Cargando…
Surface Pressures in Lower Extremity Splints: A Biomechanical Study
BACKGROUND: Though ubiquitously used in orthopaedic trauma, lower extremity splints may have associated iatrogenic risk of morbidity. Although clinicians pad bony prominences to minimize skin pressure, the effect of joint position on skin pressure and, more specifically, changing joint position, is...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10014985/ https://www.ncbi.nlm.nih.gov/pubmed/36937805 http://dx.doi.org/10.1177/24730114231160115 |
_version_ | 1784907117005635584 |
---|---|
author | Walley, Kempland C. Farrar, Nicholas Shams, Kameron Anastasio, Albert T. Gong, Davin Mell, Kristopher Holmes, James R. Walton, David M. Talusan, Paul G. |
author_facet | Walley, Kempland C. Farrar, Nicholas Shams, Kameron Anastasio, Albert T. Gong, Davin Mell, Kristopher Holmes, James R. Walton, David M. Talusan, Paul G. |
author_sort | Walley, Kempland C. |
collection | PubMed |
description | BACKGROUND: Though ubiquitously used in orthopaedic trauma, lower extremity splints may have associated iatrogenic risk of morbidity. Although clinicians pad bony prominences to minimize skin pressure, the effect of joint position on skin pressure and, more specifically, changing joint position, is understudied. The purpose of this biomechanical study is to determine the effect of various short-leg splint application techniques on anterior ankle surface pressure in the development of iatrogenic skin pressure ulcers. METHODS: Various constructs of lower extremity, short-leg splints were applied to 3 healthy subjects (6 limbs total) with an underlying pressure transducer (Tekscan I-Scan system) on the skin surface centered on the tibialis anterior tendon at the level of the ankle. All subjects underwent anterior ankle surface pressure assessment when padding was applied in maximum plantar flexion and neutral position for conventional short-leg splints application in clinically relevant patient scenarios. Percentage change from initial contact pressure centered on the tibialis anterior with cast padding were calculated. RESULTS: The percentage change in anterior ankle contact pressure when padding was applied in maximum plantar flexion (PF) and then definitively placed in neutral was increased at least 2-fold without the addition of plaster in lower extremity short-leg splints. Removing anterior ankle padding following final splint application in neutral reduced contact forces at the anterior ankle 46% and 59% in splints applied in maximum PF and neutral ankle position, respectively. CONCLUSION: The present study is the first of its kind to underscore and quantify clinically relevant technical pearls that can be useful in reducing risk of iatrogenic risk of skin breakdown at the anterior ankle when placing short-leg splints, mainly, that it is imperative to apply padding in the intended final splint position and to remove anterior ankle padding following splint application when able. LEVEL OF EVIDENCE: Level IV, biomechanical study with clear hypothesis. |
format | Online Article Text |
id | pubmed-10014985 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-100149852023-03-16 Surface Pressures in Lower Extremity Splints: A Biomechanical Study Walley, Kempland C. Farrar, Nicholas Shams, Kameron Anastasio, Albert T. Gong, Davin Mell, Kristopher Holmes, James R. Walton, David M. Talusan, Paul G. Foot Ankle Orthop Article BACKGROUND: Though ubiquitously used in orthopaedic trauma, lower extremity splints may have associated iatrogenic risk of morbidity. Although clinicians pad bony prominences to minimize skin pressure, the effect of joint position on skin pressure and, more specifically, changing joint position, is understudied. The purpose of this biomechanical study is to determine the effect of various short-leg splint application techniques on anterior ankle surface pressure in the development of iatrogenic skin pressure ulcers. METHODS: Various constructs of lower extremity, short-leg splints were applied to 3 healthy subjects (6 limbs total) with an underlying pressure transducer (Tekscan I-Scan system) on the skin surface centered on the tibialis anterior tendon at the level of the ankle. All subjects underwent anterior ankle surface pressure assessment when padding was applied in maximum plantar flexion and neutral position for conventional short-leg splints application in clinically relevant patient scenarios. Percentage change from initial contact pressure centered on the tibialis anterior with cast padding were calculated. RESULTS: The percentage change in anterior ankle contact pressure when padding was applied in maximum plantar flexion (PF) and then definitively placed in neutral was increased at least 2-fold without the addition of plaster in lower extremity short-leg splints. Removing anterior ankle padding following final splint application in neutral reduced contact forces at the anterior ankle 46% and 59% in splints applied in maximum PF and neutral ankle position, respectively. CONCLUSION: The present study is the first of its kind to underscore and quantify clinically relevant technical pearls that can be useful in reducing risk of iatrogenic risk of skin breakdown at the anterior ankle when placing short-leg splints, mainly, that it is imperative to apply padding in the intended final splint position and to remove anterior ankle padding following splint application when able. LEVEL OF EVIDENCE: Level IV, biomechanical study with clear hypothesis. SAGE Publications 2023-03-13 /pmc/articles/PMC10014985/ /pubmed/36937805 http://dx.doi.org/10.1177/24730114231160115 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Article Walley, Kempland C. Farrar, Nicholas Shams, Kameron Anastasio, Albert T. Gong, Davin Mell, Kristopher Holmes, James R. Walton, David M. Talusan, Paul G. Surface Pressures in Lower Extremity Splints: A Biomechanical Study |
title | Surface Pressures in Lower Extremity Splints: A Biomechanical
Study |
title_full | Surface Pressures in Lower Extremity Splints: A Biomechanical
Study |
title_fullStr | Surface Pressures in Lower Extremity Splints: A Biomechanical
Study |
title_full_unstemmed | Surface Pressures in Lower Extremity Splints: A Biomechanical
Study |
title_short | Surface Pressures in Lower Extremity Splints: A Biomechanical
Study |
title_sort | surface pressures in lower extremity splints: a biomechanical
study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10014985/ https://www.ncbi.nlm.nih.gov/pubmed/36937805 http://dx.doi.org/10.1177/24730114231160115 |
work_keys_str_mv | AT walleykemplandc surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT farrarnicholas surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT shamskameron surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT anastasioalbertt surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT gongdavin surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT mellkristopher surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT holmesjamesr surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT waltondavidm surfacepressuresinlowerextremitysplintsabiomechanicalstudy AT talusanpaulg surfacepressuresinlowerextremitysplintsabiomechanicalstudy |