE was used for sample clean up. The accurate-mass MS was set to positive electrospray ionization mode with FS-SIM for quantitation of tacrolimus, sirolimus, everolimus, and cyclosporine A. MS(2) fragmentation pattern was used for compound confirmation. RESULTS: The method was validated in terms of precision, analytical bias, limit of quantitation, linearity, carryover, sample stability, and interference. Quantitation of tacrolimus, sirolimus, everolimus, and cyclosporine A correlated well with results from an independent reference laboratory (r = 0.926–0.984). CONCLUSIONS: Accurate-mass FS-SIM can be successfully utilized for immunosuppressant TDM with good correlation with results generated by standard methods. TurboFlow online SPE allows for a simple “protein crash and shoot” sample preparation protocol. Compared to traditional MRM, analyte quantitation by FS-SIM facilitates a streamlined assay optimization process.
format Online
Article
Text
id pubmed-10014293
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-100142932023-03-16 Mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring Yeung, Priscilla S.-W. Miller, Paige Lai-Nyugen, Tran Bao Cheng, Phil Ibrahim, Amira Shi, Run-Zhang Bowen, Raffick A.R. Luo, Ruben Yiqi J Mass Spectrom Adv Clin Lab Research Article INTRODUCTION: Therapeutic drug monitoring (TDM) of immunosuppressants is essential for optimal care of transplant patients. Immunoassays and liquid chromatography-mass spectrometry (LC-MS) are the most commonly used methods for TDM. However, immunoassays can suffer from interference from heterophile antibodies and structurally similar drugs and metabolites. Additionally, nominal-mass LC-MS assays can be difficult to optimize and are limited in the number of detectable compounds. OBJECTIVES: The aim of this study was to implement a mass spectrometry-based test for immunosuppressant TDM using online solid-phase extraction (SPE) and accurate-mass full scan-single ion monitoring (FS-SIM) data acquisition mode. METHODS: LC-MS analysis was performed on a TLX-2 multi-channel HPLC with a Q-Exactive Plus mass spectrometer. TurboFlow online SPE was used for sample clean up. The accurate-mass MS was set to positive electrospray ionization mode with FS-SIM for quantitation of tacrolimus, sirolimus, everolimus, and cyclosporine A. MS(2) fragmentation pattern was used for compound confirmation. RESULTS: The method was validated in terms of precision, analytical bias, limit of quantitation, linearity, carryover, sample stability, and interference. Quantitation of tacrolimus, sirolimus, everolimus, and cyclosporine A correlated well with results from an independent reference laboratory (r = 0.926–0.984). CONCLUSIONS: Accurate-mass FS-SIM can be successfully utilized for immunosuppressant TDM with good correlation with results generated by standard methods. TurboFlow online SPE allows for a simple “protein crash and shoot” sample preparation protocol. Compared to traditional MRM, analyte quantitation by FS-SIM facilitates a streamlined assay optimization process. Elsevier 2023-03-07 /pmc/articles/PMC10014293/ /pubmed/36937810 http://dx.doi.org/10.1016/j.jmsacl.2023.03.002 Text en © 2023 THE AUTHORS https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Yeung, Priscilla S.-W.
Miller, Paige
Lai-Nyugen, Tran Bao
Cheng, Phil
Ibrahim, Amira
Shi, Run-Zhang
Bowen, Raffick A.R.
Luo, Ruben Yiqi
Mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring
title Mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring
title_full Mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring
title_fullStr Mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring
title_full_unstemmed Mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring
title_short Mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring
title_sort mass spectrometry quantitation of immunosuppressive drugs in clinical specimens using online solid-phase extraction and accurate-mass full scan-single ion monitoring
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10014293/
https://www.ncbi.nlm.nih.gov/pubmed/36937810
http://dx.doi.org/10.1016/j.jmsacl.2023.03.002
work_keys_str_mv AT yeungpriscillasw massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring
AT millerpaige massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring
AT lainyugentranbao massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring
AT chengphil massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring
AT ibrahimamira massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring
AT shirunzhang massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring
AT bowenraffickar massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring
AT luorubenyiqi massspectrometryquantitationofimmunosuppressivedrugsinclinicalspecimensusingonlinesolidphaseextractionandaccuratemassfullscansingleionmonitoring