DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS
Intensity modulated radiotherapy (IMRT) has become widely used as a standard radiation therapy technique for the treatment of localized prostate cancer. The transition from conformal radiotherapy (3D CRT) to a more complex IMRT technique triggered the need for more thorough verification of the accur...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sestre Milosrdnice University Hospital and Institute of Clinical Medical Research, Vinogradska cesta c. 29 Zagreb
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10022411/ https://www.ncbi.nlm.nih.gov/pubmed/36938551 http://dx.doi.org/10.20471/acc.2022.61.s3.3 |
_version_ | 1784908725780217856 |
---|---|
author | Mrčela, Iva Gregov, Marin Matanić, Ante Budanec, Mirjana Murgić, Jure Jakšić, Blanka Prpić, Marin Prgomet Sečan, Angela Frobe, Ana |
author_facet | Mrčela, Iva Gregov, Marin Matanić, Ante Budanec, Mirjana Murgić, Jure Jakšić, Blanka Prpić, Marin Prgomet Sečan, Angela Frobe, Ana |
author_sort | Mrčela, Iva |
collection | PubMed |
description | Intensity modulated radiotherapy (IMRT) has become widely used as a standard radiation therapy technique for the treatment of localized prostate cancer. The transition from conformal radiotherapy (3D CRT) to a more complex IMRT technique triggered the need for more thorough verification of the accuracy in the dose delivery. In this work we present the clinical workflow and the results of patient specific quality assurance (PSQA) procedures for 40 prostate cancer patients who have been treated with step and shot IMRT ever since its implementation in our routine clinical practice. PSQA procedures include dosimetric verification of each treatment plan with dedicated rotational phantom and high-resolution matrix detector system Octavius 4D (PTW Freiburg) that allows three-dimensional comparison of the calculated and delivered radiation dose distribution. Our results proved the compliance with the universal tolerance limits recommended for those procedures (1), assuring the safety of the treatment and providing the possibility for the adoption of more stringent constraints in the future. |
format | Online Article Text |
id | pubmed-10022411 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Sestre Milosrdnice University Hospital and Institute of Clinical Medical Research, Vinogradska cesta c. 29 Zagreb |
record_format | MEDLINE/PubMed |
spelling | pubmed-100224112023-03-18 DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS Mrčela, Iva Gregov, Marin Matanić, Ante Budanec, Mirjana Murgić, Jure Jakšić, Blanka Prpić, Marin Prgomet Sečan, Angela Frobe, Ana Acta Clin Croat Original Scientific Papers Intensity modulated radiotherapy (IMRT) has become widely used as a standard radiation therapy technique for the treatment of localized prostate cancer. The transition from conformal radiotherapy (3D CRT) to a more complex IMRT technique triggered the need for more thorough verification of the accuracy in the dose delivery. In this work we present the clinical workflow and the results of patient specific quality assurance (PSQA) procedures for 40 prostate cancer patients who have been treated with step and shot IMRT ever since its implementation in our routine clinical practice. PSQA procedures include dosimetric verification of each treatment plan with dedicated rotational phantom and high-resolution matrix detector system Octavius 4D (PTW Freiburg) that allows three-dimensional comparison of the calculated and delivered radiation dose distribution. Our results proved the compliance with the universal tolerance limits recommended for those procedures (1), assuring the safety of the treatment and providing the possibility for the adoption of more stringent constraints in the future. Sestre Milosrdnice University Hospital and Institute of Clinical Medical Research, Vinogradska cesta c. 29 Zagreb 2022-10 /pmc/articles/PMC10022411/ /pubmed/36938551 http://dx.doi.org/10.20471/acc.2022.61.s3.3 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND) 4.0 License. |
spellingShingle | Original Scientific Papers Mrčela, Iva Gregov, Marin Matanić, Ante Budanec, Mirjana Murgić, Jure Jakšić, Blanka Prpić, Marin Prgomet Sečan, Angela Frobe, Ana DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS |
title | DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS |
title_full | DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS |
title_fullStr | DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS |
title_full_unstemmed | DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS |
title_short | DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY (IMRT) TREATMENT PLANS FOR PROSTATE CANCER PATIENTS |
title_sort | dosimetric verification of intensity modulated radiotherapy (imrt) treatment plans for prostate cancer patients |
topic | Original Scientific Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10022411/ https://www.ncbi.nlm.nih.gov/pubmed/36938551 http://dx.doi.org/10.20471/acc.2022.61.s3.3 |
work_keys_str_mv | AT mrcelaiva dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT gregovmarin dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT matanicante dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT budanecmirjana dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT murgicjure dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT jaksicblanka dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT prpicmarin dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT prgometsecanangela dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients AT frobeana dosimetricverificationofintensitymodulatedradiotherapyimrttreatmentplansforprostatecancerpatients |