Cargando…

Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease

OBJECTIVES: To predict kidney fibrosis in patients with chronic kidney disease using radiomics of two-dimensional ultrasound (B-mode) and Sound Touch Elastography (STE) images in combination with clinical features. METHODS: The Mindray Resona 7 ultrasonic diagnostic apparatus with SC5-1U convex arra...

Descripción completa

Detalles Bibliográficos
Autores principales: Ge, Xin-Yue, Lan, Zhong-Kai, Lan, Qiao-Qing, Lin, Hua-Shan, Wang, Guo-Dong, Chen, Jing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10017610/
https://www.ncbi.nlm.nih.gov/pubmed/36454259
http://dx.doi.org/10.1007/s00330-022-09268-3
_version_ 1784907627274174464
author Ge, Xin-Yue
Lan, Zhong-Kai
Lan, Qiao-Qing
Lin, Hua-Shan
Wang, Guo-Dong
Chen, Jing
author_facet Ge, Xin-Yue
Lan, Zhong-Kai
Lan, Qiao-Qing
Lin, Hua-Shan
Wang, Guo-Dong
Chen, Jing
author_sort Ge, Xin-Yue
collection PubMed
description OBJECTIVES: To predict kidney fibrosis in patients with chronic kidney disease using radiomics of two-dimensional ultrasound (B-mode) and Sound Touch Elastography (STE) images in combination with clinical features. METHODS: The Mindray Resona 7 ultrasonic diagnostic apparatus with SC5-1U convex array probe (bandwidth frequency of 1–5 MHz) was used to perform two-dimensional ultrasound and STE software. The severity of cortical tubulointerstitial fibrosis was divided into three grades: mild interstitial fibrosis and tubular atrophy (IFTA), fibrotic area < 25%; moderate IFTA, fibrotic area 26–50%; and severe IFTA, fibrotic area > 50%. After extracting radiomics from B-mode and STE images in these patients, we analyzed two classification schemes: mild versus moderate-to-severe IFTA, and mild-to-moderate versus severe IFTA. A nomogram was constructed based on multiple logistic regression analyses, combining clinical and radiomics. The performance of the nomogram for differentiation was evaluated using receiver operating characteristic (ROC), calibration, and decision curves. RESULTS: A total of 150 patients undergoing kidney biopsy were enrolled (mild IFTA: n = 74; moderate IFTA: n = 33; severe IFTA: n = 43) and randomized into training (n = 105) and validation cohorts (n = 45). To differentiate between mild and moderate-to-severe IFTA, a nomogram incorporating STE radiomics, albumin, and estimated glomerular filtration (eGFR) rate achieved an area under the ROC curve (AUC) of 0.91 (95% confidence interval [CI]: 0.85–0.97) and 0.85 (95% CI: 0.77–0.98) in the training and validation cohorts, respectively. Between mild-to-moderate and severe IFTA, the nomogram incorporating B-mode and STE radiomics features, age, and eGFR achieved an AUC of 0.93 (95% CI: 0.89–0.98) and 0.83 (95% CI: 0.70–0.95) in the training and validation cohorts, respectively. Finally, we performed a decision curve analysis and found that the nomogram using both radiomics and clinical features exhibited better predictability than any other model (DeLong test, p < 0.05 for the training and validation cohorts). CONCLUSION: A nomogram based on two-dimensional ultrasound and STE radiomics and clinical features served as a non-invasive tool capable of differentiating kidney fibrosis of different severities. KEY POINTS: • Radiomics calculated based on the ultrasound imaging may be used to predict the severities of kidney fibrosis. • Radiomics may be used to identify clinical features associated with the progression of tubulointerstitial fibrosis in patients with CKD. • Non-invasive ultrasound imaging-based radiomics method with accuracy aids in detecting renal fibrosis with different IFTA severities. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-022-09268-3.
format Online
Article
Text
id pubmed-10017610
