Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System

PURPOSE: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. MATERIALS AND METHODS: A retrospective study of patients with femoral neck fractures who underwent internal fix...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Youngho, Shin, Jae-uk, Kim, Sangwoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Hip Society 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10020727/
https://www.ncbi.nlm.nih.gov/pubmed/36937213
http://dx.doi.org/10.5371/hp.2023.35.1.47
_version_ 1784908327905394688
author Cho, Youngho
Shin, Jae-uk
Kim, Sangwoo
author_facet Cho, Youngho
Shin, Jae-uk
Kim, Sangwoo
author_sort Cho, Youngho
collection PubMed
description PURPOSE: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. MATERIALS AND METHODS: A retrospective study of patients with femoral neck fractures who underwent internal fixation and had follow-up of more than six months from 2010 to 2020 was conducted. A total of 87 patients were enrolled in the study. The FNS group included 20 patients and the CS group included 67 patients. Classification of fractures was performed according to Garden and Pauwels classification. Operation time, intraoperative blood loss, sliding distance of the implant, lateral soft tissue irritation caused by implants, and complications were evaluated. RESULTS: The mean operation time was 40.30 minutes in the FNS group and 46.84 minutes in the CS group. The mean intraoperative bleeding volume was 51.25 mL in the FNS group and 72.16 mL in the CS group. Bone union was achieved in 18 patients in the FNS group (90.0%) and in 61 patients in the CS group (91.0%). The mean sliding distance of the implant was 4.06 mm in the FNS group and 3.92 mm in the CS group. No patients in the FNS group and 12 patients in the CS group complained of soft tissue irritation. CONCLUSION: A shorter operative time, less intraoperative bleeding, and less irritation of soft tissue were observed in the FNS group. FNS could be an alternative to CS for fixation of femoral neck fractures.
format Online
Article
Text
id pubmed-10020727
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Korean Hip Society
record_format MEDLINE/PubMed
spelling pubmed-100207272023-03-18 Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System Cho, Youngho Shin, Jae-uk Kim, Sangwoo Hip Pelvis Original Article PURPOSE: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. MATERIALS AND METHODS: A retrospective study of patients with femoral neck fractures who underwent internal fixation and had follow-up of more than six months from 2010 to 2020 was conducted. A total of 87 patients were enrolled in the study. The FNS group included 20 patients and the CS group included 67 patients. Classification of fractures was performed according to Garden and Pauwels classification. Operation time, intraoperative blood loss, sliding distance of the implant, lateral soft tissue irritation caused by implants, and complications were evaluated. RESULTS: The mean operation time was 40.30 minutes in the FNS group and 46.84 minutes in the CS group. The mean intraoperative bleeding volume was 51.25 mL in the FNS group and 72.16 mL in the CS group. Bone union was achieved in 18 patients in the FNS group (90.0%) and in 61 patients in the CS group (91.0%). The mean sliding distance of the implant was 4.06 mm in the FNS group and 3.92 mm in the CS group. No patients in the FNS group and 12 patients in the CS group complained of soft tissue irritation. CONCLUSION: A shorter operative time, less intraoperative bleeding, and less irritation of soft tissue were observed in the FNS group. FNS could be an alternative to CS for fixation of femoral neck fractures. Korean Hip Society 2023-03 2023-03-06 /pmc/articles/PMC10020727/ /pubmed/36937213 http://dx.doi.org/10.5371/hp.2023.35.1.47 Text en Copyright © 2023 by Korean Hip Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Cho, Youngho
Shin, Jae-uk
Kim, Sangwoo
Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System
title Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System
title_full Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System
title_fullStr Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System
title_full_unstemmed Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System
title_short Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System
title_sort comparative study for osteosynthesis of femoral neck fractures: cannulated screws versus femoral neck system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10020727/
https://www.ncbi.nlm.nih.gov/pubmed/36937213
http://dx.doi.org/10.5371/hp.2023.35.1.47
work_keys_str_mv AT choyoungho comparativestudyforosteosynthesisoffemoralneckfracturescannulatedscrewsversusfemoralnecksystem
AT shinjaeuk comparativestudyforosteosynthesisoffemoralneckfracturescannulatedscrewsversusfemoralnecksystem
AT kimsangwoo comparativestudyforosteosynthesisoffemoralneckfracturescannulatedscrewsversusfemoralnecksystem