Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
OBJECTIVES: To predict kidney fibrosis in patients with chronic kidney disease using radiomics of two-dimensional ultrasound (B-mode) and Sound Touch Elastography (STE) images in combination with clinical features. METHODS: The Mindray Resona 7 ultrasonic diagnostic apparatus with SC5-1U convex arra...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10017610/ https://www.ncbi.nlm.nih.gov/pubmed/36454259 http://dx.doi.org/10.1007/s00330-022-09268-3 |
_version_ | 1784907627274174464 |
---|---|
author | Ge, Xin-Yue Lan, Zhong-Kai Lan, Qiao-Qing Lin, Hua-Shan Wang, Guo-Dong Chen, Jing |
author_facet | Ge, Xin-Yue Lan, Zhong-Kai Lan, Qiao-Qing Lin, Hua-Shan Wang, Guo-Dong Chen, Jing |
author_sort | Ge, Xin-Yue |
collection | PubMed |
description | OBJECTIVES: To predict kidney fibrosis in patients with chronic kidney disease using radiomics of two-dimensional ultrasound (B-mode) and Sound Touch Elastography (STE) images in combination with clinical features. METHODS: The Mindray Resona 7 ultrasonic diagnostic apparatus with SC5-1U convex array probe (bandwidth frequency of 1–5 MHz) was used to perform two-dimensional ultrasound and STE software. The severity of cortical tubulointerstitial fibrosis was divided into three grades: mild interstitial fibrosis and tubular atrophy (IFTA), fibrotic area < 25%; moderate IFTA, fibrotic area 26–50%; and severe IFTA, fibrotic area > 50%. After extracting radiomics from B-mode and STE images in these patients, we analyzed two classification schemes: mild versus moderate-to-severe IFTA, and mild-to-moderate versus severe IFTA. A nomogram was constructed based on multiple logistic regression analyses, combining clinical and radiomics. The performance of the nomogram for differentiation was evaluated using receiver operating characteristic (ROC), calibration, and decision curves. RESULTS: A total of 150 patients undergoing kidney biopsy were enrolled (mild IFTA: n = 74; moderate IFTA: n = 33; severe IFTA: n = 43) and randomized into training (n = 105) and validation cohorts (n = 45). To differentiate between mild and moderate-to-severe IFTA, a nomogram incorporating STE radiomics, albumin, and estimated glomerular filtration (eGFR) rate achieved an area under the ROC curve (AUC) of 0.91 (95% confidence interval [CI]: 0.85–0.97) and 0.85 (95% CI: 0.77–0.98) in the training and validation cohorts, respectively. Between mild-to-moderate and severe IFTA, the nomogram incorporating B-mode and STE radiomics features, age, and eGFR achieved an AUC of 0.93 (95% CI: 0.89–0.98) and 0.83 (95% CI: 0.70–0.95) in the training and validation cohorts, respectively. Finally, we performed a decision curve analysis and found that the nomogram using both radiomics and clinical features exhibited better predictability than any other model (DeLong test, p < 0.05 for the training and validation cohorts). CONCLUSION: A nomogram based on two-dimensional ultrasound and STE radiomics and clinical features served as a non-invasive tool capable of differentiating kidney fibrosis of different severities. KEY POINTS: • Radiomics calculated based on the ultrasound imaging may be used to predict the severities of kidney fibrosis. • Radiomics may be used to identify clinical features associated with the progression of tubulointerstitial fibrosis in patients with CKD. • Non-invasive ultrasound imaging-based radiomics method with accuracy aids in detecting renal fibrosis with different IFTA severities. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-022-09268-3. |
format | Online Article Text |
id | pubmed-10017610 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-100176102023-03-17 Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease Ge, Xin-Yue Lan, Zhong-Kai Lan, Qiao-Qing Lin, Hua-Shan Wang, Guo-Dong Chen, Jing Eur Radiol Ultrasound OBJECTIVES: To predict kidney fibrosis in patients with chronic kidney disease using radiomics of two-dimensional ultrasound (B-mode) and Sound Touch Elastography (STE) images in combination with clinical features. METHODS: The Mindray Resona 7 ultrasonic diagnostic apparatus with SC5-1U convex array probe (bandwidth frequency of 1–5 MHz) was used to perform two-dimensional ultrasound and STE software. The severity of cortical tubulointerstitial fibrosis was divided into three grades: mild interstitial fibrosis and tubular atrophy (IFTA), fibrotic area < 25%; moderate IFTA, fibrotic area 26–50%; and severe IFTA, fibrotic area > 50%. After extracting radiomics from B-mode and STE images in these patients, we analyzed two classification schemes: mild versus moderate-to-severe IFTA, and mild-to-moderate versus severe IFTA. A nomogram was constructed based on multiple logistic regression analyses, combining clinical and radiomics. The performance of the nomogram for differentiation was evaluated using receiver operating characteristic (ROC), calibration, and decision curves. RESULTS: A total of 150 patients undergoing kidney biopsy were enrolled (mild IFTA: n = 74; moderate IFTA: n = 33; severe IFTA: n = 43) and randomized into training (n = 105) and validation cohorts (n = 45). To differentiate between mild and moderate-to-severe IFTA, a nomogram incorporating STE radiomics, albumin, and estimated glomerular filtration (eGFR) rate achieved an area under the ROC curve (AUC) of 0.91 (95% confidence interval [CI]: 0.85–0.97) and 0.85 (95% CI: 0.77–0.98) in the training and validation cohorts, respectively. Between mild-to-moderate and severe IFTA, the nomogram incorporating B-mode and STE radiomics features, age, and eGFR achieved an AUC of 0.93 (95% CI: 0.89–0.98) and 0.83 (95% CI: 0.70–0.95) in the training and validation cohorts, respectively. Finally, we performed a decision curve analysis and found that the nomogram using both radiomics and clinical features exhibited better predictability than any other model (DeLong test, p < 0.05 for the training and validation cohorts). CONCLUSION: A nomogram based on two-dimensional ultrasound and STE radiomics and clinical features served as a non-invasive tool capable of differentiating kidney fibrosis of different severities. KEY POINTS: • Radiomics calculated based on the ultrasound imaging may be used to predict the severities of kidney fibrosis. • Radiomics may be used to identify clinical features associated with the progression of tubulointerstitial fibrosis in patients with CKD. • Non-invasive ultrasound imaging-based radiomics method with accuracy aids in detecting renal fibrosis with different IFTA severities. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-022-09268-3. Springer Berlin Heidelberg 2022-12-01 2023 /pmc/articles/PMC10017610/ /pubmed/36454259 http://dx.doi.org/10.1007/s00330-022-09268-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Ultrasound Ge, Xin-Yue Lan, Zhong-Kai Lan, Qiao-Qing Lin, Hua-Shan Wang, Guo-Dong Chen, Jing Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease |
title | Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease |
title_full | Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease |
title_fullStr | Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease |
title_full_unstemmed | Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease |
title_short | Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease |
title_sort | diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease |
topic | Ultrasound |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10017610/ https://www.ncbi.nlm.nih.gov/pubmed/36454259 http://dx.doi.org/10.1007/s00330-022-09268-3 |
work_keys_str_mv | AT gexinyue diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease AT lanzhongkai diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease AT lanqiaoqing diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease AT linhuashan diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease AT wangguodong diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease AT chenjing diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease |