Cargando…

Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution

[Image: see text] Particulate matter (PM) air pollution is a major health hazard. The health effects of PM are closely linked to particle size, which governs its deposition in (and penetration through) the respiratory tract. In recent years, low-cost sensors that report particle concentrations for m...

Descripción completa

Detalles Bibliográficos
Autores principales: Molina Rueda, Emilio, Carter, Ellison, L’Orange, Christian, Quinn, Casey, Volckens, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10018765/
https://www.ncbi.nlm.nih.gov/pubmed/36938150
http://dx.doi.org/10.1021/acs.estlett.3c00030
_version_ 1784907882397958144
author Molina Rueda, Emilio
Carter, Ellison
L’Orange, Christian
Quinn, Casey
Volckens, John
author_facet Molina Rueda, Emilio
Carter, Ellison
L’Orange, Christian
Quinn, Casey
Volckens, John
author_sort Molina Rueda, Emilio
collection PubMed
description [Image: see text] Particulate matter (PM) air pollution is a major health hazard. The health effects of PM are closely linked to particle size, which governs its deposition in (and penetration through) the respiratory tract. In recent years, low-cost sensors that report particle concentrations for multiple-sized fractions (PM(1.0), PM(2.5), PM(10)) have proliferated in everyday use and scientific research. However, knowledge of how well these sensors perform across the full range of reported particle size fractions is limited. Unfortunately, erroneous particle size data can lead to spurious conclusions about exposure, misguided interventions, and ineffectual policy decisions. We assessed the linearity, bias, and precision of three low-cost sensor models, as a function of PM size fraction, in an urban setting. Contrary to manufacturers’ claims, sensors are only accurate for the smallest size fraction (PM(1)). The PM(1.0–2.5) and PM(2.5–10) size fractions had large bias, noise, and uncertainty. These results demonstrate that low-cost aerosol sensors (1) cannot discriminate particle size accurately and (2) only report linear and precise measures of aerosol concentration in the accumulation mode size range (i.e., between 0.1 and 1 μm). We recommend that crowdsourced air quality monitoring networks stop reporting coarse (PM(2.5–10)) mode and PM(10) mass concentrations from these sensors.
format Online
Article
Text
id pubmed-10018765
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-100187652023-03-17 Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution Molina Rueda, Emilio Carter, Ellison L’Orange, Christian Quinn, Casey Volckens, John Environ Sci Technol Lett [Image: see text] Particulate matter (PM) air pollution is a major health hazard. The health effects of PM are closely linked to particle size, which governs its deposition in (and penetration through) the respiratory tract. In recent years, low-cost sensors that report particle concentrations for multiple-sized fractions (PM(1.0), PM(2.5), PM(10)) have proliferated in everyday use and scientific research. However, knowledge of how well these sensors perform across the full range of reported particle size fractions is limited. Unfortunately, erroneous particle size data can lead to spurious conclusions about exposure, misguided interventions, and ineffectual policy decisions. We assessed the linearity, bias, and precision of three low-cost sensor models, as a function of PM size fraction, in an urban setting. Contrary to manufacturers’ claims, sensors are only accurate for the smallest size fraction (PM(1)). The PM(1.0–2.5) and PM(2.5–10) size fractions had large bias, noise, and uncertainty. These results demonstrate that low-cost aerosol sensors (1) cannot discriminate particle size accurately and (2) only report linear and precise measures of aerosol concentration in the accumulation mode size range (i.e., between 0.1 and 1 μm). We recommend that crowdsourced air quality monitoring networks stop reporting coarse (PM(2.5–10)) mode and PM(10) mass concentrations from these sensors. American Chemical Society 2023-02-08 /pmc/articles/PMC10018765/ /pubmed/36938150 http://dx.doi.org/10.1021/acs.estlett.3c00030 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Molina Rueda, Emilio
Carter, Ellison
L’Orange, Christian
Quinn, Casey
Volckens, John
Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
title Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
title_full Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
title_fullStr Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
title_full_unstemmed Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
title_short Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
title_sort size-resolved field performance of low-cost sensors for particulate matter air pollution
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10018765/
https://www.ncbi.nlm.nih.gov/pubmed/36938150
http://dx.doi.org/10.1021/acs.estlett.3c00030
work_keys_str_mv AT molinaruedaemilio sizeresolvedfieldperformanceoflowcostsensorsforparticulatematterairpollution
AT carterellison sizeresolvedfieldperformanceoflowcostsensorsforparticulatematterairpollution
AT lorangechristian sizeresolvedfieldperformanceoflowcostsensorsforparticulatematterairpollution
AT quinncasey sizeresolvedfieldperformanceoflowcostsensorsforparticulatematterairpollution
AT volckensjohn sizeresolvedfieldperformanceoflowcostsensorsforparticulatematterairpollution