Cargando…

Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study

BACKGROUND: Accurate identification of the cricothyroid membrane is crucial for successful cricothyrotomy; however, a manoeuvre that helps identify it both accurately and quickly remains unclear. The effectiveness of the so-called ‘bottom-up manoeuvre’ has never been investigated. This study aimed t...

Descripción completa

Detalles Bibliográficos
Autores principales: Kamikawa, Yohei, Muto, Osamu, Hayashi, Hiroyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10022297/
https://www.ncbi.nlm.nih.gov/pubmed/36927402
http://dx.doi.org/10.1186/s12873-023-00796-9
_version_ 1784908699900313600
author Kamikawa, Yohei
Muto, Osamu
Hayashi, Hiroyuki
author_facet Kamikawa, Yohei
Muto, Osamu
Hayashi, Hiroyuki
author_sort Kamikawa, Yohei
collection PubMed
description BACKGROUND: Accurate identification of the cricothyroid membrane is crucial for successful cricothyrotomy; however, a manoeuvre that helps identify it both accurately and quickly remains unclear. The effectiveness of the so-called ‘bottom-up manoeuvre’ has never been investigated. This study aimed to examine whether the bottom-up manoeuvre is as rapid and accurate as the conventional ‘top-down manoeuvre’ at identifying the cricothyroid membrane. METHODS: This study was a prospective randomised cross-over trial conducted at an academic medical centre between 2018 and 2019. Fifth-year medical students participated. The students were trained in the use of either the top-down manoeuvre or the bottom-up manoeuvre first. Each student subsequently performed the technique once on a volunteer. The students were then taught and practiced the other manoeuvre as well. The accuracy of cricothyroid membrane identification and the time taken by successful participants only were measured and compared between the manoeuvres using equivalence tests with two one-sided tests. RESULTS: A total of 102 medical students participated in this study and there was no missing data. The accuracy of identification and time required for success were similar between the top-down manoeuvre and the bottom-up manoeuvre (65.7% vs. 70.6%, taking 13.8 s [interquartile range (IQR): 9.4–17.5] vs. 15.5 s [IQR: 11.5–19.9], respectively). The success rate was statistically equivalent (rate difference, 4.9%; 90% confidence interval [CI], -5.8 to 15.6; equivalence margin, -20.0 to 20.0). The time required for success was also statistically equivalent (median difference, 1.7 s; 90% CI, -0.2 to 3.3; equivalence margin, -4.0 to 4.0). CONCLUSION: Among students first trained in both manoeuvres for identifying the cricothyroid membrane, the speed and accuracy of identification were similar between those using the bottom-up manoeuvre and those using the top-down manoeuvre.
format Online
Article
Text
id pubmed-10022297
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-100222972023-03-18 Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study Kamikawa, Yohei Muto, Osamu Hayashi, Hiroyuki BMC Emerg Med Research BACKGROUND: Accurate identification of the cricothyroid membrane is crucial for successful cricothyrotomy; however, a manoeuvre that helps identify it both accurately and quickly remains unclear. The effectiveness of the so-called ‘bottom-up manoeuvre’ has never been investigated. This study aimed to examine whether the bottom-up manoeuvre is as rapid and accurate as the conventional ‘top-down manoeuvre’ at identifying the cricothyroid membrane. METHODS: This study was a prospective randomised cross-over trial conducted at an academic medical centre between 2018 and 2019. Fifth-year medical students participated. The students were trained in the use of either the top-down manoeuvre or the bottom-up manoeuvre first. Each student subsequently performed the technique once on a volunteer. The students were then taught and practiced the other manoeuvre as well. The accuracy of cricothyroid membrane identification and the time taken by successful participants only were measured and compared between the manoeuvres using equivalence tests with two one-sided tests. RESULTS: A total of 102 medical students participated in this study and there was no missing data. The accuracy of identification and time required for success were similar between the top-down manoeuvre and the bottom-up manoeuvre (65.7% vs. 70.6%, taking 13.8 s [interquartile range (IQR): 9.4–17.5] vs. 15.5 s [IQR: 11.5–19.9], respectively). The success rate was statistically equivalent (rate difference, 4.9%; 90% confidence interval [CI], -5.8 to 15.6; equivalence margin, -20.0 to 20.0). The time required for success was also statistically equivalent (median difference, 1.7 s; 90% CI, -0.2 to 3.3; equivalence margin, -4.0 to 4.0). CONCLUSION: Among students first trained in both manoeuvres for identifying the cricothyroid membrane, the speed and accuracy of identification were similar between those using the bottom-up manoeuvre and those using the top-down manoeuvre. BioMed Central 2023-03-16 /pmc/articles/PMC10022297/ /pubmed/36927402 http://dx.doi.org/10.1186/s12873-023-00796-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kamikawa, Yohei
Muto, Osamu
Hayashi, Hiroyuki
Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study
title Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study
title_full Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study
title_fullStr Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study
title_full_unstemmed Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study
title_short Equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study
title_sort equivalence of the top-down manoeuvre and bottom-up manoeuvre in speed and accuracy of identifying the cricothyroid membrane: a prospective randomised cross-over study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10022297/
https://www.ncbi.nlm.nih.gov/pubmed/36927402
http://dx.doi.org/10.1186/s12873-023-00796-9
work_keys_str_mv AT kamikawayohei equivalenceofthetopdownmanoeuvreandbottomupmanoeuvreinspeedandaccuracyofidentifyingthecricothyroidmembraneaprospectiverandomisedcrossoverstudy
AT mutoosamu equivalenceofthetopdownmanoeuvreandbottomupmanoeuvreinspeedandaccuracyofidentifyingthecricothyroidmembraneaprospectiverandomisedcrossoverstudy
AT hayashihiroyuki equivalenceofthetopdownmanoeuvreandbottomupmanoeuvreinspeedandaccuracyofidentifyingthecricothyroidmembraneaprospectiverandomisedcrossoverstudy