Cargando…

Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study

BACKGROUND: This study aims to investigate whether indocyanine green (ICG) tumor imaging helps determine the safe surgical margin in laparoscopic hepatectomy. PATIENTS AND METHODS: Eighty-six patients with hepatic malignancies [including hepatocellular carcinoma (HCC) and colorectal liver metastasis...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Xinran, Hong, Haijie, Pan, Wei, Chen, Jiangzhi, Jiang, Lei, Du, Qiang, Li, Ge, Lin, Shengzhe, Chen, Yanling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027791/
https://www.ncbi.nlm.nih.gov/pubmed/36484905
http://dx.doi.org/10.1245/s10434-022-12893-3
_version_ 1784909789580492800
author Cai, Xinran
Hong, Haijie
Pan, Wei
Chen, Jiangzhi
Jiang, Lei
Du, Qiang
Li, Ge
Lin, Shengzhe
Chen, Yanling
author_facet Cai, Xinran
Hong, Haijie
Pan, Wei
Chen, Jiangzhi
Jiang, Lei
Du, Qiang
Li, Ge
Lin, Shengzhe
Chen, Yanling
author_sort Cai, Xinran
collection PubMed
description BACKGROUND: This study aims to investigate whether indocyanine green (ICG) tumor imaging helps determine the safe surgical margin in laparoscopic hepatectomy. PATIENTS AND METHODS: Eighty-six patients with hepatic malignancies [including hepatocellular carcinoma (HCC) and colorectal liver metastasis (CRLM)] were included in this study. ICG-R15 testing was performed 5–7 days before surgery. Fluorescence staining of the tumor was detected by a fluorescent laparoscope, and the width of fluorescence band surrounding tumor was measured by an electronic vernier caliper. RESULTS: The positive rate of hepatic malignant lesions successfully stained by ICG fluorescence was 96.0% (95/99). HCC with better differentiation demonstrated non-rim fluorescence patterns, while cases with poor differentiation demonstrated rim patterns. CRLM uniformly demonstrated rim pattern. The width of fluorescence surrounding tumors was 0 in HCC with non-rim patterns. The minimum width of fluorescence surrounding tumors in poor differentiated HCC and CRLM were 2.4 ± 1.9 mm and 2.8 ± 2.5 mm, respectively, with no significant difference (P > 0.05). ICG fluorescence imaging revealed eight small lesions, which were not detected preoperatively in seven patients, of which five lesions were confirmed as malignancies by pathology. CONCLUSIONS: Resection along the ICG fluorescence edge can supply a safe surgical margin only for CRLM, but not for HCC. Otherwise, ICG fluorescence tumor imaging can preliminarily determine the pathological type of hepatic malignancies and histological differentiation of HCC and help detect small lesions that cannot be detected preoperatively.
format Online
Article
Text
id pubmed-10027791
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-100277912023-03-22 Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study Cai, Xinran Hong, Haijie Pan, Wei Chen, Jiangzhi Jiang, Lei Du, Qiang Li, Ge Lin, Shengzhe Chen, Yanling Ann Surg Oncol Hepatobiliary Tumors BACKGROUND: This study aims to investigate whether indocyanine green (ICG) tumor imaging helps determine the safe surgical margin in laparoscopic hepatectomy. PATIENTS AND METHODS: Eighty-six patients with hepatic malignancies [including hepatocellular carcinoma (HCC) and colorectal liver metastasis (CRLM)] were included in this study. ICG-R15 testing was performed 5–7 days before surgery. Fluorescence staining of the tumor was detected by a fluorescent laparoscope, and the width of fluorescence band surrounding tumor was measured by an electronic vernier caliper. RESULTS: The positive rate of hepatic malignant lesions successfully stained by ICG fluorescence was 96.0% (95/99). HCC with better differentiation demonstrated non-rim fluorescence patterns, while cases with poor differentiation demonstrated rim patterns. CRLM uniformly demonstrated rim pattern. The width of fluorescence surrounding tumors was 0 in HCC with non-rim patterns. The minimum width of fluorescence surrounding tumors in poor differentiated HCC and CRLM were 2.4 ± 1.9 mm and 2.8 ± 2.5 mm, respectively, with no significant difference (P > 0.05). ICG fluorescence imaging revealed eight small lesions, which were not detected preoperatively in seven patients, of which five lesions were confirmed as malignancies by pathology. CONCLUSIONS: Resection along the ICG fluorescence edge can supply a safe surgical margin only for CRLM, but not for HCC. Otherwise, ICG fluorescence tumor imaging can preliminarily determine the pathological type of hepatic malignancies and histological differentiation of HCC and help detect small lesions that cannot be detected preoperatively. Springer International Publishing 2022-12-09 2023 /pmc/articles/PMC10027791/ /pubmed/36484905 http://dx.doi.org/10.1245/s10434-022-12893-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Hepatobiliary Tumors
Cai, Xinran
Hong, Haijie
Pan, Wei
Chen, Jiangzhi
Jiang, Lei
Du, Qiang
Li, Ge
Lin, Shengzhe
Chen, Yanling
Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
title Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
title_full Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
title_fullStr Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
title_full_unstemmed Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
title_short Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
title_sort does using indocyanine green fluorescence imaging for tumors help in determining the safe surgical margin in real-time navigation of laparoscopic hepatectomy? a retrospective study
topic Hepatobiliary Tumors
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027791/
https://www.ncbi.nlm.nih.gov/pubmed/36484905
http://dx.doi.org/10.1245/s10434-022-12893-3
work_keys_str_mv AT caixinran doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT honghaijie doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT panwei doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT chenjiangzhi doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT jianglei doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT duqiang doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT lige doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT linshengzhe doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy
AT chenyanling doesusingindocyaninegreenfluorescenceimagingfortumorshelpindeterminingthesafesurgicalmargininrealtimenavigationoflaparoscopichepatectomyaretrospectivestudy