Cargando…
Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly
PURPOSE: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. MATERIALS AND METHODS: A retrospective re...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Hip Society
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10020729/ https://www.ncbi.nlm.nih.gov/pubmed/36937212 http://dx.doi.org/10.5371/hp.2023.35.1.54 |
Sumario: | PURPOSE: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. MATERIALS AND METHODS: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, three, six, and 12 months and clinical and radiological examinations were performed. RESULTS: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. CONCLUSION: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty. |
---|