Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL
PURPOSE: To analyze the objective and subjective visual performances of a new hybrid refractive/aspheric extended depth of focus (EDOF) intraocular lens (IOL). METHODS: In this monocentric prospective study patients with bilateral cataracts underwent cataract surgery and were implanted with a Lucidi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10025297/ https://www.ncbi.nlm.nih.gov/pubmed/36950509 http://dx.doi.org/10.3389/fmed.2023.1085280 |
_version_ | 1784909298108727296 |
---|---|
author | Pedrotti, Emilio Bonacci, Erika Kilian, Raphael Pagnacco, Camilla Anastasi, Marco Ventura, Mariacarmela Marchini, Giorgio |
author_facet | Pedrotti, Emilio Bonacci, Erika Kilian, Raphael Pagnacco, Camilla Anastasi, Marco Ventura, Mariacarmela Marchini, Giorgio |
author_sort | Pedrotti, Emilio |
collection | PubMed |
description | PURPOSE: To analyze the objective and subjective visual performances of a new hybrid refractive/aspheric extended depth of focus (EDOF) intraocular lens (IOL). METHODS: In this monocentric prospective study patients with bilateral cataracts underwent cataract surgery and were implanted with a Lucidis IOL (SAV-IOL SA, Neuchâtel, Switzerland) in both eyes, 1 week apart from each other. At 3 months from implantation postoperative evaluations included monocular and binocular uncorrected and distance-corrected distant (4 m), intermediate (80 cm, 67 cm) and near (40 cm) visual acuities (UDVA/DCVA, UI80-67VA/DCI80-67VA, UNVA/DCNVA), binocular defocus curves, halometry, contrast sensitivity and objective quality-of-vision measurements. Also, patients were also asked to complete the national eye institute refractive error quality of life (NEI-RQL-42) questionnaire. RESULTS: Twenty-five patients (50 eyes) were included. The mean postoperative binocular UDVA, UI80VA, UI67VA and UNVA were-0.02 ± 0.13, 0.05 ± 0.09, 0.05 ± 0.08 and 0.03 ± 0.1 LogMar, and did not significantly differ from their corrected counterparts. On binocular defocus curves a VA ≥0.05LogMar was found between +0.50 and − 2.50 D of vergence, whereas the mean distance from the central stimulus on halometry was 1.23 ± 0.01. Mean ocular and corneal radical mean square at 4 mm were 0.31 ± 0.28 and 0.19 ± 0.07, respectively; whereas the mean Strehl ratio was 0.2 ± 0.09. CONCLUSION: Lucidis IOLs demonstrated excellent visual performances, especially at close distances while maintain good quality of vision, contrast sensitivity, and overall patient-satisfaction. |
format | Online Article Text |
id | pubmed-10025297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100252972023-03-21 Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL Pedrotti, Emilio Bonacci, Erika Kilian, Raphael Pagnacco, Camilla Anastasi, Marco Ventura, Mariacarmela Marchini, Giorgio Front Med (Lausanne) Medicine PURPOSE: To analyze the objective and subjective visual performances of a new hybrid refractive/aspheric extended depth of focus (EDOF) intraocular lens (IOL). METHODS: In this monocentric prospective study patients with bilateral cataracts underwent cataract surgery and were implanted with a Lucidis IOL (SAV-IOL SA, Neuchâtel, Switzerland) in both eyes, 1 week apart from each other. At 3 months from implantation postoperative evaluations included monocular and binocular uncorrected and distance-corrected distant (4 m), intermediate (80 cm, 67 cm) and near (40 cm) visual acuities (UDVA/DCVA, UI80-67VA/DCI80-67VA, UNVA/DCNVA), binocular defocus curves, halometry, contrast sensitivity and objective quality-of-vision measurements. Also, patients were also asked to complete the national eye institute refractive error quality of life (NEI-RQL-42) questionnaire. RESULTS: Twenty-five patients (50 eyes) were included. The mean postoperative binocular UDVA, UI80VA, UI67VA and UNVA were-0.02 ± 0.13, 0.05 ± 0.09, 0.05 ± 0.08 and 0.03 ± 0.1 LogMar, and did not significantly differ from their corrected counterparts. On binocular defocus curves a VA ≥0.05LogMar was found between +0.50 and − 2.50 D of vergence, whereas the mean distance from the central stimulus on halometry was 1.23 ± 0.01. Mean ocular and corneal radical mean square at 4 mm were 0.31 ± 0.28 and 0.19 ± 0.07, respectively; whereas the mean Strehl ratio was 0.2 ± 0.09. CONCLUSION: Lucidis IOLs demonstrated excellent visual performances, especially at close distances while maintain good quality of vision, contrast sensitivity, and overall patient-satisfaction. Frontiers Media S.A. 2023-03-06 /pmc/articles/PMC10025297/ /pubmed/36950509 http://dx.doi.org/10.3389/fmed.2023.1085280 Text en Copyright © 2023 Pedrotti, Bonacci, Kilian, Pagnacco, Anastasi, Ventura and Marchini. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Pedrotti, Emilio Bonacci, Erika Kilian, Raphael Pagnacco, Camilla Anastasi, Marco Ventura, Mariacarmela Marchini, Giorgio Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL |
title | Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL |
title_full | Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL |
title_fullStr | Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL |
title_full_unstemmed | Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL |
title_short | Quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam IOL |
title_sort | quality of vision and outcomes after bilateral implantation of pseudo-non diffracting beam iol |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10025297/ https://www.ncbi.nlm.nih.gov/pubmed/36950509 http://dx.doi.org/10.3389/fmed.2023.1085280 |
work_keys_str_mv | AT pedrottiemilio qualityofvisionandoutcomesafterbilateralimplantationofpseudonondiffractingbeamiol AT bonaccierika qualityofvisionandoutcomesafterbilateralimplantationofpseudonondiffractingbeamiol AT kilianraphael qualityofvisionandoutcomesafterbilateralimplantationofpseudonondiffractingbeamiol AT pagnaccocamilla qualityofvisionandoutcomesafterbilateralimplantationofpseudonondiffractingbeamiol AT anastasimarco qualityofvisionandoutcomesafterbilateralimplantationofpseudonondiffractingbeamiol AT venturamariacarmela qualityofvisionandoutcomesafterbilateralimplantationofpseudonondiffractingbeamiol AT marchinigiorgio qualityofvisionandoutcomesafterbilateralimplantationofpseudonondiffractingbeamiol |