Cargando…
Evaluation of cannulated compression headless screws as an alternative implant for superior pubic ramus fracture fixation: a biomechanical study
BACKGROUND/PURPOSE: Pubic ramus fractures account for the most common types of pelvic fractures. The standard surgical approach for superior pubic ramus fractures (SPRF) is a minimally invasive percutaneous screw fixation. However, percutaneous closed reduction and internal fixation of anterior pelv...
Autores principales: | Berk, Till, Zderic, Ivan, Schwarzenberg, Peter, Pastor, Tatjana, Lesche, Felix, Halvachizadeh, Sascha, Richards, R. Geoff, Gueorguiev, Boyko, Pape, Hans-Christoph |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10014654/ https://www.ncbi.nlm.nih.gov/pubmed/36749374 http://dx.doi.org/10.1007/s00264-023-05710-3 |
Ejemplares similares
-
Evaluation of Cannulated Compression Headless Screw (CCHS) as an alternative implant in comparison to standard S1-S2 screw fixation of the posterior pelvis ring: a biomechanical study
por: Berk, Till, et al.
Publicado: (2023) -
A Novel Implant for Superior Pubic Ramus Fracture Fixation—Development and a Biomechanical Feasibility Study
por: Berk, Till, et al.
Publicado: (2023) -
Is a Washer a Mandatory Component in Young Trauma Patients with S1-S2 Iliosacral Screw Fixation of Posterior Pelvis Ring Injuries? A Biomechanical Study
por: Berk, Till, et al.
Publicado: (2023) -
Simulated full weight bearing following posterior column acetabular fracture fixation: a biomechanical comparability study
por: Berk, Till, et al.
Publicado: (2023) -
Antegrade Posterior Column Acetabulum Fracture Screw Fixation via Posterior Approach: A Biomechanical Comparative Study
por: Berk, Till, et al.
Publicado: (2023)