Case report: Post-thoracoscopy pendelluft monitoring

Asynchronous alveolar ventilation is called pendelluft, which may induce lung injury in spontaneously breathing patients. We report a case that electrical impedance tomography (EIT) was used to assess the pendelluft in a post-thoracoscopy patient. The pendelluft amplitude was as high as 77.5% of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Zhibin, Zhang, Na, Zhang, Xiajing, Lu, Wenjun, Gao, Changjun, Sun, Xude
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10017850/
https://www.ncbi.nlm.nih.gov/pubmed/36938357
http://dx.doi.org/10.3389/fmed.2022.1108637
Descripción
Sumario:Asynchronous alveolar ventilation is called pendelluft, which may induce lung injury in spontaneously breathing patients. We report a case that electrical impedance tomography (EIT) was used to assess the pendelluft in a post-thoracoscopy patient. The pendelluft amplitude was as high as 77.5% of the tidal variation. The average regional time shift was 0.5 s. The patient was instructed to adjust the breathing method, symptomatic treatment was performed, and the symptoms were improved. This is the first case reporting pendelluft in a post-thoracoscopy patient. Our case demonstrated that (1) pendelluft may occur in post-thoracoscopy patients and it effects lung function, and (2) early identification of affected patients and implementation of corresponding treatments could improve patient outcomes.