Cargando…

Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts

BACKGROUND: Percutaneous coronary interventions (PCIs) within left main coronary arteries are high-risk procedures that require optimization of interactions between stent(s) and diseased vessels. Optical Coherence Tomography (OCT) is a widely accepted tool that enhances physicians’ ability to assess...

Descripción completa

Detalles Bibliográficos
Autores principales: Valenzuela, Thomas F., Iaizzo, Paul A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10024839/
https://www.ncbi.nlm.nih.gov/pubmed/36934270
http://dx.doi.org/10.1186/s12938-023-01090-2
_version_ 1784909196182945792
author Valenzuela, Thomas F.
Iaizzo, Paul A.
author_facet Valenzuela, Thomas F.
Iaizzo, Paul A.
author_sort Valenzuela, Thomas F.
collection PubMed
description BACKGROUND: Percutaneous coronary interventions (PCIs) within left main coronary arteries are high-risk procedures that require optimization of interactions between stent(s) and diseased vessels. Optical Coherence Tomography (OCT) is a widely accepted tool that enhances physicians’ ability to assess proper stent appositions during clinical procedures. The primary aim of this study was to develop complementary post-procedure imaging methodologies to better assess and interpret outcomes of left main PCI procedures, utilizing both reanimated and perfusion-fixed human hearts. METHODS: PCIs were performed while obtaining OCT scans within the left main anatomies of six human hearts. Subsequently, each heart was scanned with a micro-CT scanner with optimized parameters to achieve resolutions up to 20 µm. Scans were reconstructed and imported into a DICOM segmentation software to generate computational models of implanted stents and associated coronary vessels. 2D images from OCT that were obtained during PCIs were compared to the 3D models generated from micro-CT reconstructions. In addition, the 3D models were utilized to create virtual reality scenes and enlarged 3D prints for development of “mixed reality” tools relative to bifurcation stenting within human left main coronary arteries. RESULTS: We developed reproducible methodologies for post-implant analyses of coronary artery stenting procedures. In addition, we generated high-resolution 3D computational models, with ~ 20-micron resolutions, of PCIs performed within reanimated and perfusion-fixed heart specimens. CONCLUSIONS: Generated computational models of left main PCIs performed in isolated human hearts can be used to obtain detailed measurements that provide further clinical insights on procedural outcomes. The 3D models from these procedures are useful for generating virtual reality scenes and 3D prints for physician training and education.
format Online
Article
Text
id pubmed-10024839
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-100248392023-03-20 Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts Valenzuela, Thomas F. Iaizzo, Paul A. Biomed Eng Online Research BACKGROUND: Percutaneous coronary interventions (PCIs) within left main coronary arteries are high-risk procedures that require optimization of interactions between stent(s) and diseased vessels. Optical Coherence Tomography (OCT) is a widely accepted tool that enhances physicians’ ability to assess proper stent appositions during clinical procedures. The primary aim of this study was to develop complementary post-procedure imaging methodologies to better assess and interpret outcomes of left main PCI procedures, utilizing both reanimated and perfusion-fixed human hearts. METHODS: PCIs were performed while obtaining OCT scans within the left main anatomies of six human hearts. Subsequently, each heart was scanned with a micro-CT scanner with optimized parameters to achieve resolutions up to 20 µm. Scans were reconstructed and imported into a DICOM segmentation software to generate computational models of implanted stents and associated coronary vessels. 2D images from OCT that were obtained during PCIs were compared to the 3D models generated from micro-CT reconstructions. In addition, the 3D models were utilized to create virtual reality scenes and enlarged 3D prints for development of “mixed reality” tools relative to bifurcation stenting within human left main coronary arteries. RESULTS: We developed reproducible methodologies for post-implant analyses of coronary artery stenting procedures. In addition, we generated high-resolution 3D computational models, with ~ 20-micron resolutions, of PCIs performed within reanimated and perfusion-fixed heart specimens. CONCLUSIONS: Generated computational models of left main PCIs performed in isolated human hearts can be used to obtain detailed measurements that provide further clinical insights on procedural outcomes. The 3D models from these procedures are useful for generating virtual reality scenes and 3D prints for physician training and education. BioMed Central 2023-03-18 /pmc/articles/PMC10024839/ /pubmed/36934270 http://dx.doi.org/10.1186/s12938-023-01090-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Valenzuela, Thomas F.
Iaizzo, Paul A.
Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts
title Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts
title_full Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts
title_fullStr Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts
title_full_unstemmed Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts
title_short Post-procedure micro-CT analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts
title_sort post-procedure micro-ct analyses of coronary artery stenting in left main vessels of reanimated and perfusion-fixed human hearts
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10024839/
https://www.ncbi.nlm.nih.gov/pubmed/36934270
http://dx.doi.org/10.1186/s12938-023-01090-2
work_keys_str_mv AT valenzuelathomasf postproceduremicroctanalysesofcoronaryarterystentinginleftmainvesselsofreanimatedandperfusionfixedhumanhearts
AT iaizzopaula postproceduremicroctanalysesofcoronaryarterystentinginleftmainvesselsofreanimatedandperfusionfixedhumanhearts