Cargando…

Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect

Purpose: Proximal tibial fractures are common, but the current available internal fixation strategies remain debatable, especially for comminuted fractures. This study aimed to compare the biomechanical stability of three internal fixation strategies for extra-articular comminuted proximal tibial fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Weihang, Zhao, Ke, Guo, Yuanyuan, Xie, Mao, Feng, Xiaobo, Liu, Ping, Xie, Xin, Fu, Dehao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10020223/
https://www.ncbi.nlm.nih.gov/pubmed/36937755
http://dx.doi.org/10.3389/fbioe.2023.1099241
_version_ 1784908206643871744
author Gao, Weihang
Zhao, Ke
Guo, Yuanyuan
Xie, Mao
Feng, Xiaobo
Liu, Ping
Xie, Xin
Fu, Dehao
author_facet Gao, Weihang
Zhao, Ke
Guo, Yuanyuan
Xie, Mao
Feng, Xiaobo
Liu, Ping
Xie, Xin
Fu, Dehao
author_sort Gao, Weihang
collection PubMed
description Purpose: Proximal tibial fractures are common, but the current available internal fixation strategies remain debatable, especially for comminuted fractures. This study aimed to compare the biomechanical stability of three internal fixation strategies for extra-articular comminuted proximal tibial fractures. Methods: A total of 90 synthetic tibiae models of simulated proximal tibial fractures with segmental bone defects were randomly divided into three groups: Single lateral plating (LP), double plating (DP) and intramedullary nailing (IN). Based on the different number of fixed screws, the above three groups were further divided into nine subgroups and subjected to axial compression, cyclic loading and static torsional testing. Results: The subgroup of intramedullary nailing with five proximal interlocking screws showed the highest axial stiffness of 384.36 ± 35.00 N/mm. The LP group obtained the lowest axial stiffness performance with a value of 96.59 ± 16.14 N/mm. As expected, the DP group offered significantly greater biomechanical stability than the LP group, with mean static axial stiffness and mean torque increasing by approximately 200% and 50%, respectively. According to static torsional experiments, the maximum torque of the DP subgroup was 3,308.32 ± 286.21 N mm, which outperformed all other groups in terms of torsional characteristics. Conclusion: Utilizing more than four distal screws did not provide improved biomechanical stability in the LP or DP groups, while a substantial increase in the biomechanical stability of DP was obtained when an additional medial plate was used. For the intramedullary nailing group, increasing the number of proximal interlocking screws could significantly improve biomechanical stability, and the intramedullary nailing with three proximal interlocking screws had similar static and cyclic stiffness as the DP group. The intramedullary nailing with five proximal screws had better axial stability, whereas DP had better torsional stability.
format Online
Article
Text
id pubmed-10020223
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-100202232023-03-18 Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect Gao, Weihang Zhao, Ke Guo, Yuanyuan Xie, Mao Feng, Xiaobo Liu, Ping Xie, Xin Fu, Dehao Front Bioeng Biotechnol Bioengineering and Biotechnology Purpose: Proximal tibial fractures are common, but the current available internal fixation strategies remain debatable, especially for comminuted fractures. This study aimed to compare the biomechanical stability of three internal fixation strategies for extra-articular comminuted proximal tibial fractures. Methods: A total of 90 synthetic tibiae models of simulated proximal tibial fractures with segmental bone defects were randomly divided into three groups: Single lateral plating (LP), double plating (DP) and intramedullary nailing (IN). Based on the different number of fixed screws, the above three groups were further divided into nine subgroups and subjected to axial compression, cyclic loading and static torsional testing. Results: The subgroup of intramedullary nailing with five proximal interlocking screws showed the highest axial stiffness of 384.36 ± 35.00 N/mm. The LP group obtained the lowest axial stiffness performance with a value of 96.59 ± 16.14 N/mm. As expected, the DP group offered significantly greater biomechanical stability than the LP group, with mean static axial stiffness and mean torque increasing by approximately 200% and 50%, respectively. According to static torsional experiments, the maximum torque of the DP subgroup was 3,308.32 ± 286.21 N mm, which outperformed all other groups in terms of torsional characteristics. Conclusion: Utilizing more than four distal screws did not provide improved biomechanical stability in the LP or DP groups, while a substantial increase in the biomechanical stability of DP was obtained when an additional medial plate was used. For the intramedullary nailing group, increasing the number of proximal interlocking screws could significantly improve biomechanical stability, and the intramedullary nailing with three proximal interlocking screws had similar static and cyclic stiffness as the DP group. The intramedullary nailing with five proximal screws had better axial stability, whereas DP had better torsional stability. Frontiers Media S.A. 2023-03-03 /pmc/articles/PMC10020223/ /pubmed/36937755 http://dx.doi.org/10.3389/fbioe.2023.1099241 Text en Copyright © 2023 Gao, Zhao, Guo, Xie, Feng, Liu, Xie and Fu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Gao, Weihang
Zhao, Ke
Guo, Yuanyuan
Xie, Mao
Feng, Xiaobo
Liu, Ping
Xie, Xin
Fu, Dehao
Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect
title Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect
title_full Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect
title_fullStr Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect
title_full_unstemmed Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect
title_short Biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect
title_sort biomechanical comparison of intramedullary nail and plate osteosynthesis for extra-articular proximal tibial fractures with segmental bone defect
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10020223/
https://www.ncbi.nlm.nih.gov/pubmed/36937755
http://dx.doi.org/10.3389/fbioe.2023.1099241
work_keys_str_mv AT gaoweihang biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect
AT zhaoke biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect
AT guoyuanyuan biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect
AT xiemao biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect
AT fengxiaobo biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect
AT liuping biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect
AT xiexin biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect
AT fudehao biomechanicalcomparisonofintramedullarynailandplateosteosynthesisforextraarticularproximaltibialfractureswithsegmentalbonedefect