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-100176102023-03-17 Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease Ge, Xin-Yue Lan, Zhong-Kai Lan, Qiao-Qing Lin, Hua-Shan Wang, Guo-Dong Chen, Jing Eur Radiol Ultrasound OBJECTIVES: To predict kidney fibrosis in patients with chronic kidney disease using radiomics of two-dimensional ultrasound (B-mode) and Sound Touch Elastography (STE) images in combination with clinical features. METHODS: The Mindray Resona 7 ultrasonic diagnostic apparatus with SC5-1U convex array probe (bandwidth frequency of 1–5 MHz) was used to perform two-dimensional ultrasound and STE software. The severity of cortical tubulointerstitial fibrosis was divided into three grades: mild interstitial fibrosis and tubular atrophy (IFTA), fibrotic area < 25%; moderate IFTA, fibrotic area 26–50%; and severe IFTA, fibrotic area > 50%. After extracting radiomics from B-mode and STE images in these patients, we analyzed two classification schemes: mild versus moderate-to-severe IFTA, and mild-to-moderate versus severe IFTA. A nomogram was constructed based on multiple logistic regression analyses, combining clinical and radiomics. The performance of the nomogram for differentiation was evaluated using receiver operating characteristic (ROC), calibration, and decision curves. RESULTS: A total of 150 patients undergoing kidney biopsy were enrolled (mild IFTA: n = 74; moderate IFTA: n = 33; severe IFTA: n = 43) and randomized into training (n = 105) and validation cohorts (n = 45). To differentiate between mild and moderate-to-severe IFTA, a nomogram incorporating STE radiomics, albumin, and estimated glomerular filtration (eGFR) rate achieved an area under the ROC curve (AUC) of 0.91 (95% confidence interval [CI]: 0.85–0.97) and 0.85 (95% CI: 0.77–0.98) in the training and validation cohorts, respectively. Between mild-to-moderate and severe IFTA, the nomogram incorporating B-mode and STE radiomics features, age, and eGFR achieved an AUC of 0.93 (95% CI: 0.89–0.98) and 0.83 (95% CI: 0.70–0.95) in the training and validation cohorts, respectively. Finally, we performed a decision curve analysis and found that the nomogram using both radiomics and clinical features exhibited better predictability than any other model (DeLong test, p < 0.05 for the training and validation cohorts). CONCLUSION: A nomogram based on two-dimensional ultrasound and STE radiomics and clinical features served as a non-invasive tool capable of differentiating kidney fibrosis of different severities. KEY POINTS: • Radiomics calculated based on the ultrasound imaging may be used to predict the severities of kidney fibrosis. • Radiomics may be used to identify clinical features associated with the progression of tubulointerstitial fibrosis in patients with CKD. • Non-invasive ultrasound imaging-based radiomics method with accuracy aids in detecting renal fibrosis with different IFTA severities. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-022-09268-3. Springer Berlin Heidelberg 2022-12-01 2023 /pmc/articles/PMC10017610/ /pubmed/36454259 http://dx.doi.org/10.1007/s00330-022-09268-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Ultrasound
Ge, Xin-Yue
Lan, Zhong-Kai
Lan, Qiao-Qing
Lin, Hua-Shan
Wang, Guo-Dong
Chen, Jing
Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
title Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
title_full Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
title_fullStr Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
title_full_unstemmed Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
title_short Diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
title_sort diagnostic accuracy of ultrasound-based multimodal radiomics modeling for fibrosis detection in chronic kidney disease
topic Ultrasound
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10017610/
https://www.ncbi.nlm.nih.gov/pubmed/36454259
http://dx.doi.org/10.1007/s00330-022-09268-3
work_keys_str_mv AT gexinyue diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease
AT lanzhongkai diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease
AT lanqiaoqing diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease
AT linhuashan diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease
AT wangguodong diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease
AT chenjing diagnosticaccuracyofultrasoundbasedmultimodalradiomicsmodelingforfibrosisdetectioninchronickidneydisease